Grundfos TPE3 40-200 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Composite Impeller
SKU: 99272211

Grundfos TPE3 40-200 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Composite Impeller

$6,380.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
342 L/Min
Max Head
14.9 m
Power
1.1 kW / 415v
Ideal Use
Heating & Cooling Systems

Product Overview

Operating on a 1.1 kW motor drive, the TPE3 40-200 single-stage inline pump handles fluid transfer across commercial building services, cooling tower circuits, and hydronic heating headers. Standardized DN 40 suction and discharge flanges permit inline line mounting, eliminating complex foundation coupling procedures.

Liquid handling performance provides a nominal flow rate of 342 L/Min against a maximum head limit of 14.9 m. The cast iron volute body (EN-GJL-250) offers corrosion barrier protection for hydronic loops. The internal rotor houses a Composite impeller assembly supported by a BQQE shaft seal. Equipment net weight stands at 24.8 kg.

Engineered for Three-phase electrical systems (3 x 380-500 V), the 1.1 kW motor draws 2.3 Amps full-load current. Operating liquid temperatures cover a wide -25°C to 120°C span up to 16 bar system working pressure. Opposite DN 40 inlet and DN 40 discharge flanges provide standard pipe header compatibility.

Enclosure protection meets IP55 weatherization standards, supported by Class F motor insulation against high ambient temperatures. An onboard frequency converter with closed-loop PI control allows real-time variable speed tuning. The top-pull-out power head geometry permits technicians to perform seal or impeller maintenance while keeping the volute casing installed in system pipework headers.

Features

  • Equal suction and discharge port diameters enable straightforward inline installation without requiring custom pipe reducer spools.
  • Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
  • Top-pull-out structural layout enables complete drive head and impeller extraction without disconnecting the pump casing from system piping.
  • High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.
  • EN-GJL-250 cast iron volute housing provides robust pressure containment up to 16 bar in demanding hydronic circulation loops.
  • Corrosion-resistant Composite impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
  • Standardized DN 40 flanged connections comply with EN 1092-2 for seamless drop-in integration into commercial pipe headers.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow342 L/Min
Max Head14.9 m
Power1.1 kW / 415v
Rated Current2.3 Amps
Suitable ForHeating & Cooling Systems
Body MaterialEN-GJL-250 Cast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size40 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download

Multi-zone radiator circuits in energy-efficient buildings deploy The Grundfos TPE3 40-200 to achieve automated hydraulic balancing. Variable-speed motor technology eliminates excessive line pressure, preventing water velocity noise through occupied building areas.

  • Multi-Zone Radiators
  • Automated Balancing
  • Energy Efficient Buildings
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Through automated variable speed adjustment, what total vertical column does this booster attain?

Variable speed motor control enables Grundfos TPE3 40-200 to achieve a peak dynamic elevation of approximately 14.9 m.

With integrated speed regulation, what maximum fluid circulation volume is delivered on site?

Automated variable flow regulation enables TPE3 40-200 to deliver a maximum volumetric throughput of approximately 342 L/Min.

How do the electrocoated volute and balanced impeller maintain long-term physical integrity?

Corrosion defense in TPE3-40-200 is achieved with cataphoresis-treated cast iron paired with an engineered composite impeller (PES-GF30).

Under electronic inverter drive control, what motor kilowatts, line voltage, and amps are required?

Electrical specifications certified for TPE3 40 200 include a 1.1 kW variable drive running on a three-phase 415 V line at 2.3 Amps.

Regarding media conditions, what minimum and maximum fluid temperatures can this pump sustain?

Media circulating through TPE3/40/200 can range from -25°C to 120°C under maximum permissible working pressures of 16 bar.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed