Product Overview
Built for continuous duty in hydronic climate control networks and facility water loops, the TPE3 65-280 inline centrifugal pump combines a 3 kW electric motor with close-coupled in-line architecture. Suction and discharge connections feature identical DN 65 porting, enabling direct drop-in placement within mechanical room pipe headers.
The hydraulic wet-end is engineered for optimal fluid dynamics, delivering 773 L/Min rated flow volume and reaching a maximum head capacity of 19.3 m. Cast iron housing materials (EN-GJL-250) provide reliable pressure containment under continuous duty cycles. A Composite impeller and BQQE seal drive liquid media across wetted passages. Net product weight measures 54.1 kg.
Configured for 3 x 380-500 V Three-phase power lines, the 3 kW drive motor draws 5.80 Amps during nominal full-load duty. Thermal operational limits support fluid handling from -25°C to 120°C across commercial hydronic networks. Connection to plant room headers relies on inline DN 65 suction and DN 65 discharge flanges.
Winding insulation complies with Class F standards within an IP55 rated motor enclosure designed for demanding plant room environments. Equipped with an onboard frequency converter and PI controller, the pump modulates motor RPM dynamically for maximum energy efficiency. Top-pull-out casing construction enables service personnel to extract drive components without disconnecting suction or discharge flanges.
Features
- Class F thermal motor insulation permits continuous operation under elevated fluid temperatures ranging from -25°C to 120°C.
- Equal suction and discharge port diameters enable straightforward inline installation without requiring custom pipe reducer spools.
- Integrated variable frequency converter with PI controller modulates motor RPM dynamically to balance flow demand and lower energy usage.
- Top-pull-out structural layout enables complete drive head and impeller extraction without disconnecting the pump casing from system piping.
- High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.
- EN-GJL-250 cast iron volute housing provides robust pressure containment up to 16 bar in demanding hydronic circulation loops.
- Corrosion-resistant Composite impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 773 L/Min |
| Max Head | 19.3 m |
| Power | 3 kW / 415v |
| Rated Current | 5.80 Amps |
| Suitable For | Heating & Cooling Systems |
| Body Material | EN-GJL-250 Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 65 mm |
| Outlet Size | 65 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What electrical capacity, operating voltage configuration, and current draw are engineered?
Supplied for variable speed facilities, Grundfos TPE3 65-280 features a 3 kW motor operating across a three-phase 415 V connection at 5.8 Amps.
For hot and chilled hydronic media, what temperature spectrum is permitted under safe working pressure?
Circulating media temperatures between -25°C to 120°C are sustained by TPE3 65-280 with a maximum operating pressure of 16 bar.
Controlling differential pressure across secondary branches, what peak head is maintained under load?
Differential pressure optimization allows TPE3-65-280 to maintain a peak dynamic head of approximately 19.3 m.
Regulating secondary loop displacement, what maximum liquid circulation rate does this unit achieve?
Smooth volumetric displacement engineered into TPE3 65 280 reaches a peak circulation rate of approximately 773 L/Min.
To resist hydrodynamic wear, what alloy selection characterizes the casing and impeller?
The mechanical build of TPE3/65/280 combines an EN-GJL-250 cast iron outer body with an engineered composite impeller (PES-GF30).
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us