Grundfos TPE3 80-310 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Composite Impeller
SKU: 93338836

Grundfos TPE3 80-310 Cast Iron Variable Speed Three Phase Inline Centrifugal Pump with Composite Impeller

$13,521.26 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
1407 L/Min
Max Head
20.17 m
Power
5.5 kW / 415v
Ideal Use
Heating & Cooling Systems

Product Overview

The TPE3 80-310 in-line centrifugal pump is specified for clean water circulation across commercial heating and cooling installations, district energy plants, and industrial utility headers. Operating with a 5.5 kW electric drive, the unit features inline DN 80 pipe connections that mount straight into active fluid transfer lines without requiring offset piping manifolds.

Hydraulic performance testing confirms a rated output volume of 1407 L/Min with an operational head rating of 20.17 m. The EN-GJL-250 cast iron volute casing handles system line pressures up to 16 bar. Internal fluid movement is driven by a durable Composite impeller fitted with a BQQE mechanical seal. Product net weight equals 74.6 kg.

The electric drive motor operates on a 3 x 380-500 V Three-phase power source drawing 10.3 Amps nominal operating current at 5.5 kW drive output. The pump processes clean, non-aggressive fluids across liquid temperatures between -25°C to 120°C under maximum working pressures up to 16 bar. Flanged connections feature matching DN 80 inlet and outlet porting.

Built with an IP55 dust and moisture resistant motor enclosure, the unit features Class F thermal insulation for reliable continuous duty. An integrated variable frequency drive (VFD) and PI controller adjust motor speed dynamically to match real-time flow demand. Servicing is simplified by the top-pull-out architecture, allowing removal of the motor head and rotating assembly without disturbing main line pipe joints.

Features

  • High-efficiency motor design delivers optimized hydraulic throughput with minimal electrical power consumption across variable duty cycles.
  • EN-GJL-250 cast iron volute housing provides robust pressure containment up to 16 bar in demanding hydronic circulation loops.
  • Corrosion-resistant Composite impeller rotor is precision-balanced to minimize operational vibration and extend bearing lifecycle.
  • Standardized DN 80 flanged connections comply with EN 1092-2 for seamless drop-in integration into commercial pipe headers.
  • Maintenance-free BQQE mechanical shaft seal prevents fluid leakage and maintains seal integrity under elevated working pressures.
  • IP55 motor enclosure protection guards internal electrical components against ambient dust accumulation and water splash ingress.
  • Class F thermal motor insulation permits continuous operation under elevated fluid temperatures ranging from -25°C to 120°C.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow1407 L/Min
Max Head20.17 m
Power5.5 kW / 415v
Rated Current10.3 Amps
Suitable ForHeating & Cooling Systems
Body MaterialEN-GJL-250 Cast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size80 mm
Outlet Size80 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download

Hydronic risers in multi-story hotel complexes select The Grundfos TPE3 80-310 to maintain consistent pressure across vertical headers. Dynamic differential control modulates head pressure to deliver design flow to top-floor heating and cooling coils during peak occupancy.

  • Hydronic Risers
  • Hotel Complexes
  • Multi-Story HVAC
  • Boiler Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Through electronic inverter modulation, how much volumetric flow can this close coupled pump deliver?

With real-time sensor integration, Grundfos TPE3 80-310 maintains an operational volumetric delivery of approximately 1407 L/Min.

In terms of corrosion resistance, what materials are selected for the pump body and core?

The close coupled casing design of TPE3 80-310 combines EN-GJL-250 cast iron with an engineered composite impeller (PES-GF30).

What electrical input parameters, operating voltage, and running current are listed for this unit?

Designed for automated speed modulation, TPE3-80-310 features a 5.5 kW drive running on a three-phase 415 V line drawing 10.3 Amps.

Within hydronic system headers, what operating temperature limits and line pressures are permitted?

The casing and mechanical seal of TPE3 80 310 sustain process media across -25°C to 120°C with pressure limits reaching 16 bar.

Modulating motor power to eliminate excess line pressure, what peak dynamic head is achieved?

Across variable volume heating loops, TPE3/80/310 sustains an operational dynamic head of approximately 20.17 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us