Sized with a 50 mm nominal bore, the Grundfos UPS 50-60/2 F 415V circulator pump addresses moderate-flow secondary heating circuits and commercial chilled water systems. It installs into central plant distribution headers where low head loss and steady circulation are required.
Constructed with an EN-GJL-250 cast iron pump housing measuring 280 mm port-to-port, the unit incorporates an EN 1.4301 stainless steel impeller and aluminium stator body. It is rated for 10 bar working pressure and liquid temperatures from -10°C to 120°C, with a net mass of 20.6 kg.
The 3-phase 400-415 V 50 Hz motor has a maximum power input (P1) of 360 W with a peak electrical power input (P1) of 360 W and draws 0.74 A on speed 3, stepping down to 230 W on lower settings. Flow capacity reaches 15.5 m³/h (258 L/Min) with a maximum head of 4.8 m across DN 50 DIN flanged terminations.
The canned rotor configuration utilizes ceramic radial bearings and a carbon thrust bearing bathed in the pumped fluid, removing external seal maintenance. The terminal box provides IPX4D ingress protection and links internal thermal protection switches to safety disconnects.
FEATURES
- DN 50 flanged connection provides 258 L/Min maximum flow capacity for secondary headers
- Three manual operational speeds provide flexibility during hydronic balancing
- Three-phase 400-415 V motor creates balanced load on commercial power supplies
- Cast iron EN-GJL-250 housing rated for 10 bar maximum operational pressure
- Stainless steel AISI 304 impeller provides chemical durability in treated water
- Canned rotor motor design operates without gland packing or mechanical seals
- Standard 280 mm port-to-port dimension conforms to commercial DIN flange spacing
SPECIFICATIONS
| Max Flow | 258 L/Min |
| Max Head | 6 m |
| Power | 0.2 kW / 415v |
| Rated Current | 0.74 Amps |
| Suitable For | Secondary Heating and Cooling Circuits |
| Body Material | Cast Iron |
| Liquid Temperature | '-10°C to 120°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which system working pressure in bar and fluid temperature can this heavy circulator tolerate?
Commercial heating circulation thresholds establish that the UPS 50-60/2 F manages system pressures up to 10 bar across temperatures from -10°C to 120°C.
What peak dynamic head can this multi speed circulator sustain across distribution loops?
Delivering steady circulating pressure in heavy HVAC loops, the Grundfos UPS 50-60/2 F reaches a maximum dynamic head of approximately 6 m.
What peak delivery flow volume and connection flange diameter govern this heavy circulator?
Moving heating water through wide bore pipework via DN 50 flanged connections, the UPS-50-60/2-F delivers a maximum delivery flow volume of approximately 258 L/Min.
How does the robust cast iron metallurgy defend this commercial pump against system debris?
Hydronic longevity on the Grundfos UPS 50 60/2 F is reinforced by a robust Cast Iron housing with stainless steel impeller paired with precision-machined internal surfaces.
What supply voltage, electrical phase rating, and motor kilowatt consumption power this pump?
Driven by a three-speed motor stepping up to 0.2 kW (200 W), the UPS_50_60/2_F runs on 415 V drawing a rated current of 0.74 Amps.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us