Product Overview
Commercial drainage and site dewatering tasks demand a robust submersible solution with high starting torque and superior hydraulic efficiency. This Zenit model is ideal for clearing slightly dirty liquids from commercial sumps, excavation areas, and large-scale seepage collection pits. Its three-phase configuration is specifically tailored for professional environments where continuous duty and electrical load balance are critical operational factors.
Performance specifications for this unit include a maximum flow rate of up to 540 L/Min and a maximum head of approximately 12.5 m. The 0.9 kW motor is optimized for 415v three-phase power, providing the high efficiency and stable torque behavior required for demanding drainage duty. This technical profile ensures consistent liquid transfer across the operating range, even during periods of heavy inflow.
An open channel impeller is at the core of the pump's hydraulic performance, enabling it to process slightly dirty water containing small suspended solids. This configuration ensures smooth fluid movement while minimizing the risk of internal blockages during site duty. The submerged installation assists motor cooling during continuous operation, allowing the pump to maintain efficiency during intensive site dewatering tasks.
The pump is constructed with a heavy cast iron EN-GJL 250 body and an AISI 431 stainless steel shaft for maximum durability. Leakage protection is managed by a mechanical seal in silicon carbide with an auxiliary lip seal for enhanced safety. Rated for liquid temperatures up to 40°C, the three-phase unit features a 50 mm vertical outlet for simplified site integration.
FEATURES
- Three-phase 415v motor configuration provides superior torque and load balancing for sites.
- Cast iron EN-GJL 250 housing offers high structural support in submersible service.
- Mechanical seal in silicon carbide with auxiliary lip seal for enhanced protection.
- Open channel impeller designed to process slightly dirty commercial wastewater.
- 0.9 kW motor optimized for continuous duty in site dewatering and drainage pits.
- Vertical G 2" discharge port facilitates quick connection to professional piping networks.
- AISI 431 stainless steel shaft ensures long-term rotation precision and wear resistance.
- Internal motor protection sensors safeguard the three-phase motor against overloads.
SPECIFICATIONS
| Max Flow | 540 L/Min |
| Max Head | 12.5 m |
| Power | 0.88 kW / 415v |
| Rated Current | 2.3 Amps |
| Suitable For | Commercial Drainage or Site Dewatering |
| Body Material | Cast iron EN-GJL 250 |
| Liquid Temperature | Maximum 40°C |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which supply configuration is used by the motor?
Before connection, match DRE100_2_G50HTSIC_A0 to 415 V three-phase and verify that the site wiring supports this motor's specified electrical configuration.
Which impeller design is used for drainage?
The open-channel impeller on DRE100 2 G50HTSIC A0 is designed for slightly dirty water with small suspended solids during drainage.
What types of collected water can this pump transfer?
Commercial sumps and excavation areas are suitable for DRE100-2-G50HTSIC-A0, which moves slightly dirty water during professional site drainage from site collection pits.
Which seal design is used for submerged service?
The two silicon carbide mechanical seals (2SiC) on DRE100/2/G50HTSIC/A0 work alongside Class F insulation and IP68 protection to protect the motor during submerged operation.
What are the maximum flow and head ratings?
Maximum flow is 540 L/Min and maximum head is 12.5 m for DRE1002G50HTSICA0, driven by a 0.9 kW motor for site drainage.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us