Product Overview
Managing unstrained civil wastewater containing fibres or filaments requires specialized equipment capable of cutting solids before transfer. This electric unit serves domestic and professional needs effectively, offering suitability for installation in IECEx Zone 2 hazardous areas requiring certified equipment. Its IECEx certification (Ex nA nC IIC T3 Gc) ensures compliance with international safety standards for environments where flammable vapours may accumulate.
This model delivers a maximum head of up to 17 m and a flow rate of up to 240 L/Min, with the hydraulic system driven by a 0.74 kW electric motor. Operating on a standard single-phase 240v supply, it provides sufficient discharge pressure for residential elevations and civil wastewater disposal. The motor includes thermal protection, a starter box, starting capacitor and running capacitor to ensure reliable operation.
At its hydraulic core, a rotating chromium steel cutter works against a specialized cutting disk designed to cut fibrous materials and organic solids before they enter the hydraulic passage. The grinder system works in tandem with the open channel impeller to maintain efficient wastewater transfer. This design helps reduce the risk of blockages, ensuring that processed solids are transferred efficiently through the hydraulic flow path during standard duty cycles.
The structural assembly is built from heavy-duty EN-GJL 250 cast iron with an EN-GJS 600 foot base for high mechanical stability in wet installations. Motor protection is provided by a dual system of two silicon carbide (2SiC) mechanical seals, while the AISI 431 stainless steel shaft ensures long-term rotating alignment. A thick 120 µm bi-epoxy coating provides a protective shield over all internal and external cast iron surfaces against corrosion and chemical attack.
FEATURES
- IECEx Zone 2 certification (Ex nA nC IIC T3 Gc) ensures safe operation in hazardous environments requiring compliant equipment.
- High-strength grinder system with chromium steel cutters macerates organic solids and fibrous materials to reduce blockages.
- Professional dual mechanical seal arrangement featuring silicon carbide (2SiC) provides protection for the internal motor housing.
- Robust cast iron EN-GJL 250 construction and EN-GJS 600 base offer structural integrity for submerged service.
- Precision-engineered AISI 431 stainless steel shaft ensures high torsional strength and alignment of rotating elements.
- Motor protection includes thermal protection, starter box, starting capacitor and running capacitor for single-phase duty.
- Thick 120 µm bi-epoxy coating protects internal and external cast iron surfaces from corrosion and chemical attack.
- Threaded G 1"1/2 discharge connection facilitates standardized integration with wastewater coupling systems and piping.
SPECIFICATIONS
| Max Flow | 240 L/Min |
| Max Head | 17 m |
| Power | 0.75 kW / 240v |
| Rated Current | 5.5 Amps |
| Suitable For | Sewage Handling |
| Body Material | Cast iron - EN-GJL 250 |
| Liquid Temperature | Maximum 40°C |
| Outlet Size | 40 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which maximum flow and head values apply to this pump?
GRBLUEP100_2_G40HMEX has maximum flow of 240 L/Min and amaximum headrating of 17 m for hydraulic selection.
How is the pump body protected against wear?
The casing is Cast Iron EN-GJL 250, and GRBLUEP100 2 G40HMEX pairs it with an AISI 431 stainless steel shaft and mechanical seals.
Which motor supply and protection features does it use?
A 0.74 kW motor uses 240 V single-phase supply in GRBLUEP100-2-G40HMEX, with IECEx Zone 2 certification and motor thermal protection for submerged service.
What impeller or cutting arrangement manages solid waste?
A chromium steel cutter and cutting disk in GRBLUEP100/2/G40HMEX process fibres and organic solids before the open-channel impeller transfers wastewater.
Where is this pump intended to transfer wastewater?
For civil wastewater containing fibres, filaments and organic solids, GRBLUEP1002G40HMEX transfers wastewater from collection sumps and drainage systems across intended service settings.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us