Aussie Pumps GMP G2TMK-A2.2KW3PS2 Cast Iron Three Phase Series 2 High-Head Transfer Pump with Open Impeller
SKU: G2TMK-A2.2KW3PS2

Aussie Pumps GMP G2TMK-A2.2KW3PS2 Cast Iron Three Phase Series 2 High-Head Transfer Pump with Open Impeller

$3,415.50 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Aussie Pumps
3 Years
Peace of Mind
Max Flow
400 L/Min
Max Head
34 m
Power
2.2 kW / 415v
Ideal Use
Tank Water Supply

Product Overview

Agricultural packing sheds, dairy washdown racks, and industrial booster lines deploy the Aussie GMP G2TMK-A Series 2 pump on three-phase mains power. Dedicated motor mounting feet provide capable stability and reduce pipe strain on fixed manifolds.

Hydraulic delivery reaches an open-flow capacity of 375 L/min at zero static head and establishes a 33.5 m (48 PSI) shut-off head at zero flow. The heavy cast iron casing encloses an open-style impeller that clears suspended particulate and wash-grit up to 5 mm cleanly.

Dedicated 415 V plant drive is powered by a 2.2 kW three-phase TEFC two-pole motor rated to IP55 washdown protection, supplied unwired for hardwired isolator connection. Centrifugal self-priming suction draws fluid from 6 m vertical depths without a foot valve.

A replaceable suction port and 316 stainless motor shaft protect the volute from hydraulic wear at liquid temperatures up to 70°C intermittently. Standard 2-inch female BSP threaded ports streamline ongoing maintenance. Backed by an Aussie Pumps 3-year GMP warranty.

Features
  • Cast motor base feet in Series 2 design enhance mounting stability and lower vibration.
  • Industrial 2.2 kW three-phase 415 V TEFC two-pole electric motor with IP55 washdown rating.
  • High discharge pressure generating up to 33.5 m maximum shut-off head (48 PSI).
  • Delivers fluid movement up to 375 L/min open discharge at zero static head.
  • Vertical self-priming suction lift reaches 6 m without requiring an external foot valve.
  • Close-grained cast iron body includes a 316 stainless steel drive shaft and replaceable suction port.
  • Backed by an Aussie Pumps 3-year GMP pump warranty.
SPECIFICATIONS
Max Flow400 L/Min
Max Head34 m
Power2.2 kW / 415v
Suitable ForTank Water Supply
Body MaterialCast Iron
Inlet Size50 mm
Outlet Size50 mm
Warranty3 Years
Documents
Product Brochure Download
Specification Data Sheet Download
Spare Parts Manual Download
Operating Manual Download
Overhaul Instructions Download

At production plant nurseries and broadacre hydroponic complexes, the Aussie Pumps GMP High Pressure Transfer G2TMK-A supplies pressurized water to overhead misting nozzles and micro-sprinklers. Three-phase power delivers smooth motor operation across long irrigation cycles.

  • Nursery Misting System Supply
  • Hydroponic Main Line Boosting
  • Overhead Sprinkler Pressure
  • Clean Irrigation Water Transfer

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Spare Parts Manual
Download
Operating Manual
Download
Overhaul Instructions
Download
How is site electricity connected to run this electric pump package?

Installation of the Aussie Pumps GMP High Pressure Transfer G2TMK-A (G2TMK-A2.2KW3PS2) connects to a standard three-phase 415 V supply to run the 2.2 kW electric motor, protected by an IP55 terminal enclosure.

What peak discharge throughput and head elevation are developed by the impeller?

Operating across its curve, the G2TMK-A2.2KW3PS2 achieves a maximum flow rate of approximately 400 L/min and reaches a maximum elevation head of approximately 34 m.

Why are closed impellers used instead of open vanes in this unit?

Closed impellers on the G-2TMK-A-2.2KW-3PS-2 maximize hydraulic efficiency to develop 34 m of elevation head for long overland pipelines and elevated storage tanks.

What mechanical seal combination delivers longevity when pumping dirty water?

A silicon carbide mechanical seal on the G2TMK A2.2KW3PS2 with an alumina counterface and nitrile elastomers safeguards the motor shaft against gritty liquid ingress.

Does this self priming pump need an intake foot valve when drawing from trenches?

No foot valve is needed on the G2TMK-A (G2TMK-A2.2KW3PS2) because internal recirculation channels draw fluid vertically up to 6 m once the pump casing is filled.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed