Roll over image to zoom
SKU: G2TMK-A/B2.2KW
Aussie Pumps GMP G2TMK-A/B2.2KW High-Head Nial Bronze Three Phase Marine Transfer Pump with Open Impeller
Australia-Wide
(08) 9240 2992
Official Aussie Pumps
Peace of Mind
Product Overview
Engine-room 415 V boards feed pressure-washing and deck-service loops through this three-phase high-head bronze pump, holding a 34-metre shut-off head in reserve for nozzles and eductors. Balanced three-phase draw suits generator sets. Generator-fed 415 V pressure loops use G2TMK-A/B2.2KW for balanced three-phase draw.
Delivery peaks at 400 L/min open discharge, shutting off at 34 m head (48 PSI). Heavy-duty cast nickel-aluminium bronze to Mil-Spec equivalent standard forms the casing and large open impeller for 8 mm solids, with carbon/alumina sealing, nitrile rubber and a 316 stainless casing.
Generator sets feed the balanced 2.2 kW three-phase 415 V IP54 motor through panel connection, lead-free from the box. Unaided 6 m priming through twin 2-inch ports suits skid mounting, and grit wear absorbs into the bolt-off suction cover.
This pump is intended for marine deck washdown, bilge pump-out, salvage pumping and marine air-conditioning circulation. Those duties cover regular deck cleaning, bilge clearing and onboard water movement, making it a practical fit for workboats, tenders, fishing vessels and marina service installations. Where Viton seals are specified, AdBlue and chemical transfer are also within the listed application range.
Features
- Generator-friendly balanced 2.2 kW 415 V IP54 three-phase drive runs cleanly from site generator sets.
- Maximum flow of 400 L/min, shutting off at 34 m (48 PSI) holds pressure for nozzles and eductors.
- Mil-Spec equivalent high-head bronze casing and impeller are engineered for sustained elevation duty.
- Solids handling of 8 mm for screened supply water protects close-tolerance nozzles downstream.
- Skid-ready unaided self-priming of 6 m with a bolt-off cover suits mobile pressure units.
- AdBlue qualification follows once fitted Viton elastomers replace the standard seals entirely.
- Covered by the 3 year Aussie GMP warranty from installation.
SPECIFICATIONS
| Max Flow | 400 L/Min |
| Max Head | 34 m |
| Power | 2.2 kW / 415v |
| Suitable For | Marine Deck Washdown |
| Body Material | Nickel-Aluminium Bronze |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 3 Years |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
How is the electric motor configured regarding incoming voltage and phase supply within outdoor switchboard setups?
Electric power drives the Aussie Pumps Bronze Electric High Pressure G2TMK-A/B (G2TMK-A-B2.2KW) via a close-coupled unit rated at 2.2 kW 415V 3-Phase, wired into fixed switchboard connections.
How does marine bronze metallurgy protect internal waterways against saltwater degradation without suffering pitting corrosion?
Cast nickel-aluminium bronze metallurgy on the G2TMK A B2.2KW resists aggressive saltwater corrosion across marine decks, bilges, and oyster leases.
Does the suction line require a foot valve to draft liquid from below ground across routine site transfer duties?
Automatic priming action on the G2TMK-A/B2.2KW drafts liquid from vertical depths down to 6 m without needing a foot valve.
How does the open vane impeller pass suspended particles without jamming internal channels when pumping slurry runoff?
Internal waterways and the nickel-aluminium bronze impeller on the G2TMK-A/B2.2KW accommodate suspended solids and spherical matter up to 8 mm across without restricting fluid throughput.
What maximum fluid displacement rate and shut off ceiling are developed across long transfer runs?
At peak operational capacity, the wet end of the G2TMK-A/B (G2TMK-A/B2.2KW) produces up to approximately 400 L/min in open flow and reaches a maximum elevation head of approximately 34 m.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us