Roll over image to zoom
Aussie Pumps GMP G2TMK-A/B2.2KW1P High-Head Nial Bronze Single Phase Marine Transfer Pump with Open Impeller
Australia-Wide
(08) 9240 2992
Official Aussie Pumps
Peace of Mind
Product Overview
Masthead washdown and high-level deck services on single-phase shore power get their pressure from this high-head 2-inch bronze pump, throwing water 34 metres skyward off a standard 240 V outlet. Height, not volume, is the mission. Single-phase high-head buyers list G2TMK-A/B2.2KW1P for 240 V pressure service.
Open flow reaches 400 L/min with shut-off at a 34 m (48 PSI) head. The Mil-Spec equivalent cast nickel-aluminium bronze wet end carries a large open impeller passing 8 mm solids, sealed by carbon against alumina with nitrile rubber in a 316 stainless casing.
Close-coupled to the pump, the 2.2 kW single-phase 240 V IP54 motor needs only direct wiring with no lead or plug, keeping single-phase high-head installations simple. The 2-inch ports self-prime from 6 m, and the wear point stays renewable through the replaceable suction cover.
Marine deck washdown, bilge pump-out, salvage pumping and marine air-conditioning duties place this unit where working boats need one pump to cover routine water management as well as emergency clearing. It suits washdown plumbing, bilge service and salvage work across commercial and recreational vessels. Where Viton seals are specified, AdBlue and chemical transfer are also within the listed application range.
Features
- Simplified single-phase wiring with the 2.2 kW 240 V IP54 motor needs no lead or plug, just direct connection.
- Open flow of 400 L/min, shutting off at 34 m (48 PSI) throws washdown water to real height.
- Pressure-first engineering shapes the high-head Mil-Spec equivalent bronze wet end with open impeller.
- Screened-water solids passage of 8 mm suits nozzle and eductor supply from filtered sources.
- Renewable wear point with 6 m self-priming lift keeps high-head service economical to maintain.
- Chemical possibility follows the Viton seal option for operators with dual duties.
- Covered by the 3 year Aussie GMP warranty from installation.
SPECIFICATIONS
| Max Flow | 400 L/Min |
| Max Head | 34 m |
| Power | 2.2 kW / 240v |
| Suitable For | Marine Air Conditioning |
| Body Material | Nickel-Aluminium Bronze |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 3 Years |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Does the suction line require a foot valve to draft liquid from below ground when drafting from deep sumps?
Built-in priming passages on the Aussie Pumps Bronze Electric High Pressure G2TMK-A/B (G2TMK-A-B2.2KW1P) draw fluid vertically from depths up to 6 m without requiring an external foot valve once the casing is filled.
What maximum fluid displacement rate and shut off ceiling are developed under full operating speed?
Across open pipeline runs, the G2TMK A B2.2KW1P pushes fluid at a maximum throughput of approximately 400 L/min while attaining a shut-off head ceiling of approximately 34 m.
How does the open vane impeller pass suspended particles without jamming internal channels during dirty liquid transfer?
Internal casing clearances on the G2TMK-A/B2.2KW1P allow the open nickel-aluminium bronze impeller to digest spherical matter up to 8 mm without binding.
What advantages does cast bronze construction provide for oyster leases and fish farming in demanding marine applications?
Seawater corrosion resistance on the G2TMK-A/B2.2KW1P is achieved through cast nickel-aluminium bronze construction across the volute and impeller.
How is the electric motor configured regarding incoming voltage and phase supply during fixed installation wiring?
Incoming electrical supply operates the G2TMK-A/B (G2TMK-A/B2.2KW1P) through an electric motor delivering 2.2 kW 240V 1-Phase.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us










