Product Overview
Long classified-area rising mains yield to this 7.5 kW high-head flameproof pump, holding a 44-metre shut-off head in reserve while passing up to 850 litres a minute. Distance and elevation stop dictating station design. Long classified rising mains yield to G3TMK-A-ATEX7.5K with 44 metres of certified head.
Maximum flow touches 850 L/min with shut-off at 44 m (63 PSI) on fresh-water viscosity liquids. Heavy-duty cast construction with a replaceable suction cover runs an open-style impeller clearing 13 mm solids, sealed Viton/carbon/alumina as standard.
Freeing station design from distance constraints, the 7.5 kW three-phase 415 V flameproof motor holds ATEX certification with IP55 protection, base-mounted on steel for long rising mains. Twin 3-inch ports prime unaided from 6 m.
Diesel and fuel-oil transfer in hazardous environments is the central application, extending to machinery, marine diesel, earth-moving equipment, mining plant and generator refuelling. Waste-oil collection and heating-oil transfer are also listed, covering fixed fuel points as well as mobile service and maintenance work.
Features
- Constraint-freeing 7.5 kW 415 V three-phase ATEX motor with IP55 protection mounts on a steel base plate for rising mains.
- Open discharge of 850 L/min, shutting off at 44 m (63 PSI) frees station design from distance limits.
- Long-main twin 3-inch ports with 13 mm solids capability pass raw main-line water.
- Classified high-head service relies on Viton, carbon and alumina seals fitted as standard.
- Unaided 6 m self-priming with a renewable suction cover suits unmanned stations.
- Flameproof configuration is selected for diesel-transfer work in the listed hazardous-area applications.
- Covered by the 3 year Aussie GMP warranty from installation.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
From what depth below ground can internal fluid pathways draft water automatically without requiring an external foot valve?
Built-in priming passages on the Aussie Pumps ATEX Electric High Pressure G3TMK-A/ATEX (G3TMK-A-ATEX7.5K) draw fluid vertically from depths up to 6 m without requiring an external foot valve once the casing is filled.
What maximum water displacement and vertical head does this package develop across long transfer runs?
Across open pipeline runs, the G3TMK-A-ATEX7.5K pushes fluid at a maximum throughput of approximately 850 L/min while attaining a shut-off head ceiling of approximately 44 m.
What diameter solid matter can flow through the internal waterways without stalling the wet end across high volume transfer lines?
Internal waterways and the cast iron impeller on the G3TMK-A-ATEX7.5K accommodate suspended solids and spherical matter up to 13 mm across without restricting fluid throughput.
How does the certified flameproof terminal enclosure protect hazardous refueling areas around flammable chemical storage bunds?
Certified explosion-proof motor construction equips the G3TMK-A-ATEX7.5K to transfer fuels, solvents, and volatile liquids safely within classified zones.
What terminal enclosure protection seals the electric motor against moisture without requiring phase converters?
Incoming electrical supply operates the G3TMK-A/ATEX (G3TMK-A-ATEX7.5K) through an electric motor delivering 7.5 kW 415V 3-Phase.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations