Aussie Pumps GMP G3TMK-A/X 7.5 3P Stainless Steel Three Phase Chemical Transfer Pump with High-Head Impeller
SKU: G3TMK-A/X 7.5 3P

Aussie Pumps GMP G3TMK-A/X 7.5 3P Stainless Steel Three Phase Chemical Transfer Pump with High-Head Impeller

$18,108.20 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Aussie Pumps
3 Years
Peace of Mind
Max Flow
850 L/Min
Max Head
44 m
Power
7.5 kW / 415v
Ideal Use
Chemical Supply

Product Overview

Solids-laden wastewater processing, acidic slurry pits, and factory washdown manifolds utilize the Aussie GMP G3TMK-A/X motor-driven unit in cast large stainless steel. Its structural steel foundation absorbs hydraulic torque during continuous plant cycling.

High-head acid throughput reaches an impressive 850 L/min open discharge at zero elevation, accompanied by a 44 m (63 PSI) shut-off head at zero flow. A cast 316 stainless steel volute encloses a high-head open impeller capable of passing solids up to 13 mm cleanly.

High-torque chemical power originates from a 7.5 kW three-phase 415 V TEFC motor with IP55 ingress protection, supplied unwired without a lead or plug for hardwired control panel setups. Rapid self-priming lifts acidic wastewater from 6 m depths without a foot valve.

Acidic slurry wear protection includes a sacrificial 316 stainless suction cover and 316 SS-cased mechanical seal handling fluid temperatures up to 70°C intermittently. Full 3-inch BSP ports allow rapid piping hookups. Backed by Aussie Pumps 3-year factory warranty.

Features
  • Hydraulic wet end handles suspended solids and abrasive particulate up to 13 mm.
  • Generates fluid delivery up to 850 L/min open discharge at zero static head.
  • Cast 316 stainless steel metallurgy delivers complete defense against solids-laden chemicals.
  • Powerful 7.5 kW three-phase 415 V TEFC motor configured for continuous factory service with IP55 rating.
  • Replaceable 316 stainless steel suction cover protects the pump casing from erosive slurry wear.
  • Backed by an Aussie Pumps 3-year GMP pump warranty.
SPECIFICATIONS
Max Flow850 L/Min
Max Head44 m
Power7.5 kW / 415v
Suitable ForChemical Supply
Body Material316 Stainless Steel
Inlet Size80 mm
Outlet Size80 mm
Warranty3 Years
Documents
Product Brochure Download
Specification Data Sheet Download
Spare Parts Manual Download
Operating Manual Download
Overhaul Instructions Download

In petrochemical processing plants and fuel blending zones, the Aussie Pumps GMP 316 Stainless Steel ATEX High Pressure G3TMK-A/X delivers pressurized wash streams for sanitizing reactor vessels in explosion-hazard atmospheres. Certified flameproof architecture provides complete facility protection.

  • Hazardous Zone Vessel Washdown
  • Petrochemical Reactor Washing
  • Flammable Chemical High-Head Transfer
  • Explosion-Proof Plant Washdown

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Spare Parts Manual
Download
Operating Manual
Download
Overhaul Instructions
Download
How does this unit deliver high pressure washdown in explosion hazard atmospheres?

Multi-stage 316 stainless steel impellers on the Aussie Pumps GMP 316 Stainless Steel ATEX High Pressure G3TMK-A/X (G3TMK-A/X 7.5 3P) produce 44 m of head to feed pressurized wash streams for sanitizing reactor vessels in vapor zones.

How is incoming power configured to drive the electric motor package?

Propulsion for the G3TMK-A/X 7.5 3P is delivered by a three-phase electric motor generating 7.5 kW on 415 V line supply, protected by an IP55 terminal enclosure.

How does the shaft seal design stop dirty fluid from reaching the motor bearings?

A carbon ceramic mechanical seal on the G3TMK-A-X-7.5-3P with an alumina counterface and Viton elastomers stops chemical fluids from reaching the motor shaft.

What maximum diameter spherical matter can pass safely through the volute?

Internal water channels on the G3TMK A X 7.5 3P accommodate suspended solid particles and chemical precipitates up to 13 mm in diameter without binding.

What open discharge flow and total dynamic elevation head are rated for this pump?

Discharge throughput for the G3TMK-A/X (G3TMK-A/X 7.5 3P) reaches up to approximately 850 L/min at peak volume while developing a maximum elevation head of approximately 44 m.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed