Refuelling crews working inside bunded compounds and underground tanks move diesel safely on standard single-phase power with this flameproof 1½-inch transfer pump, certified for hazardous atmospheres where ordinary motors are barred. Compliance starts at the motor, not as an accessory. Single-phase hazardous-area refuelling is ordered as GB1.5KQ-A/ATEX1P for 240 V supply.
Open-discharge flow reaches 290 L/min, shutting off at 16 m head (23 PSI), rated on fresh-water viscosity liquids. Heavy-duty cast construction with a replaceable suction cover houses a big open impeller passing 8.5 mm solids, sealed by Viton/carbon/alumina as standard.
Running from a standard 240 V outlet, the 0.75 kW single-phase flameproof motor carries full ATEX certification with IP55 protection for classified air. Light 1½-inch pipework keeps trolley and skid layouts portable, priming from 6 m depths with the wear isolated to a replaceable suction cover.
Diesel and fuel-oil transfer in hazardous environments is the central application, extending to machinery, marine diesel, earth-moving equipment, mining plant and generator refuelling. Waste-oil collection and heating-oil transfer are also listed, covering fixed fuel points as well as mobile service and maintenance work.
Features
- Standard-outlet flameproof drive with the 0.75 kW 240 V ATEX motor and IP55 protection suits classified air.
- Open flow of 290 L/min, shutting off at 16 m (23 PSI) is rated on fresh-water viscosity liquids for honest sizing.
- Portable 1½-inch porting with 8.5 mm solids through the big open impeller keeps trolley layouts light.
- Fuel-proof Viton, carbon and alumina sealing is fitted as standard, not as an optional extra.
- Depth-capable self-priming of 6 m with an isolated wear cover suits bunded compounds and underground tanks.
- Flameproof configuration is selected for diesel-transfer work in the listed hazardous-area applications.
- Covered by the 3 year Aussie GMP warranty from installation.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What open discharge throughput and maximum dynamic head are rated through connected piping?
Operating across its performance curve, the Aussie Pumps ATEX Electric Explosion-Proof B1.5KQ-A/ATEX (GB1.5KQ-A-ATEX1P) discharges a maximum flow rate of approximately 290 L/min and develops a maximum elevation head of approximately 16 m.
Can this semi trash pump pass slurry debris and spherical particles freely during routine excavation drainage?
Debris-laden wastewater containing solids up to 8.5 mm across passes freely through the open cast iron impeller fitted to the GB1.5KQ A ATEX1P.
What type of electrical supply is needed to run the drive motor on site during fixed installation wiring?
The close-coupled electric drive on the GB1.5KQ-A/ATEX1P operates with a motor rated at 0.75 kW 240V 1-Phase, providing steady operating torque across site duties.
How do the internal recirculation channels achieve rapid priming from deep excavations without requiring an external foot valve?
Vertical suction capability on the GB1.5KQ-A/ATEX1P reaches up to 6 m, evacuating intake line air swiftly without requiring a flooded suction inlet.
What explosion safety certifications equip this pump for volatile chemical environments across petrochemical transfer areas?
Certified explosion-proof motor construction equips the B1.5KQ-A/ATEX (GB1.5KQ-A/ATEX1P) to transfer fuels, solvents, and volatile liquids safely within classified zones.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us