Roll over image to zoom
SKU: GB2KQ-A ATEX3P
Aussie Pumps GMP GB2KQ-A ATEX3P Flameproof Three Phase 2" Ports Diesel Transfer Pump with Open Impeller
Australia-Wide
(08) 9240 2992
Official Aussie Pumps
Peace of Mind
Product Overview
Bulk fuel installers standardise on this three-phase 2-inch flameproof pump for depot-scale diesel movement, balancing 440 litres a minute across 415 V phases inside classified transfer bays. Continuous-rated flameproof construction suits around-the-clock bowser duty. Depot-scale classified transfer standardises on GB2KQ-A ATEX3P for 415 V bowser bays.
Hydraulics cover 440 L/min open flow to a 19 m (27 PSI) shut-off head on fresh-water viscosity liquids. The heavy-duty cast wet end with renewable suction cover runs a big open impeller for 16 mm solids, with standard Viton/carbon/alumina sealing.
Balanced across 415 V phases, the 1.5 kW ATEX flameproof motor in its IP55 frame suits continuous bowser duty inside classified transfer bays. Suction and discharge manifolds meet at twin 2-inch connections, self-priming from 6 m with the suction cover removable for wear renewal.
Diesel and fuel-oil transfer in hazardous environments is the central application, extending to machinery, marine diesel, earth-moving equipment, mining plant and generator refuelling. Waste-oil collection and heating-oil transfer are also listed, covering fixed fuel points as well as mobile service and maintenance work.
Features
- Continuous-duty 1.5 kW 415 V three-phase ATEX motor with IP55 protection suits around-the-clock bowser operation.
- Open flow of 440 L/min, shutting off at 19 m head (27 PSI) balances volume with classified compliance.
- Manifold-friendly twin 2-inch connections with 16 mm solids join fixed transfer pipework directly.
- Waste-oil-proof mechanical sealing in standard Viton, carbon and alumina handles diesel continuously.
- Removable wear cover with 6 m self-priming depth makes servicing a bay-side task.
- Flameproof configuration is selected for diesel-transfer work in the listed hazardous-area applications.
- Covered by the 3 year Aussie GMP warranty from installation.
SPECIFICATIONS
| Max Flow | 440 L/Min |
| Max Head | 19 m |
| Power | 1.5 kW / 415v |
| Suitable For | Diesel Fuel Oil Transfer In Hazardous Environments |
| Body Material | Cast Iron |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 3 Years |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What type of electrical supply is needed to run the drive motor on site to initiate shaft rotation?
Electric power drives the Aussie Pumps ATEX Electric Explosion-Proof B2KQ-A/ATEX (GB2KQ-A-ATEX3P) via a close-coupled unit rated at 1.5 kW 415V 3-Phase, wired into fixed switchboard connections.
How does certified flameproof motor construction eliminate spark ignition risks in vapor zones across petrochemical transfer areas?
Certified flameproof ATEX Ex-d motor construction on the GB2KQ A ATEX3P encloses electrical arcs, enabling safe operation in hazardous fuel and solvent vapor zones.
How do the internal recirculation channels achieve rapid priming from deep excavations across routine site transfer duties?
Automatic priming action on the GB2KQ-A ATEX3P drafts liquid from vertical depths down to 6 m without needing a foot valve.
What particle clearance does the open impeller allow when pumping dirty runoff across demanding site dewatering duties?
The open cast iron impeller on the GB2KQ-A ATEX3P allows spherical solids up to 16 mm in diameter to pass freely without choking internal water passages.
What open discharge throughput and maximum dynamic head are rated when discharging into storage tanks?
At peak operational capacity, the wet end of the B2KQ-A/ATEX (GB2KQ-A ATEX3P) produces up to approximately 440 L/min in open flow and reaches a maximum elevation head of approximately 19 m.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us