Aussie Pumps GMP GB2KQA/ST2.23PS2 Cast Iron Three Phase Series 2 Semi-Trash Pump with Open Impeller
SKU: GB2KQA/ST2.23PS2

Aussie Pumps GMP GB2KQA/ST2.23PS2 Cast Iron Three Phase Series 2 Semi-Trash Pump with Open Impeller

$2,919.40 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Aussie Pumps
3 Years
Peace of Mind
Max Flow
450 L/Min
Max Head
19 m
Power
2.2 kW / 415v
Ideal Use
Abattoir Waste

Product Overview

Manufacturing facilities, livestock yards, and mining sumps deploy the Aussie GMP B2KQ-A/ST Series 2 pump for continuous three-phase waste handling. Structural motor base feet provide capable stability against pipe thrust and hydraulic pulsation.

Discharge volume peaks at 440 L/min under open-flow conditions, while total shut-off head develops to 18 m (26 PSI) at zero flow. An open non-clog cast impeller transfers compressible solids, manure, and slurry up to 19 mm in diameter without choking the pump wet end.

Factory electric power is delivered by an enclosed 2.2 kW three-phase 415 V TEFC motor rated to IP55 washdown protection, supplied unwired for direct switchboard hardwiring. The internal wet end self-primes from vertical suction depths of 6 m without a foot valve.

High-density cast iron casing encloses a 316 stainless shaft, replaceable wear plate, and silicon carbide seal that handles fluid temperatures up to 70°C. Front clean-out doors streamline maintenance without pipe removal. Backed by a 3-year GMP warranty.

Features
  • Three-phase 415 V 2.2 kW TEFC electric drive rated to IP55 protection for heavy factory duty.
  • Processes abrasive spherical and compressible solids up to 19 mm without pump stalling.
  • Fluid output generates up to 440 L/min open flow alongside an 18 m shut-off head (26 PSI).
  • Series 2 motor-foot casting isolates mechanical vibration from connecting pipework.
  • Rapid internal self-priming draws liquid from vertical suction depths up to 6 m.
  • Front clean-out hatch allows swift chamber flushing without pipe disconnection.
  • Supplied with Aussie Pumps 3-year factory GMP pump warranty coverage.
SPECIFICATIONS
Max Flow450 L/Min
Max Head19 m
Power2.2 kW / 415v
Suitable ForAbattoir Waste
Body MaterialCast Iron
Inlet Size50 mm
Outlet Size50 mm
Warranty3 Years
Documents
Product Brochure Download
Specification Data Sheet Download
Spare Parts Manual Download
Operating Manual Download
Overhaul Instructions Download

Installed on piggeries and intensive livestock farms, the Aussie Pumps GMP Semi-Trash B2KQ-A/ST moves raw livestock slurry between holding tanks and secondary settlement ponds. Its three-phase motor runs steadily in damp agricultural shed environments.

  • Piggery Effluent Pumping
  • Livestock Lagoon Circulation
  • Organic Slurry Transfer
  • Farm Sump Dewatering

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Spare Parts Manual
Download
Operating Manual
Download
Overhaul Instructions
Download
What intake and discharge port connections are fitted to the housing?

Both suction and discharge ports on the Aussie Pumps GMP Semi-Trash B2KQ-A/ST (GB2KQA/ST2.23PS2) feature standard female BSP threads designed for direct coupling to site hoses and pipework.

Can this unit self prime from lower collection sumps without manual assistance?

Internal fluid pathways on the GB2KQA/ST2.23PS2 evacuate air automatically once the chamber is charged, pulling fluid vertically from depths down to 6 m.

What peak liquid delivery and shut off head are developed through site discharge lines?

Hydraulic output for the GB2KQA-ST2.23PS2 delivers a maximum volume of approximately 450 L/min and achieves a maximum elevation head of approximately 19 m across its operating curve.

What power requirements and motor enclosure rating apply to this electric drive package?

Shaft propulsion for the GB2KQA ST2.23PS2 is supplied by a three-phase electric motor rated at 2.2 kW on 415 V line voltage, housed in an IP55 terminal casing.

How does the casing construction resist abrasive slurry wear across site operations?

On the B2KQ-A/ST (GB2KQA/ST2.23PS2), close-grained cast iron metallurgy paired with a sacrificial stainless steel wear plate protects internal surfaces against grit abrasion.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed