Roll over image to zoom
SKU: GB3KQ-A ATEX240
Aussie Pumps GMP GB3KQ-A ATEX240 Flameproof Single Phase 3" Ports Diesel Transfer Pump with Open Impeller
Australia-Wide
(08) 9240 2992
Official Aussie Pumps
Peace of Mind
Product Overview
Rural fuel depots and earthmoving workshops on single-phase supply transfer diesel at 750 litres a minute through this flameproof 3-inch pump, emptying bulk tanks fast inside hazardous ratings. No three-phase line needed for serious flow. Rural high-volume transfer without three-phase power calls for GB3KQ-A ATEX240 on 240 V.
Open-discharge delivery tops 750 L/min with shut-off at 16 m (23 PSI) of head on fresh-water viscosity liquids. Heavy-duty cast construction with a replaceable suction cover houses a big open impeller passing 27 mm solids, sealed Viton/carbon/alumina as standard.
Serious 3-inch flow needs no three-phase line here: the 2.2 kW single-phase 240 V flameproof motor carries ATEX certification with IP55 protection for rural depots. Tank-to-tank layouts use the full 3-inch ports with 6 m self-priming suction, renewing wear through the replaceable cover.
This flameproof configuration is specified for hazardous-area diesel and fuel-oil movement, including machinery and marine refuelling, earth-moving fleets, mining plant and generators. Its listed duties also include waste-oil collection and heating-oil transfer, supporting fuel-service work wherever hazardous-area requirements apply.
Features
- Rural-depot 2.2 kW 240 V single-phase flameproof ATEX motor with IP55 sealing brings volume to single-phase sites.
- Open flow of 750 L/min, shutting off at 16 m (23 PSI) empties bulk tanks in fewer sessions.
- Tank-to-tank 3-inch porting with 27 mm solids clearance moves earthmover and farm fuel fast.
- Fuel-proofing from Viton, carbon and alumina seals is fitted as standard equipment.
- Renewable wear cover with 6 m self-priming lift keeps rural servicing simple and cheap.
- Flameproof configuration is selected for diesel-transfer work in the listed hazardous-area applications.
- Covered by the 3 year Aussie GMP warranty from installation.
SPECIFICATIONS
| Max Flow | 750 L/Min |
| Max Head | 16 m |
| Power | 2.2 kW / 240v |
| Suitable For | Marine Diesel |
| Body Material | Cast Iron |
| Inlet Size | 80 mm |
| Outlet Size | 80 mm |
| Warranty | 3 Years |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What particle clearance does the open impeller allow when pumping dirty runoff during routine excavation drainage?
The open cast iron impeller on the Aussie Pumps ATEX Electric Explosion-Proof B3KQ-A/ATEX (GB3KQ-A-ATEX240) allows spherical solids up to 27 mm in diameter to pass freely without choking internal water passages.
Can this unit pull liquid from storage sumps without flooded suction lines during everyday operations?
No foot valve is needed on the GB3KQ A ATEX240 with a self-priming lift of up to 6 m once the casing is filled.
How does certified flameproof motor construction eliminate spark ignition risks in vapor zones during solvent and fuel decanting?
Certified explosion-proof motor construction equips the GB3KQ-A ATEX240 to transfer fuels, solvents, and volatile liquids safely within classified zones.
How much fluid volume can the wet end displace every minute across open site lines?
Discharge performance for the GB3KQ-A ATEX240 yields an open flow volume of approximately 750 L/min and reaches a maximum shut-off elevation of approximately 16 m.
What type of electrical supply is needed to run the drive motor on site across local power connections?
Incoming electrical supply operates the B3KQ-A/ATEX (GB3KQ-A ATEX240) through an electric motor delivering 2.2 kW 240V 1-Phase.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us










