Aussie Pumps Mr T QPT305SLT/L100M Aluminium 10HP Twin Impeller Firefighting Pump with Yanmar L100M Diesel Engine
SKU: QPT305SLT/L100M

Aussie Pumps Mr T QPT305SLT/L100M Aluminium 10HP Twin Impeller Firefighting Pump with Yanmar L100M Diesel Engine

$10,542.40 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Aussie Pumps
5 Years
Peace of Mind
Max Flow
480 L/Min
Max Head
90 m
Power
Yanmar L100 Diesel Electric Start Engine
Ideal Use
Mining

Product Overview

Mineral processing plants and open pit mines commission the Aussie Mine Boss Mr T (QPT305SLT/L100M) high volume twin stage diesel pump for plant emergency washdown and perimeter fire defense around machinery workshops. Fully equipped with a battery isolation switch, emergency stop button, and stainless steel roll cage, it meets Australian mining safety guidelines. Dual impellers push heavy water volumes across elevated pipe runs without pressure loss.

Mine Boss structural stainless steel frame with center lifting bar, lockable battery isolation, E-stop & fire extinguisher encloses the equipment while isolating mechanical vibration and simplifying site movement. The structural mount provides balance during transport across field vehicles, trailers, and utility trays. Complete spare parts support and factory technical documentation are accessible through Aussie Pumps distribution networks across Australia.

High elevation delivery volume achieves a maximum delivery rate of 480 L/min and develops a maximum elevation head of 90 m. Internal hydraulic architecture features a marine grade aluminium casing, twin closed aluminium impellers mounted on a single drive shaft, and a carbon ceramic mechanical seal with nitrile elastomers. Total equipment mass measures 115 kg in dry operating trim.

Mechanical drive is provided by a Yanmar L100 10HP electric start diesel engine (includes sealed gel battery) producing 10 HP. Plumbing connections incorporate 3" BSP male inlet & 3" BSP male outlet, and the self-priming wet end achieves 7.6 m vertical suction lift. Rapid self-priming internal dynamics pick up fluid swiftly without requiring manual foot valves on suction lines.

Features

  • The 3-inch alloy body shrugs off corrosion across seasons of farm use.
  • A large internal liquid reservoir delivers fast self-priming from 7.6 m depth.
  • Twin closed aluminium impellers push discharge heads up to 90 m.
  • Straightforward 3-inch suction and discharge porting moves high volumes with low friction.
  • The serviceable suction valve holds prime in the casing between jobs.
  • Mine-spec safety package with stainless steel roll frame, lockable battery isolation switch and emergency stop button.
  • Aussie Pumps covers the pump end for 5 years with 2-year Yanmar engine warranty support.
SPECIFICATIONS
Max Flow480 L/Min
Max Head90 m
PowerYanmar L100 Diesel Electric Start Engine
Suitable ForMining
Body MaterialMarine Grade Aluminium
Inlet Size80 mm
Outlet Size3-way (2 x 25 mm, 1 x 40 mm)
Warranty5 Years
Documents
Specification Data Sheet Download
Spare Parts Manual Download
Operating Manual Download
Troubleshooting Guide Download
Overhaul Instructions Download

At open pit mining operations, the Aussie Pumps Mine Boss Mr T QPT305SLT powers high-pressure water lines for dust mitigation and site emergency fire defense. Mine-spec isolation hardware, stainless roll frame, and twin impellers satisfy demanding site compliance standards.

  • Open Pit Mining
  • Dust Mitigation Lines
  • Emergency Fire Defense
  • Mine Site Safety

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Data Sheet
Download
Spare Parts Manual
Download
Operating Manual
Download
Troubleshooting Guide
Download
Overhaul Instructions
Download
Which mine site compliance hardware and electrical isolation are installed?

Built to satisfy Australian resource site safety rules, the Aussie Pumps Mine Boss Mr T (QPT305SLT/L100M) incorporates a welded stainless steel frame, lockable battery isolation switch, and emergency stop control.

Which warranty terms cover the pump casing and drive engine?

Protection for the QPT305SLT/L100M includes a 5-year pump end warranty, 2-year Yanmar engine warranty, providing verified Australian warranty backing and technical support.

How is the drive engine configured and started on this unit?

Power for the QPT305SLT-L100M comes from a Yanmar L100 10HP electric start diesel engine, equipped with an electric key start ignition for straightforward field deployment.

Which suction and delivery port fittings are included?

Suction intake on the QPT305SLT L100M is provided via 80 mm BSP threading, with delivery directed through 3-way (2 x 25 mm, 1 x 40 mm) BSP fittings.

What peak flow rate and pumping head are achievable?

Hydraulic output for the Aussie QPT305SLT/L100M reaches up to 450 L/min in volumetric flow and up to 90 m in total head, depending on system duty.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed