Aussie Pumps Mr T QPT305SLTGX390E Aluminium 13HP Twin Impeller Firefighting Pump with Honda GX390E Petrol Engine
SKU: QPT305SLTGX390E

Aussie Pumps Mr T QPT305SLTGX390E Aluminium 13HP Twin Impeller Firefighting Pump with Honda GX390E Petrol Engine

$4,750.90 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Aussie Pumps
5 Years
Peace of Mind
Max Flow
500 L/Min
Max Head
95 m
Power
Honda GX390 Petrol Electric Start Engine
Ideal Use
Spray Irrigation

Product Overview

Rural fire protection authorities and civil dust abatement crews deploy the Aussie Mr T (QPT305SLTGX390E) electric start high volume twin impeller pump for emergency flood pumping, tall structure washdowns, and high pressure fire tanker operations. Electric key ignition allows rapid activation under stressful emergency conditions. The twin impeller assembly generates high pressure for driving long distance hose networks.

High elevation delivery volume achieves a maximum delivery rate of 500 L/min and develops a maximum elevation head of 95 m. Internal hydraulic architecture features a marine grade aluminium casing, twin closed aluminium impellers mounted on a single drive shaft, and a carbon ceramic mechanical seal with nitrile elastomers. Total equipment mass measures 70 kg in dry operating trim.

Mechanical drive is provided by a Honda GX390 13HP electric start petrol engine (battery supplied separately) producing 13 HP. Plumbing connections incorporate 3" BSP male inlet & 3" BSP male outlet with metal caps & chains, and the self-priming wet end achieves 7.6 m vertical suction lift. Rapid self-priming internal dynamics pick up fluid swiftly without requiring manual foot valves on suction lines.

Structural fully welded steel roll frame with battery tray & leads encloses the equipment while isolating mechanical vibration and simplifying site movement. The structural mount provides balance during transport across field vehicles, trailers, and utility trays. Complete spare parts support and factory technical documentation are accessible through Aussie Pumps distribution networks across Australia.

Features

  • High tensile marine grade aluminium casing resists corrosion through continuous water service.
  • Big belly priming chamber picks up prime fast from 7.6 m.
  • Precision matched dual aluminium impellers develop high discharge heads up to 95 m.
  • Full-bore 3-inch suction and discharge keep twin-impeller flow unrestricted.
  • The serviceable suction valve holds prime in the casing between jobs.
  • Backed by a 5-year pump end warranty from Aussie Pumps with 3-year Honda GX engine cover.
SPECIFICATIONS
Max Flow500 L/Min
Max Head95 m
PowerHonda GX390 Petrol Electric Start Engine
Suitable ForSpray Irrigation
Body MaterialMarine Grade Aluminium
Inlet Size80 mm
Outlet Size3-way (2 x 25 mm, 1 x 40 mm)
Warranty5 Years
Documents
Specification Data Sheet Download
Spare Parts Manual Download
Operating Manual Download
Troubleshooting Guide Download
Overhaul Instructions Download

On dedicated pastoral fire units, the Aussie Pumps Mr T Twin Impeller QPT305SLTGX390E initiates high-pressure water displacement via key start to supply distant uphill spray nozzles. The combination of wide intake porting, twin impellers, and electric starting provides dependable steep terrain protection.

  • Pastoral Fire Units
  • Uphill Spray Nozzles
  • Station Fire Defense
  • High Elevation Stations

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Data Sheet
Download
Spare Parts Manual
Download
Operating Manual
Download
Troubleshooting Guide
Download
Overhaul Instructions
Download
How quickly does the pump establish prime from low water sources?

The Aussie Pumps Mr T Twin Impeller (QPT305SLTGX390E) provides self-priming capability from up to 7.6 m vertical suction lift, picking up prime swiftly without requiring external line priming.

What manufacturer warranty periods protect this pump and motor?

Protection for the QPT305SLTGX390E includes a 5-year pump end warranty, 3-year Honda GX engine warranty, providing verified Australian warranty backing and technical support.

What engine powerhead and starter arrangement drive this unit?

Power for the QPT305SLTGX390E comes from a Honda GX390 13HP electric start petrol engine, equipped with an electric key start ignition for straightforward field deployment.

What inlet size and discharge port options come equipped on this unit?

Suction intake on the QPT305SLTGX390E is provided via 80 mm BSP threading, with delivery directed through 3-way (2 x 25 mm, 1 x 40 mm) BSP fittings.

What delivery volume and vertical lift limits are specified?

Hydraulic output for the Aussie QPT305SLTGX390E reaches up to 500 L/min in volumetric flow and up to 95 m in total head, depending on system duty.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us