Roll over image to zoom
SKU: RSE2BUV/2.2/240
Aussie Pumps RSE2BUV/2.2/240 Polyester 2" Ports Single Phase High-Head Chemical Transfer Pump with Protek Motor
Australia-Wide
(08) 9240 2992
Official Aussie Pumps
Peace of Mind
Product Overview
Aggressive single-phase chemical duty meets Viton in this 240 V 2-inch high-head electric poly pump, holding up to 580 litres a minute, shutting off at 22.5 metres through seals that resist the harshest shed chemicals. Viton protection on household supply. Harsh-chemistry single-phase transfer is RSE2BUV/2.2/240 with Viton seals fitted.
Maximum flow touches 580 L/min open discharge, shutting off at 22.5 m head (32 PSI). The 30% glass-filled polyester wet end runs the 706 impeller with Viton seals and 50 mm ports.
Household supply meets the toughest seal compound in the 2.2 kW single-phase 240 V Protek-protected motor driving the 28 kg pump. Aggressive shed chemistry runs through Viton across chemical transfer, diesel transfer and water transfer.
Use this electric configuration for fixed chemical transfer, diesel movement and general water-transfer work. It is suited to permanent shed, workshop, plant and tank-transfer layouts where different liquids must be moved through a dedicated electrically powered pumping point.
Features
- Compound-tough 2.2 kW 240 V single-phase motor with Protek drive faces the harshest shed chemicals on household supply.
- Peak flow of 580 L/min, shutting off at 22.5 m (32 PSI) holds pressure where standard seals fail.
- Shed-proof Viton sealing for aggressive media leads the range, with Buna N and EPDM options for milder duties.
- High-head 706 impeller in 30% glass-filled polyester delivers pressure in a compact 28 kg frame.
- Supply-proof 28 kg mounting weight installs anywhere a 240 V outlet exists.
- Compound cover with 5 years pump end and 1 year Melegari backs harsh-chemistry transfer.
- Covered by the 5 year Aussie Pumps pump end warranty and 1 year Melegari motor warranty.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What peak fluid displacement volume and vertical head are developed under full operating speed?
Discharge performance for the Aussie Pumps Electric Chemical RSE2 (RSE2BUV-2.2-240) yields an open flow volume of approximately 580 L/min and reaches a maximum shut-off elevation of approximately 22.5 m.
How do the wide internal waterways clear slurry runoff without choking the suction eye during dirty liquid transfer?
Built for clean chemical and water transfer, internal waterways on the RSE2BUV 2.2 240 are optimized for liquid solutions free of abrasive solid debris.
How is electrical drive power delivered to turn the pump shaft on site within outdoor switchboard setups?
Direct electrical drive on the RSE2BUV/2.2/240 features a motor rated at 2.2 kW 240V 1-Phase, built for steady site connection.
How does internal casing geometry evacuate suction line air during dry starts when drafting from deep sumps?
Built-in priming passages on the RSE2BUV/2.2/240 draw fluid vertically from depths up to 7.6 m without requiring an external foot valve once the casing is filled.
Why do agricultural spray operators select polypropylene for chemical decanting setups without corroding from harsh liquid fertilizers?
Molded from glass-reinforced polypropylene, the RSE2 (RSE2BUV/2.2/240) withstands harsh agricultural chemicals, liquid feeds, and corrosive fertilizers.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us