Calpeda BS2F 2MXH 1606 Three Phase 2 x 4kW Fixed Speed Twin Pump Multistage Booster System
SKU: BS2F 2MXH 1606*

Calpeda BS2F 2MXH 1606 Three Phase 2 x 4kW Fixed Speed Twin Pump Multistage Booster System

$23,294.70 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Calpeda
24 Months
Peace of Mind
Max Flow
833 L/Min
Max Head
68 m
Power
2 x 4 kW / 415v
Ideal Use
Industrial & Commercial Pressure Boosting

Product Overview

Tall commercial risers and pressurised process lines require extra vertical lift to keep upper-level fixtures flowing consistently. Built around two Calpeda MXH 1606 horizontal multistage pumps, the BS2F 2MXH 1606 packaged booster station supplies up to 833.4 L/Min of combined flow. To overcome static elevation and pipe friction, the wet end can generate up to 68 m of head. Its twin-pump configuration provides dependable hydraulic redundancy and high-pressure stability across hospitals, multi-level residential towers, and commercial plant rooms.

Discharge line regulation is managed by calibrated differential pressure switches feeding directly into an onboard microprocessor control board. When a tap or valve opens, the primary pump engages to satisfy baseline demand, and the secondary unit steps in automatically if pressure continues to dip under heavy draw-off. Sequential duty sharing swaps the lead role between both pumps on subsequent starts, while anti-cycling timers eliminate nuisance chattering across the contactors.

All wetted collection pipework features hygienic stainless steel AISI 304 suction and delivery headers engineered for low friction loss. Plumbers can connect building mains directly to the 80 mm inlet manifold and route boosted water through the 65 mm outlet header. Integrated isolation ball valves and non-return check valves simplify individual pump servicing, while a dial pressure gauge and a dedicated mounting point for an external accumulator vessel streamline commissioning.

Energizing the booster skid requires a three-phase 415 V electrical feed matched to high-efficiency motors rated at three-phase 400/690 V. Both 2-pole induction units operate at a synchronous speed near 2900 rpm at 50 Hz, with each motor producing 4 kW (P2) of mechanical output and drawing 5.5 A at full load. Built in strict compliance with IEC 60034 standards and protected by Class F insulation, these drives endure demanding duty cycles.

Key Features

  • High-Head Impeller Stack: Utilises a precision 6-stage hydraulic assembly in each pump to overcome tall static heads and long pipe runs.
  • Microprocessor Sequencing: Coordinates differential pressure switches to stage the second pump online only when flow demand exceeds single-pump capacity.
  • Balanced Wear Cycling: Alternates lead and standby pump assignments automatically to prevent premature bearing and mechanical seal fatigue.
  • AISI 304 Stainless Headers: Resists corrosion and thermal stress across the suction and discharge manifolds in commercial hot and cold water loops.
  • Independent Branch Isolation: Equipped with heavy-duty ball valves and non-return valves so maintenance never forces a total building shutdown.
  • Wide Thermal Operating Window: Engineered to pump liquids reliably across temperatures ranging from -15 °C to +110 °C without performance degradation.
  • Dust and Splash Defence: Protected to IP54 ingress standards, keeping electrical terminals and motor windings safe in damp mechanical rooms.
  • Turnkey Plant Assurance: Arrives fully assembled on a steel skid frame and supported by a 24 Months warranty for long-term peace of mind.

What's Included

  • 2 x Calpeda MXH 1606 horizontal multistage pumps
  • Stainless steel AISI 304 suction manifold
  • Stainless steel AISI 304 delivery manifold
  • Isolation ball valves
  • Non-return valves
  • Microprocessor control board with differential pressure switches
  • System pressure gauge
  • Factory assembled and tested boosting plant
  • Supports a 1000 L galvanised diaphragm expansion tank
SPECIFICATIONS
Max Flow833 L/Min
Max Head68 m
Power2 x 4 kW / 415v
Rated Current2 x 5.5 Amps
Suitable ForIndustrial & Commercial Pressure Boosting
Body Material304 Stainless Steel
Liquid Temperature-15 °C to +110 °C
Inlet Size80 mm
Outlet Size65 mm
Warranty24 Months
Documents
Specification Data Sheet Download
Product Brochure Download

Large secondary boarding schools operate the Calpeda BS2F 2MXH 1606 to feed central residential dormitories and dining hall dishwashers. Automatic dual pump sequencing handles simultaneous student bathroom use steadily, eliminating cold water pressure drops across upper dorm floors.

  • Boarding School Boosting
  • Dormitory Block Pressurisation
  • Dining Hall Supply
  • Campus Water Distribution

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Data Sheet
Download
Product Brochure
Download
At what combined peak discharge rate can this twin pump horizontal package operate?

Twin multistage impellers on the Calpeda Fixed Speed Booster Set BS2F 2MXH 1606 combine to discharge a collective peak capacity of 833.4 L/min (50 m³/h) for major facilities.

Which electrical power mains and automated motor control board regulate this booster set?

Coordinated by an alternating sequencing console, the BS2F 2MXH 1606 utilizes twin three phase 400V motors delivering a combined 8 kW output.

Under what maximum static head elevation and line pressure limits does this package operate?

Hydraulic pressure testing certifies the BS2F-2MXH-1606 for up to 68 metres of elevation head and a maximum casing pressure of 8 bar across -15°C to +110°C.

What corrosion proof wetted metallurgy and manifold connection thread sizes are incorporated?

Manufactured with AISI 304 chromium-nickel stainless steel wetted components, the BS2F 2 MXH 1606 is mounted on a Zinc-plated Steel S235JR baseplate and fitted with isolating ball valves, non-return valves, and G 3 suction with G 2 1/2 delivery manifolds.

What manufacturer warranty protection coverage supports this fixed speed pumping assembly?

Calpeda manufacturer warranty coverage defends the 2MXH 1606 (BS2F 2MXH 1606), providing comprehensive defect protection for the stainless pump wet end, electric motor, and automated control console from date of invoice.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed