Max Flow
433 L/Min
Max Head
109 m
Power
2 x 4 kW / 415v
Ideal Use
Industrial Process Water Supply

Product Overview

Maintaining uniform delivery pressure across extensive commercial developments demands steady and balanced hydraulic support. Built with 2 Calpeda MXV 40-910 vertical multistage pumps operating in a parallel staging arrangement, this variable-speed twin package ensures continuous pressure stability. At peak consumption, the dual-pump configuration produces a peak volumetric flow rate of 433 L/Min to sustain commercial operations. Under closed-valve conditions, the vertical multistage stacks develop a maximum shut-off head of 109 m to overcome vertical building height.

Precise setpoint pressure is sustained across fluctuating facility draw through an integrated motor-mounted Calpeda I-MAT variable frequency converter. An electronic pressure transducer continuously feeds line data to the integrated controller, modulating pump speed to deliver exact flow requirements without pressure spikes. Smooth soft-start and soft-stop ramp profiles protect building distribution pipework from mechanical water hammer and sudden pressure waves. Built-in electronic monitoring systems deliver automatic safety shutdown protection in the event of dry-run conditions, electrical phase imbalance, or motor overload.

Built with high-grade AISI 304 stainless steel metallurgy, the internal impellers, stage chambers, outer sleeves, and pump bodies provide exceptional operational durability. Hydraulic flow distributes through common AISI 304 stainless steel manifolds with standardized 65 mm suction and 65 mm delivery fittings with G 2 1/2" BSP. Independent isolation valves and check valves service each pump run, mounted alongside an analog delivery pressure gauge upon an AISI 304 stainless steel baseplate frame.

Synchronous mechanical output is supplied by two 2-pole commercial induction motors matched to Australian three-phase 400 V (50 Hz) power standards. Rotating at a nominal operating speed of 2900 rpm, the twin motor assembly delivers 2 x 4 kW of total drive power while drawing a rated full-load current of 2 x 8.1 Amps. High-efficiency motor design maintains balanced electrical consumption and robust mechanical performance across varying commercial pressure demands.

Key Features

  • Synchronized dual vertical multistage 10-stage hydraulic wet ends operate in parallel to produce smooth and balanced line pressure.
  • An integrated motor-mounted Calpeda I-MAT variable frequency converter continuously modulates operating speed to sustain exact setpoint pressure.
  • Heavy-duty AISI 304 stainless steel pump casings, intermediate stage chambers, and impellers ensure superior corrosion resistance.
  • Weatherproof electric motor enclosures are sealed to IP55 standards with Class F thermal winding insulation for demanding plant room environments.
  • Verified operating limits safely circulate clean commercial liquids across a working temperature spectrum of -15 °C to +110 °C.
  • Controlled acceleration and deceleration ramp profiles eliminate sudden pressure spikes and safeguard building pipework from water hammer.
  • Integrated digital safety electronics provide automated shutdown protection against dry-running, motor overcurrent, and electrical supply faults.
  • Standardized G 2 1/2" BSP manifold connections simplify mechanical alignment and expedite site pipework installation.
  • Automated duty assist rotation equalizes operating run hours across both pumps to prevent uneven component wear.
  • Covered by a 24-month manufacturer warranty.

What's Included

  • 2 x Calpeda MXV 40-910 vertical multistage pumps
  • 1 x Motor-mounted Calpeda I-MAT variable frequency converter with motor adapter and interconnect cabling
  • 1 x Factory-mounted 18 L membrane pressure vessel on delivery manifold
  • 1 x AISI 304 stainless steel suction manifold with individual isolation ball valves and non-return valves
  • 1 x AISI 304 stainless steel delivery manifold with individual isolation ball valves and visual pressure gauge
  • 1 x Digital electronic pressure transducer pre-wired to the I-MAT inverter system
  • 1 x Heavy-duty AISI 304 stainless steel structural mounting baseplate
SPECIFICATIONS
Max Flow433 L/Min
Max Head109 m
Power2 x 4 kW / 415v
Rated Current2 x 8.1 Amps
Suitable ForIndustrial Process Water Supply
Body Material304 Stainless Steel
Liquid Temperature-15°C to +110°C
Inlet Size65 mm
Outlet Size65 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Data Sheet Download
Operating Instructions Download
I-MAT Operating Instructions Download
Spare Parts Exploded View Download

Commercial property maintenance teams specify the Calpeda BS2V 2MXV 40-910-ITT twin booster set for balanced water pressure distribution across multi-level infrastructure. Built with 2 x Calpeda MXV 40-910 vertical multistage pump assemblies, the package delivers a maximum volumetric flow rate of 433 L/min to overcome sudden demand spikes across commercial pipework. The high-efficiency vertical hydraulic stacks produce a maximum shut-off head of 109 metres to maintain constant vertical static elevation without line starvation.

  • High-Flow Commercial Water Boosting
  • Multi-Tower Building Water Supply
  • Centralized Potable Water Reticulation
  • Commercial Industrial Water Boosting

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Data Sheet
Download
Operating Instructions
Download
I-MAT Operating Instructions
Download
Spare Parts Exploded View
Download
What power supply and variable frequency converter modulate this twin vertical set?

Electric motor propulsion on the Calpeda BS2V 2MXV 40-910-ITT Variable Speed Booster Set with I-MAT Three Phase utilizes Three Phase 400 V power at 50 Hz to drive twin 4 kW (5.5 HP) motors totaling 8 kW, coordinated by an integrated Calpeda I-MAT variable frequency converter.

Under what maximum static head elevation and line pressure limits does this package operate?

Developing up to 109 metres of maximum static head, the BS2V 2MXV 40-910-ITT sustains internal casing pressures up to 25 bar across fluid operating temperatures from -15 °C to +110 °C.

What corrosion proof wetted metallurgy and common manifold connection sizes are incorporated?

Wetted construction on the BS2V-2MXV-40-910-ITT combines AISI 304 chromium-nickel stainless steel, AISI 304 stainless steel impellers, and Hard Metal-Carbon-EPDM mechanical seals seated on a Zinc-plated Steel S235JR Baseplate, linked by G 2 1/2" BSP suction and G 2 1/2" BSP delivery common manifolds.

What manufacturer warranty protection coverage supports this twin variable speed pumping assembly?

The BS2V 2MXV 40-910-ITT variable speed booster set is protected by a 24-month manufacturer warranty.

What peak water discharge rate and maximum parallel flow capacity does this package supply?

To accommodate heavy site consumption, the 2MXV 40-910-ITT provides up to 433.4 L/min (26 m³/h) across twin pumps under automated variable speed coordination.