Product Overview
Elevated sanitary risers depend on continuous pressure regulation to prevent fixture starvation. The Calpeda BS3V 3MXV 50-2003-ITT triplex system incorporates 3 Calpeda MXV 50-2003 vertical multistage pumps in parallel to deliver balanced circulation across high-rise hotel infrastructure and multi-zone guest floor water risers. Operating against closed pipework, the multistage wet ends produce a maximum shut-off head of 41.4 m for static elevation. When demand reaches operational peaks, the parallel pumping assembly achieves a maximum delivery capacity of 1400 L/Min across distribution outlets.
Automated pressure regulation is governed by a motor-mounted Calpeda I-MAT variable frequency converter operating the three pumps in coordinated duty-assist staging. Stepless speed modulation continuously matches rotational velocity to instantaneous line demand, maintaining constant pressure while maximizing electrical efficiency. Gradual acceleration ramps eliminate disruptive hydraulic surges, protecting building pipework and inline fittings from mechanical water hammer stresses. Comprehensive digital diagnostics incorporate automated shut-off protection to safeguard the pumping assembly against dry running, phase loss, and overcurrent conditions.
Manufactured with AISI 304 stainless steel wet ends, the vertical multistage pumps include stainless steel casings, intermediate diffuser stages, impellers, and wear sleeves. Three vertical pumps couple directly to rigid AISI 304 stainless steel headers with 80 mm suction and 80 mm discharge ports equipped with G 3" BSP threaded fittings. Individual isolation ball valves and non-return check valves protect each branch, supported by an analog line pressure gauge on an AISI 304 stainless steel mounting base.
Power is provided by three heavy-duty 2-pole induction motors designed for continuous operation on Australian three-phase 400 V (50 Hz) electrical distribution networks. Running synchronously at 2900 rpm, the electric drives generate 3 x 3 kW of mechanical output with a rated operational full-load current draw of 3 x 6.2 Amps. High-grade electrical laminations and Class F thermal insulation deliver long-term mechanical reliability across continuous commercial duty cycles.
Key Features
- Triplex vertical multistage configuration with three Calpeda MXV 50-2003 3-stage pumps maintains continuous line pressure stability.
- Motor-mounted Calpeda I-MAT frequency converter continuously modulates operating speed to maintain target line pressure.
- Heavy-duty AISI 304 stainless steel pump casings, intermediate stage chambers, and impellers ensure superior corrosion resistance.
- Totally enclosed fan-cooled electric motors feature IP55 ingress protection and Class F thermal insulation for harsh commercial duties.
- Thermal operating envelope safely accommodates clean liquid media ranging from -15 °C to +110 °C.
- Controlled motor ramping curves prevent abrupt pressure spikes and protect building distribution lines from hydraulic shock.
- Integrated digital safety electronics provide automated shutdown protection against dry-running, motor overcurrent, and electrical supply faults.
- Common stainless steel manifolds with DN 100 Table E flanged connections ensure rigid mechanical alignment and easy installation.
- Coordinated duty-assist staging balances operational run hours across the three pumps for uniform long-term component wear.
- Protected by a 24-month manufacturer warranty.
What's Included
- 3 x Calpeda MXV 50-2003 vertical multistage pumps
- 3 x Motor-mounted Calpeda I-MAT variable frequency converters with motor adapters and interconnect cabling
- 1 x Factory-mounted 18 L membrane pressure vessel on delivery manifold
- 1 x AISI 304 stainless steel suction manifold with individual isolation ball valves and non-return valves
- 1 x AISI 304 stainless steel delivery manifold with individual isolation ball valves and visual pressure gauge
- 1 x Digital electronic pressure transducer pre-wired to the I-MAT inverter system
- 1 x Heavy-duty zinc-plated structural steel (S235JR) mounting baseplate
SPECIFICATIONS
| Max Flow | 1400 L/Min |
| Max Head | 41.4 m |
| Power | 3 x 3 kW / 415v |
| Rated Current | 3 x 6.2 Amps |
| Suitable For | Commercial Building Reticulation Systems |
| Body Material | 304 Stainless Steel |
| Liquid Temperature | -15°C to +110°C |
| Inlet Size | 100 mm |
| Outlet Size | 100 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What three phase power requirements and frequency drives operate this triple assembly?
Communicating inverter drives on the Calpeda BS3V 3MXV 50-2003-ITT Variable Speed Booster Set with I-MAT (Three Phase 400V) utilize Three Phase 400 V power at 50 Hz to drive three 3 kW (4 HP) motors totaling 9 kW, coordinated by three communicating Calpeda I-MAT inverters.
Under what maximum static head elevation and line pressure limits does this three-pump package operate?
Developing up to 41.4 metres of maximum static head, the BS3V 3MXV 50-2003-ITT sustains internal casing pressures up to 25 bar across fluid operating temperatures from -15 °C to +110 °C.
What corrosion proof wetted metallurgy and common manifold connection sizes are incorporated?
Wetted construction on the BS3V-3MXV-50-2003-ITT combines AISI 304 chromium-nickel stainless steel pump casings, AISI 304 stainless steel impellers, and Hard Metal-Carbon-EPDM mechanical seals seated on a Zinc-plated Steel S235JR Baseplate, linked by DN 100 Flanged suction and DN 100 Flanged delivery common manifolds.
What manufacturer warranty protection coverage supports this triple variable speed pumping assembly?
Warranty protection supporting the BS3V 3 MXV 50 2003 ITT encompasses full Calpeda coverage for the three vertical multistage pump wet ends, triple electric motors, and three electronic inverter consoles against manufacturing defects from date of invoice.
What peak water discharge rate and maximum parallel flow capacity does this triple package supply?
To accommodate heavy site consumption, the 3MXV 50-2003-ITT provides up to 1400 L/min (84 m³/h) across three pumps under automated variable speed coordination, with each unit rated to 466.7 L/min (28 m³/h).