Davey Monsoon Light VM10-6 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank
SKU: 2MLV10-6M3-18

Davey Monsoon Light VM10-6 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank

$0.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Davey
24 Months
Peace of Mind
Max Flow
466 L/Min
Max Head
65 m
Power
2 x 2.2 kW / 415v
Ideal Use
Commercial Complex & Shopping Centre Water Boosting

Product Overview

Convention centres and indoor exhibition halls maintain line pressure during surge periods through the Davey Monsoon Light dual pump booster set. Configured with dual parallel vertical multistage pumps on a unified skid, the assembly balances incoming water supply across expanding multi-zone networks. Automatic duty-assist and lead-lag alternation stage both pumps dynamically to prevent pressure dropouts across elevated plumbing risers.

Sized to master demanding trade cycles, combined fluid throughput expands up to 466 L/min (28 m³/h), with 233 L/min per pump. Across vertical distribution risers, each 6-stage Davey VM10-6 hydraulic stack generates up to 65.7 metres of maximum shut-off head. Internal impellers, stage diffusers, and outer sleeves are constructed from AISI 304 stainless steel with a 316L stainless steel pump shaft to preserve clean water quality. Cartridge silicon carbide, carbon, and EPDM mechanical seals pair with PN25 (16 bar) rated wet ends for high-pressure containment.

Power transmission is delivered via dual precision induction motors matched to variable frequency operation. Speed regulation is governed by dual variable frequency drives operating in synchronized lead-lag and parallel cascade staging to hold constant line pressure. The three-phase electrical system connects to a 415V supply at 50 Hz, powering twin 2.2 kW TEFC motors with a rated current draw of 2 x 4.3 Amps. Factory-plumbed stainless steel headers incorporate DN80 (80 mm) AS2129 Table E flanged manifold ports alongside DN40 (40 mm) individual pump flanges, rated for system water temperatures from 0°C to 40°C.

The pre-commissioned assembly is secured to a heavy-gauge structural mounting baseplate. Integrated elastomeric machine mounts isolate rotational vibration, protecting connected manifold pipework from mechanical stress while a factory-mounted 18L diaphragm tank buffers line draw. Assembled and hydrostatically tested to Australasian building plumbing standards, the package is supported by nationwide Davey service agents and spare parts availability.

FEATURES

  • AISI 304 stainless steel impellers and stage chambers with 316L stainless steel shafts
  • Factory-plumbed suction and delivery manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports and DN40 (40 mm) pump flanges
  • Twin 2.2 kW three-phase IE3 high-efficiency TEFC electric motors
  • Maximum vertical shut-off delivery head up to 65.7 metres
  • Integrated 18L 10bar flow-through diaphragm pressure vessel to buffer system pressure
  • Dual variable speed inverter drives with automatic duty-assist and cyclical lead-lag alternation
  • Permissible system clean liquid operating temperature range from 0°C to 40°C
  • Combined parallel peak water delivery flow up to 466 L/min (28 m³/h) or 233 L/min per pump
  • Three-phase 415V, 50 Hz electrical operation drawing 2 x 4.3 Amps full load current
  • Dual parallel Davey VM10-6 vertical multistage pumps featuring 6 hydraulic stages per pump
  • Cartridge silicon carbide, carbon, and EPDM mechanical seals rated to PN25 (16 bar)
  • Backed by Davey 2-year pump wet end warranty and 2-year variable speed inverter drive warranty against manufacturing defects

What's Included

  • Davey Monsoon Light Packaged Twin Pump Booster Skid
  • 2 x Davey VM10-6 Vertical Multistage Pumps with Variable Speed Inverter Drives
  • 1 x Factory-Mounted 18L 10bar Diaphragm Pressure Tank
  • Suction and Delivery Manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports
  • Individual Suction and Discharge Isolation Ball Valves and Non-Return Check Valves
  • Dual Pressure Transducers and Visual System Pressure Gauge
  • Rigid Structural Steel Mounting Baseplate with Vibration Isolation Mounts
  • Manufacturer Installation and Operating Instructions
SPECIFICATIONS
Max Flow466 L/Min
Max Head65 m
Power2 x 2.2 kW / 415v
Rated Current2 x 4.3 Amps
Suitable ForCommercial Complex & Shopping Centre Water Boosting
Body Material304 Stainless Steel
Liquid Temperature-15°C to +120°C
Inlet Size80 mm
Outlet Size80 mm
Warranty24 Months
Documents
Specification Datasheet Download
VM Series Pumps Datasheet Download
Monsoon MLV IQ2 Brochure Download
Installation Instructions Download

Retirement care wings commission the 2MLV10-6M3-18 twin booster unit to feed hot water distribution loops and ensuite bathroom fixtures. Precision dual variable speed inverters eliminate sudden line pressure shifts, allowing elderly residents to enjoy safe, steady water delivery during morning routines.

  • Feeding care risers
  • Supplying ensuite fixtures
  • Eliminating pressure shifts
  • Delivering safe water

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
VM Series Pumps Datasheet
Download
Monsoon MLV IQ2 Brochure
Download
Installation Instructions
Download
What is the maximum static discharge head and operating pressure of this twin booster?

Static head development on the Davey Monsoon Light VM10-6 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank attains a maximum static shut-off head of 65.7 metres across 6 stages per pump with a PN25 or 16 bar pressure rating, handling system water from 0 deg C to 40 deg C.

What pipe connection diameters, internal metals, and diaphragm tank are included?

Constructed with 304 stainless steel stages and impellers on a structural steel skid, the 2MLV10-6M3-18 incorporates silicon carbide mechanical seals, DN80 80 mm AS2129 Table E flanged manifold ports with DN40 40 mm pump flanges, and an 18L 10bar pressure tank.

What factory warranty periods apply to the hydraulic wet end and speed drive?

Factory warranty provisions for the 2MLV-10-6M3-18 cover both the hydraulic pump wet ends and the variable speed drives for 2 years against manufacturing defects.

What peak water delivery volume can this twin variable speed system discharge?

Rated for combined volumetric throughput, the 2MLV 10 6M3 18 yields up to 466 L/min or 28 m3/h with twin pumps active, each delivering up to 233 L/min or 14 m3/h to hold constant line pressure.

What mains voltage supply and electronic frequency drives regulate this package?

Mains supply parameters for the VM10-6 (2MLV10-6M3-18) specify Three Phase 415V at 50 Hz to operate twin 2.2 kW motors drawing 2 x 4.3 Amps regulated by integrated dual inverter electronics.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed