Hydraulic contractors select the pre-assembled architecture of the Davey Monsoon Light vertical multistage booster package. Equipped with a vertical multistage pump assembly, the unit sustains line pressure stability across demanding plumbing lines. This packaged assembly supplies an integrated booster solution to prevent pressure dropouts across elevated risers.
Engineered for low internal friction losses, discharge capacity peaks at 383 L/min. Across elevated vertical distribution lines, the multistage hydraulic wet end generates up to 201 metres of maximum shut-off head to overcome static elevation losses. Internal impellers and intermediate stage diffusers are manufactured from AISI 304 stainless steel to maintain fluid purity and hydraulic efficiency. A hard-faced mechanical seal and reinforced casing construction support operating system pressures up to 25 bar (2,500 kPa PN25).
Propulsion is provided by an electric motor designed to sustain high continuous torque. Speed regulation is governed by an integrated variable frequency drive controller, continuously matching motor speed to instantaneous draw to stabilize pipeline pressure. The electrical package connects to a 415V supply at 50 Hz drawing a rated current of 21.4 Amps. Pre-plumbed hydraulic connections feature standardized 2" BSP ports, rated for clean liquid operating temperatures from 0°C to 40°C.
Engineered for simple plant room integration, the package rests upon a rigid mounting platform. Integrated elastomeric mounts isolate pump vibrations, protecting connected distribution pipework from mechanical stress and acoustic transmission. Engineered and assembled to meet demanding Australasian commercial plumbing standards, the system benefits from comprehensive Davey technical support and readily available nationwide spare parts.
FEATURES
- Peak volumetric clean water delivery flow up to 383 L/min
- Electrical supply rating of 415V at 50 Hz
- Wetted internal components precision crafted from AISI 304 stainless steel
- Maximum casing operating pressure rating of 25 bar (2,500 kPa PN25)
- Rated full load electrical current draw of 21.4 Amps
- Vertical multistage Davey VM15-14 pump wet end featuring 14 stages
- Integrated variable speed inverter drive modulating speed to maintain constant line pressure
- Maximum vertical delivery shut-off head up to 201 metres
- Factory-fitted 24L diaphragm pressure tank to absorb hydraulic shock
- Pre-plumbed suction and delivery manifolds with standardized 2" BSP pipe connections
- Permissible clean liquid operating temperature range from 0°C to 40°C
- Backed by Davey 5-year pump end warranty and 2-year inverter drive warranty
What's Included
- Davey 1MLV Commercial Packaged Booster Skid
- 1 x Davey VM15-14 Vertical Multistage Pump with Variable Frequency Drive
- 1 x Factory-Mounted 24L Diaphragm Pressure Vessel
- Suction and Delivery Manifolds with Standardized 2" BSP Connections
- Individual Isolation Ball Valves and Spring-Loaded Non-Return Check Valves
- Factory-Calibrated Digital Pressure Transducer and Visual Pressure Gauge
- Rigid Structural Steel Mounting Baseplate Frame
- Comprehensive Manufacturer Technical Manual and Installation Guide
SPECIFICATIONS
| Max Flow | 383 L/Min |
| Max Head | 201 m |
| Power | 11 kW / 415v |
| Rated Current | 21.4 Amps |
| Suitable For | High-Rise Industrial Reticulation & Manufacturing Supply |
| Body Material | 304 Stainless Steel |
| Liquid Temperature | -15°C to +120°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
By what electronic drive mechanism is motor velocity controlled on this pump?
Electric propulsion features on the Davey Monsoon Light VM15-14 Three Phase 11kW Variable Speed Booster Pump Set with 24L Tank utilize Three Phase 415V electrical supply at 50 Hz, powering a 11 kW motor drawing 21.4 Amps under integrated variable speed inverter control.
What shut off head elevation and maximum casing pressure rating apply to this unit?
Developing up to 201 metres of maximum static head, the 1MLV15-14M3-24HP sustains casing pressures up to PN25 (25 bar) across fluid temperatures up to 90 deg C.
Which construction materials, hydraulic connection sizes, and pressure vessel are standard?
Wetted construction on the 1MLV-15-14M3-24HP combines 304 stainless steel hydraulic components seated on a mounting chassis, linked by DN50 (50 mm) flanged ports and a 24L 25bar expansion tank.
Which warranty terms cover the pump wet end and variable frequency inverter?
Warranty protection supporting the 1MLV 15 14M3 24HP encompasses official Davey coverage including 2 years on both the pump wet end and the variable speed drive unit against manufacturing defects.
What maximum fluid delivery volume can this multistage pump package maintain?
To satisfy heavy site water demand, the VM15-14 (1MLV15-14M3-24HP) provides up to 383 L/min (23.0 m3/h) modulated by electronic frequency control.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us