Davey Monsoon Light VM15-14 Three Phase 11kW Variable Speed Twin Pump Booster Set with 24L Tank
SKU: 2MLV15-14M3-24HP

Davey Monsoon Light VM15-14 Three Phase 11kW Variable Speed Twin Pump Booster Set with 24L Tank

$0.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Davey
24 Months
Peace of Mind
Max Flow
766 L/Min
Max Head
201 m
Power
2 x 11 kW / 415v
Ideal Use
High-Rise Industrial Reticulation & Manufacturing Supply

Product Overview

Constructed to deliver years of consistent service, the Davey Monsoon Light twin pump system represents Davey hydraulic engineering. Configured with dual parallel vertical multistage pumps on a unified skid, the assembly balances incoming water supply across expanding multi-zone networks. Automatic duty-assist and lead-lag alternation stage both pumps dynamically to prevent pressure dropouts across elevated plumbing risers.

Designed to feed multiple remote branch lines, total parallel capacity scales to 766 L/min (46 m³/h), or 383 L/min per pump. Across vertical distribution risers, each 14-stage Davey VM15-14 hydraulic stack generates up to 201 metres of maximum shut-off head. Internal impellers, stage diffusers, and outer sleeves are constructed from AISI 304 stainless steel with a 316L stainless steel pump shaft to preserve clean water quality. Cartridge silicon carbide, carbon, and EPDM mechanical seals pair with PN25 (25 bar) rated wet ends for high-pressure containment.

The electric drive system incorporates dual efficient motors designed for quiet mechanical power. Speed regulation is governed by dual variable frequency drives operating in synchronized lead-lag and parallel cascade staging to hold constant line pressure. The three-phase electrical system connects to a 415V supply at 50 Hz, powering twin 11 kW TEFC motors with a rated current draw of 2 x 21.4 Amps. Factory-plumbed stainless steel headers incorporate DN80 (80 mm) AS2129 Table E flanged manifold ports alongside DN50 (50 mm) individual pump flanges, rated for system water temperatures from 0°C to 40°C.

Factory assembly aligns the twin pump assembly on a rigid, vibration-absorbing steel base. Integrated elastomeric machine mounts isolate rotational vibration, protecting connected manifold pipework from mechanical stress while a factory-mounted 24L diaphragm tank buffers line draw. Assembled and hydrostatically tested to Australasian building plumbing standards, the package is supported by nationwide Davey service agents and spare parts availability.

FEATURES

  • Factory-plumbed suction and delivery manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports and DN50 (50 mm) pump flanges
  • Maximum vertical shut-off delivery head up to 201 metres
  • Dual parallel Davey VM15-14 vertical multistage pumps featuring 14 hydraulic stages per pump
  • Twin 11 kW three-phase IE3 high-efficiency TEFC electric motors
  • Dual variable speed inverter drives with automatic duty-assist and cyclical lead-lag alternation
  • Cartridge silicon carbide, carbon, and EPDM mechanical seals rated to PN25 (25 bar)
  • Three-phase 415V, 50 Hz electrical operation drawing 2 x 21.4 Amps full load current
  • Combined parallel peak water delivery flow up to 766 L/min (46 m³/h) or 383 L/min per pump
  • Permissible system clean liquid operating temperature range from 0°C to 40°C
  • Integrated 24L 25bar flow-through diaphragm pressure vessel to buffer system pressure
  • AISI 304 stainless steel impellers and stage chambers with 316L stainless steel shafts
  • Backed by Davey 2-year pump wet end warranty and 2-year variable speed inverter drive warranty against manufacturing defects

What's Included

  • Davey Monsoon Light Packaged Twin Pump Booster Skid
  • 2 x Davey VM15-14 Vertical Multistage Pumps with Variable Speed Inverter Drives
  • 1 x Factory-Mounted 24L 25bar Diaphragm Pressure Tank
  • Suction and Delivery Manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports
  • Individual Suction and Discharge Isolation Ball Valves and Non-Return Check Valves
  • Dual Pressure Transducers and Visual System Pressure Gauge
  • Rigid Structural Steel Mounting Baseplate with Vibration Isolation Mounts
  • Manufacturer Installation and Operating Instructions
SPECIFICATIONS
Max Flow766 L/Min
Max Head201 m
Power2 x 11 kW / 415v
Rated Current2 x 21.4 Amps
Suitable ForHigh-Rise Industrial Reticulation & Manufacturing Supply
Body Material304 Stainless Steel
Liquid Temperature-15°C to +120°C
Inlet Size80 mm
Outlet Size80 mm
Warranty24 Months
Documents
Specification Datasheet Download
VM Series Pumps Datasheet Download
Monsoon MLV IQ2 Brochure Download
Installation Instructions Download

Police precinct headquarters install the 2MLV15-14M3-24HP vertical twin booster to feed holding cell sanitation fixtures and administrative office risers. Dual stainless steel pump wet ends provide redundant water delivery, maintaining mandated hygiene pressure levels across secure custodial areas.

  • Feeding cell fixtures
  • Supplying office risers
  • Delivering secure water
  • Maintaining hygiene levels

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
VM Series Pumps Datasheet
Download
Monsoon MLV IQ2 Brochure
Download
Installation Instructions
Download
What motor power rating and electrical mains voltage operate this twin pump package?

Variable frequency control on the Davey Monsoon Light VM15-14 Three Phase 11kW Variable Speed Twin Pump Booster Set with 24L Tank utilizes Three Phase 415V electrical supply at 50 Hz, powering twin 11 kW IE3 motors drawing 2 x 21.4 Amps under dual variable speed inverter control.

How many metres of vertical head can this multistage hydraulic wet end generate?

Developing up to 201 metres of maximum static head across 14 stages per pump, the 2MLV15-14M3-24HP sustains PN25 or 25 bar working pressure across liquid temperatures from 0 deg C to 40 deg C.

What pipe connection diameters, internal metals, and diaphragm tank are included?

Wetted construction on the 2MLV-15-14M3-24HP combines 304 stainless steel hydraulic components and 316L shafts seated on a mounting skid, linked by DN80 80 mm AS2129 Table E flanged manifold ports, DN50 50 mm pump ports, and a 24L 25bar expansion tank.

What factory warranty periods apply to the hydraulic wet end and speed drive?

Warranty protection supporting the 2MLV 15 14M3 24HP encompasses official Davey coverage including 2 years on both the pump wet ends and the variable speed drive units against manufacturing defects.

What peak water delivery volume can this twin variable speed system discharge?

To satisfy heavy site water demand, the VM15-14 (2MLV15-14M3-24HP) provides up to 766 L/min or 46 m3/h across dual parallel pumps, or up to 383 L/min per pump under variable speed coordination.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed