Roll over image to zoom
SKU: 2MLV15-8M3-18HP
Davey Monsoon Light VM15-8 Three Phase 7.5kW Variable Speed Twin Pump Booster Set with 18L Tank
Australia-Wide
(08) 9240 2992
Official Davey
Peace of Mind
Product Overview
In modern building services, the Davey Monsoon Light twin pump booster delivers integrated variable-speed staging with compact layout. Configured with dual parallel vertical multistage pumps on a unified skid, the assembly balances incoming water supply across expanding multi-zone networks. Automatic duty-assist and lead-lag alternation stage both pumps dynamically to prevent pressure dropouts across elevated plumbing risers.
The precision multistage impellers generate combined parallel delivery flows up to 766 L/min (46 m³/h), or 383 L/min per pump. Across vertical distribution risers, each 8-stage Davey VM15-8 hydraulic stack generates up to 112 metres of maximum shut-off head. Internal impellers, stage diffusers, and outer sleeves are constructed from AISI 304 stainless steel with a 316L stainless steel pump shaft to preserve clean water quality. Cartridge silicon carbide, carbon, and EPDM mechanical seals pair with PN25 (16 bar) rated wet ends for high-pressure containment.
The drive train features dual industrial electric motors designed for uninterrupted plant room uptime. Speed regulation is governed by dual variable frequency drives operating in synchronized lead-lag and parallel cascade staging to hold constant line pressure. The three-phase electrical system connects to a 415V supply at 50 Hz, powering twin 7.5 kW TEFC motors with a rated current draw of 2 x 14.6 Amps. Factory-plumbed stainless steel headers incorporate DN80 (80 mm) AS2129 Table E flanged manifold ports alongside DN50 (50 mm) individual pump flanges, rated for system water temperatures from 0°C to 40°C.
Mechanical stability is delivered through a rigid structural steel support frame. Integrated elastomeric machine mounts isolate rotational vibration, protecting connected manifold pipework from mechanical stress while a factory-mounted 18L diaphragm tank buffers line draw. Assembled and hydrostatically tested to Australasian building plumbing standards, the package is supported by nationwide Davey service agents and spare parts availability.
FEATURES
- Dual variable speed inverter drives with automatic duty-assist and cyclical lead-lag alternation
- Maximum vertical shut-off delivery head up to 112 metres
- Cartridge silicon carbide, carbon, and EPDM mechanical seals rated to PN25 (16 bar)
- Integrated 18L 16bar flow-through diaphragm pressure vessel to buffer system pressure
- Permissible system clean liquid operating temperature range from 0°C to 40°C
- Factory-plumbed suction and delivery manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports and DN50 (50 mm) pump flanges
- Combined parallel peak water delivery flow up to 766 L/min (46 m³/h) or 383 L/min per pump
- Twin 7.5 kW three-phase IE3 high-efficiency TEFC electric motors
- Three-phase 415V, 50 Hz electrical operation drawing 2 x 14.6 Amps full load current
- AISI 304 stainless steel impellers and stage chambers with 316L stainless steel shafts
- Dual parallel Davey VM15-8 vertical multistage pumps featuring 8 hydraulic stages per pump
- Backed by Davey 2-year pump wet end warranty and 2-year variable speed inverter drive warranty against manufacturing defects
What's Included
- Davey Monsoon Light Packaged Twin Pump Booster Skid
- 2 x Davey VM15-8 Vertical Multistage Pumps with Variable Speed Inverter Drives
- 1 x Factory-Mounted 18L 16bar Diaphragm Pressure Tank
- Suction and Delivery Manifolds with DN80 (80 mm) AS2129 Table E flanged manifold ports
- Individual Suction and Discharge Isolation Ball Valves and Non-Return Check Valves
- Dual Pressure Transducers and Visual System Pressure Gauge
- Rigid Structural Steel Mounting Baseplate with Vibration Isolation Mounts
- Manufacturer Installation and Operating Instructions
SPECIFICATIONS
| Max Flow | 766 L/Min |
| Max Head | 112 m |
| Power | 2 x 7.5 kW / 415v |
| Rated Current | 2 x 14.6 Amps |
| Suitable For | Multi-Tier Commercial Building Header Boosting |
| Body Material | 304 Stainless Steel |
| Liquid Temperature | -15°C to +120°C |
| Inlet Size | 80 mm |
| Outlet Size | 80 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What maximum delivery head can this multistage wet end achieve under closed valve conditions?
Operating pressure envelope on the Davey Monsoon Light VM15-8 Three Phase 7.5kW Variable Speed Twin Pump Booster Set with 18L Tank attains a maximum static shut-off head of 112 metres across 8 stages per pump with a PN25 or 16 bar pressure rating, handling system water from 0 deg C to 40 deg C.
Which construction materials, hydraulic connection sizes, and pressure vessel are standard?
Constructed with 304 stainless steel stages and impellers on a structural steel skid, the 2MLV15-8M3-18HP incorporates silicon carbide mechanical seals, DN80 80 mm AS2129 Table E flanged manifold ports with DN50 50 mm pump flanges, and an 18L 16bar pressure tank.
Which warranty terms cover the pump wet end and variable frequency inverter?
Factory warranty provisions for the 2MLV-15-8M3-18HP cover both the hydraulic pump wet ends and the variable speed drives for 2 years against manufacturing defects.
What maximum fluid delivery volume can this dual multistage pump package maintain?
Rated for combined volumetric throughput, the 2MLV 15 8M3 18HP yields up to 766 L/min or 46 m3/h with twin pumps active, each delivering up to 383 L/min or 23 m3/h to hold constant line pressure.
How are electrical propulsion and variable speed automation configured for this unit?
Mains supply parameters for the VM15-8 (2MLV15-8M3-18HP) specify Three Phase 415V at 50 Hz to operate twin 7.5 kW motors drawing 2 x 14.6 Amps regulated by integrated dual inverter electronics.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us