Davey Monsoon Light VM3-17 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank
SKU: 2MLV3-17M3-18HP

Davey Monsoon Light VM3-17 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank

$0.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Davey
24 Months
Peace of Mind
Max Flow
146 L/Min
Max Head
126 m
Power
2 x 2.2 kW / 415v
Ideal Use
Commercial High-Head Washdown & Boiler Feed

Product Overview

Hotel resorts and hospitality precincts manage peak guest shower demand using the Davey Monsoon Light dual vertical multistage booster package. Configured with dual parallel vertical multistage pumps on a unified skid, the assembly balances incoming water supply across expanding multi-zone networks. Automatic duty-assist and lead-lag alternation stage both pumps dynamically to prevent pressure dropouts across elevated plumbing risers.

From a hydraulic standpoint, the dual multi-stage wet ends supply combined peak flow up to 146 L/min (8.8 m³/h), with 73 L/min each. Across vertical distribution risers, each 17-stage Davey VM3-17 hydraulic stack generates up to 126 metres of maximum shut-off head. Internal impellers, stage diffusers, and outer sleeves are constructed from AISI 304 stainless steel with a 316L stainless steel pump shaft to preserve clean water quality. Cartridge silicon carbide, carbon, and EPDM mechanical seals pair with PN25 (16 bar) rated wet ends for high-pressure containment.

The mechanical package incorporates dual efficient induction motors built for multi-storey building duties. Speed regulation is governed by dual variable frequency drives operating in synchronized lead-lag and parallel cascade staging to hold constant line pressure. The three-phase electrical system connects to a 415V supply at 50 Hz, powering twin 2.2 kW TEFC motors with a rated current draw of 2 x 4.3 Amps. Factory-plumbed stainless steel headers incorporate 2" BSP (50 mm) threaded manifold ports alongside DN25 (25 mm) individual pump flanges, rated for system water temperatures from 0°C to 40°C.

Factory construction includes a unified, vibration-damped structural steel mounting skid. Integrated elastomeric machine mounts isolate rotational vibration, protecting connected manifold pipework from mechanical stress while a factory-mounted 18L diaphragm tank buffers line draw. Assembled and hydrostatically tested to Australasian building plumbing standards, the package is supported by nationwide Davey service agents and spare parts availability.

FEATURES

  • Twin 2.2 kW three-phase IE3 high-efficiency TEFC electric motors
  • Maximum vertical shut-off delivery head up to 126 metres
  • Dual parallel Davey VM3-17 vertical multistage pumps featuring 17 hydraulic stages per pump
  • Factory-plumbed suction and delivery manifolds with 2" BSP (50 mm) threaded manifold ports and DN25 (25 mm) pump flanges
  • Integrated 18L 16bar flow-through diaphragm pressure vessel to buffer system pressure
  • Three-phase 415V, 50 Hz electrical operation drawing 2 x 4.3 Amps full load current
  • Combined parallel peak water delivery flow up to 146 L/min (8.8 m³/h) or 73 L/min per pump
  • Cartridge silicon carbide, carbon, and EPDM mechanical seals rated to PN25 (16 bar)
  • Dual variable speed inverter drives with automatic duty-assist and cyclical lead-lag alternation
  • AISI 304 stainless steel impellers and stage chambers with 316L stainless steel shafts
  • Permissible system clean liquid operating temperature range from 0°C to 40°C
  • Backed by Davey 2-year pump wet end warranty and 2-year variable speed inverter drive warranty against manufacturing defects

What's Included

  • Davey Monsoon Light Packaged Twin Pump Booster Skid
  • 2 x Davey VM3-17 Vertical Multistage Pumps with Variable Speed Inverter Drives
  • 1 x Factory-Mounted 18L 16bar Diaphragm Pressure Tank
  • Suction and Delivery Manifolds with 2" BSP (50 mm) threaded manifold ports
  • Individual Suction and Discharge Isolation Ball Valves and Non-Return Check Valves
  • Dual Pressure Transducers and Visual System Pressure Gauge
  • Rigid Structural Steel Mounting Baseplate with Vibration Isolation Mounts
  • Manufacturer Installation and Operating Instructions
SPECIFICATIONS
Max Flow146 L/Min
Max Head126 m
Power2 x 2.2 kW / 415v
Rated Current2 x 4.3 Amps
Suitable ForCommercial High-Head Washdown & Boiler Feed
Body Material304 Stainless Steel
Liquid Temperature-15°C to +120°C
Inlet Size50 mm
Outlet Size50 mm
Warranty24 Months
Documents
Specification Datasheet Download
VM Series Pumps Datasheet Download
Monsoon MLV IQ2 Brochure Download
Installation Instructions Download

Timber processing mills commission the 2MLV3-17M3-18HP dual booster unit to feed misting headers on log debarking lines and dust suppression hoods. Twin vertical multistage pumps develop high static head to atomize water effectively, controlling airborne sawdust across indoor milling halls.

  • Feeding misting headers
  • Controlling airborne dust
  • Atomizing wash water
  • Supplying debarking lines

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
VM Series Pumps Datasheet
Download
Monsoon MLV IQ2 Brochure
Download
Installation Instructions
Download
What internal wetted metallurgy, manifold port sizes, and mounting baseplate are fitted?

Wetted casing metallurgy on the Davey Monsoon Light VM3-17 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank features 304 stainless steel impellers and chambers, 316L stainless shafts, 2" BSP 50 mm threaded manifold ports with DN25 25 mm pump ports, an 18L 16bar diaphragm vessel, and a rigid mounting skid.

How is factory warranty coverage structured between the pump end and inverter drive?

Official Davey manufacturer warranty coverage protects the 2MLV3-17M3-18HP, providing 2 years of coverage on both the pump wet ends and the variable speed inverter drives against manufacturing defects.

What volumetric fluid throughput rate does this dual booster assembly supply?

Operating in parallel duty-assist mode, the 2MLV-3-17M3-18HP reaches up to 146 L/min or 8.8 m3/h across both pumps, with each individual pump providing up to 73 L/min or 4.4 m3/h.

Which electrical power mains and frequency converters operate this twin booster set?

Configured for Three Phase 415V, 50 Hz power networks, the 2MLV 3 17M3 18HP pairs two 2.2 kW electric motors drawing 2 x 4.3 Amps with dual frequency drives for synchronized constant pressure regulation.

To what vertical elevation height can this booster system drive clean water?

Hydraulic pressure boundaries enable the VM3-17 (2MLV3-17M3-18HP) to attain up to 126 metres of static lift across 17 stages and withstand PN25 or 16 bar pressure at system temperatures from 0 deg C to 40 deg C.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed