Roll over image to zoom
SKU: 2MLV5-14M3-18HP
Davey Monsoon Light VM5-14 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank
Australia-Wide
(08) 9240 2992
Official Davey
Peace of Mind
Product Overview
Logistics distribution centres and freight warehouse complexes maintain steady water reticulation with the Davey Monsoon Light dual pump booster set. Configured with dual parallel vertical multistage pumps on a unified skid, the assembly balances incoming water supply across expanding multi-zone networks. Automatic duty-assist and lead-lag alternation stage both pumps dynamically to prevent pressure dropouts across elevated plumbing risers.
Calibrated for high-flow duties, the dual package outputs peak clean water volume up to 284 L/min (17 m³/h), with 142 L/min per pump. Across vertical distribution risers, each 14-stage Davey VM5-14 hydraulic stack generates up to 111 metres of maximum shut-off head. Internal impellers, stage diffusers, and outer sleeves are constructed from AISI 304 stainless steel with a 316L stainless steel pump shaft to preserve clean water quality. Cartridge silicon carbide, carbon, and EPDM mechanical seals pair with PN25 (16 bar) rated wet ends for high-pressure containment.
Propulsion is handled by dual energy-efficient electric motors operating at rated synchronous speed. Speed regulation is governed by dual variable frequency drives operating in synchronized lead-lag and parallel cascade staging to hold constant line pressure. The three-phase electrical system connects to a 415V supply at 50 Hz, powering twin 2.2 kW TEFC motors with a rated current draw of 2 x 4.3 Amps. Factory-plumbed stainless steel headers incorporate 2" BSP (50 mm) threaded manifold ports alongside DN32 (32 mm) individual pump flanges, rated for system water temperatures from 0°C to 40°C.
The twin booster system is fully plumbed and wired onto a unified common structural base. Integrated elastomeric machine mounts isolate rotational vibration, protecting connected manifold pipework from mechanical stress while a factory-mounted 18L diaphragm tank buffers line draw. Assembled and hydrostatically tested to Australasian building plumbing standards, the package is supported by nationwide Davey service agents and spare parts availability.
FEATURES
- Integrated 18L 16bar flow-through diaphragm pressure vessel to buffer system pressure
- AISI 304 stainless steel impellers and stage chambers with 316L stainless steel shafts
- Dual variable speed inverter drives with automatic duty-assist and cyclical lead-lag alternation
- Twin 2.2 kW three-phase IE3 high-efficiency TEFC electric motors
- Dual parallel Davey VM5-14 vertical multistage pumps featuring 14 hydraulic stages per pump
- Factory-plumbed suction and delivery manifolds with 2" BSP (50 mm) threaded manifold ports and DN32 (32 mm) pump flanges
- Cartridge silicon carbide, carbon, and EPDM mechanical seals rated to PN25 (16 bar)
- Maximum vertical shut-off delivery head up to 111 metres
- Combined parallel peak water delivery flow up to 284 L/min (17 m³/h) or 142 L/min per pump
- Three-phase 415V, 50 Hz electrical operation drawing 2 x 4.3 Amps full load current
- Permissible system clean liquid operating temperature range from 0°C to 40°C
- Backed by Davey 2-year pump wet end warranty and 2-year variable speed inverter drive warranty against manufacturing defects
What's Included
- Davey Monsoon Light Packaged Twin Pump Booster Skid
- 2 x Davey VM5-14 Vertical Multistage Pumps with Variable Speed Inverter Drives
- 1 x Factory-Mounted 18L 16bar Diaphragm Pressure Tank
- Suction and Delivery Manifolds with 2" BSP (50 mm) threaded manifold ports
- Individual Suction and Discharge Isolation Ball Valves and Non-Return Check Valves
- Dual Pressure Transducers and Visual System Pressure Gauge
- Rigid Structural Steel Mounting Baseplate with Vibration Isolation Mounts
- Manufacturer Installation and Operating Instructions
SPECIFICATIONS
| Max Flow | 284 L/Min |
| Max Head | 111 m |
| Power | 2 x 2.2 kW / 415v |
| Rated Current | 2 x 4.3 Amps |
| Suitable For | Hotel & Institutional Sanitary Riser Boosting |
| Body Material | 304 Stainless Steel |
| Liquid Temperature | -15°C to +120°C |
| Inlet Size | 50 mm |
| Outlet Size | 50 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
How do the integrated variable speed drives regulate electric motor speed on this skid?
Electronic speed control on the Davey Monsoon Light VM5-14 Three Phase 2.2kW Variable Speed Twin Pump Booster Set with 18L Tank utilizes Three Phase 415V electrical supply at 50 Hz, powering twin 2.2 kW IE3 motors drawing 2 x 4.3 Amps under dual variable speed inverter control.
What shut off head elevation and maximum casing pressure rating apply to this unit?
Developing up to 111 metres of maximum static head across 14 stages per pump, the 2MLV5-14M3-18HP sustains PN25 or 16 bar working pressure across liquid temperatures from 0 deg C to 40 deg C.
Which construction materials, hydraulic connection sizes, and pressure vessel are standard?
Wetted construction on the 2MLV-5-14M3-18HP combines 304 stainless steel hydraulic components and 316L shafts seated on a mounting skid, linked by 2" BSP 50 mm threaded manifold ports, DN32 32 mm pump ports, and an 18L 16bar expansion tank.
Which warranty terms cover the pump wet end and variable frequency inverter?
Warranty protection supporting the 2MLV 5 14M3 18HP encompasses official Davey coverage including 2 years on both the pump wet ends and the variable speed drive units against manufacturing defects.
What maximum fluid delivery volume can this dual multistage pump package maintain?
To satisfy heavy site water demand, the VM5-14 (2MLV5-14M3-18HP) provides up to 284 L/min or 17 m3/h across dual parallel pumps, or up to 142 L/min per pump under variable speed coordination.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us