Grundfos NB 32-125/130 Cast Iron 2.2 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93207151

Grundfos NB 32-125/130 Cast Iron 2.2 kW End Suction Centrifugal Pump with Closed Impeller

$3,173.39 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
419 L/Min
Max Head
18.39 m
Power
2.2 kW / 415v
Ideal Use
District Heating & Cooling Networks

Product Overview

Constructed for fixed foundation mounting in mechanical rooms, the NB 32-125/130 single-stage end-suction pump connects via DN 50 suction and DN 32 discharge ports. A 2.2 kW electric motor provides mechanical power for continuous water circulation across building service headers.

Fluid output parameters show a rated throughput of 419 L/Min and a maximum head limit of 18.39 m. Electrocoating treatment on the cast iron casing limits rust in hydronic loops. The internal rotor holds a stainless steel impeller with bronze wear rings. Unit physical weight is 48 kg.

Operating on a 415 V three-phase power supply, the NB 32-125/130 electric motor yields 2.2 kW output power with a current draw of 7.56 Amps. Media temperature capabilities span from -25°C to 120°C under continuous line pressures up to 16 bar. Flanged ports feature DN 50 suction and DN 32 discharge sizing.

Winding insulation on the NB 32-125/130 motor complies with Class F standards within an IP55 dust and spray resistant motor housing equipped with PTC thermistors. Service procedures benefit from back-pull-out construction, permitting internal rotor disassembly without disconnecting main system pipework headers.

Features

  • Back pull-out design allows complete rotating assembly removal including motor, coupling and impeller without disturbing pump housing or connected pipework.
  • EN733 and ISO2858 dimensional compliance ensures interchangeability with other standard end-suction pumps across commercial and industrial installations.
  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).
  • Integrally cast suction and discharge ports with dedicated vent and drain ports provide direct connection points without additional fittings.
  • No baseplate or grouting required to maintain correct shaft alignment and vibration levels within Hydraulic Institute standards.
  • Cataphoretic electrocoating on cast iron internal surfaces provides barrier protection against oxidative corrosion in hydronic circulation loops.
  • Close-coupled configuration eliminates coupling alignment procedures and reduces overall installation footprint compared to long-coupled alternatives.

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow419 L/Min
Max Head18.39 m
Power2.2 kW / 415v
Rated Current7.81 Amps
Suitable ForDistrict Heating & Cooling Networks
Body MaterialCast Iron
Liquid Temperature'-25°C to 120°C
Inlet Size50 mm
Outlet Size32 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Condenser water transfer circuits connecting cooling towers incorporate The Grundfos NB 32-125/130 to sustain steady fluid displacement. Heavy-duty bearing assemblies support smooth motor shaft rotation, providing dependable service under heavy thermal loads.

  • Condenser Water Loops
  • Cooling Towers
  • Cooling Skids
  • Chiller Plant Rooms

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
How high can this pump push fluid through discharge risers?

Vertical elevation capability on the Grundfos NB 32-125/130 reaches a maximum dynamic head of approximately 18.39 m under rated conditions.

What is the maximum flow capacity of this pump per minute?

Fluid evacuation capacity for the NB 32-125/130 peaks at approximately 419 L/Min, providing dependable high-volume drainage.

What materials are used to construct the pump casing and impeller?

Manufactured with quality materials, the NB-32-125-130 incorporates high-grade alloy for dependable longevity and resistance to fluid erosion.

What voltage supply and motor power does this pump need?

Under full load conditions, the motor in the NB 32 125 130 delivers 2.2 kW on a 415 V three-phase line drawing 7.81 Amps.

What fluid temperature limits and immersion depths are rated for this unit?

Tested for thermal durability, the NB/32/125/130 tolerates working fluid temperatures -25°C to 120°C.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed