Grundfos NB 40-125/130 Cast Iron 0.37 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209239

Grundfos NB 40-125/130 Cast Iron 0.37 kW End Suction Centrifugal Pump with Closed Impeller

$3,019.12 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
363 L/Min
Max Head
3 m
Power
0.37 kW / 415v
Ideal Use
Commercial Building Services HVAC

Product Overview

Closed-loop circulation duties across heating and chilled water risers use the Grundfos NB 40-125/130 end-suction pump. The unit couples a 0.37 kW drive motor to an axial DN 65 inlet nozzle and a radial DN 40 discharge connection.

Flow delivery reaches 363 L/Min under rated duty conditions with a maximum developed head of 3.899 m. Volute casing construction features EN-GJL-250 cast iron with cataphoretic electrocoating, paired with a stainless steel impeller and BQQE shaft seal. Product net weight equals 32 kg.

Connected to a 415 V three-phase power feed, the drive draws 0.99 Amps while delivering 0.37 kW motor power. Operating limits support liquid temperatures from -25°C to 120°C and maximum system pressures of 16 bar. Flanged pipework attaches via DN 65 inlet and DN 40 outlet ports.

Motor ingress protection satisfies IP55 standards with Class F temperature insulation. Standard motor installation requires external electrical overload protection. The back-pull-out design allows complete drive and rotating assembly extraction while leaving the casing secured to distribution pipework.

Features

  • Cast iron volute casing with integral mounting feet absorbs hydraulic forces and pipework stresses.
  • Replaceable wear rings retain correct internal hydraulic clearances over long operating periods.
  • Solid stub shaft configuration supported by deep groove ball bearings absorbs axial thrust loads.
  • Standardized EN1092-2 PN16 flange dimensions match standard commercial and district pipe manifolds.
  • High-efficiency IEC electric drive motor rated for S1 continuous operation in ambient conditions up to 40°C.
  • Back-pull-out construction allows drive and impeller removal without disconnecting suction or discharge lines.
  • Precision balanced rotor and runner assemblies minimize operating vibration across all pump speeds.
SPECIFICATIONS
Max Flow363 L/Min
Max Head3 m
Power0.37 kW / 415v
Rated Current0.99 Amps
Suitable ForCommercial Building Services HVAC
Body MaterialCast Iron
Liquid Temperature-25°C to 120°C
Inlet Size65 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Airport terminal air conditioning systems utilize the Grundfos NB 40-125/130 to circulate chilled liquid across extensive passenger concourses. Regulated mass flow distributes cooling media through distributed fan coil loops during heavy flight arrival periods.

  • Airport Terminals
  • Fan Coil Loops
  • Concourse Cooling
  • Chilled Distribution

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
How is the pump body constructed to withstand long operational wear?

Cast iron construction on the Grundfos NB 40-125/130 utilizes an electrocoated EN-GJL-250 casing and a precision stainless steel impeller.

Can service technicians extract the impeller without disconnecting the volute from pipework?

Routine plant servicing is simplified on the NB 40-125/130 by its back-pull-out layout, allowing drive extraction without dismantling pipework.

How much fluid volume and pressure elevation can this unit displace?

The NB-40-125-130 provides up to 363 L/Min in fluid flow and 3.899 m in dynamic head, depending on system pressure demands.

What electrical feed and full-load current are needed for this motor?

Driven across a 415 V three-phase supply, the NB 40 125 130 features a 0.37 kW motor drawing 0.99 Amps with an IP55 enclosure.

What shaft sealing mechanism and wear protection protect this pump casing against mechanical fluid loss?

Fluid containment in the NB/40/125/130 is maintained by a BQQE mechanical shaft seal, supported by replaceable wear rings that preserve hydraulic clearances.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed