Grundfos NB 40-160/134 Cast Iron 0.37 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209253

Grundfos NB 40-160/134 Cast Iron 0.37 kW End Suction Centrifugal Pump with Closed Impeller

$3,107.01 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
245 L/Min
Max Head
4 m
Power
0.37 kW / 415v
Ideal Use
Cooling Tower Hydronic Systems

Product Overview

Secondary chilled water circuits and plant distribution skids deploy the Grundfos NB 40-160/134 centrifugal pump. Driven by an electric 0.37 kW motor assembly, the pump incorporates an axial DN 65 suction port and a radial DN 40 discharge connection.

Operational fluid output delivers 245 L/Min rated capacity across a maximum head span of 4.697 m. The pump housing is cast in EN-GJL-250 iron with cataphoretic electrocoating. Fluid displacement is driven by a stainless steel impeller and a BQQE mechanical shaft seal. Net product weight measures 33 kg.

Motor operation on a 415 V three-phase feed requires 0.99 Amps rated current for 0.37 kW shaft output. Operational limits permit media temperatures from -25°C to 120°C under working pressures up to 16 bar. Flanged pipe connections measure DN 65 on the inlet and DN 40 on the outlet.

The drive assembly provides an IP55 enclosure rating and Class F thermal insulation. Standard IEC electric drive design requires external motor overload protection. The back-pull-out structural layout permits complete motor and rotating assembly extraction without disconnecting piping headers.

Features

  • Solid stub shaft supported by sealed ball bearings carries axial and radial loads.
  • Standard PN16 flanged port interfaces align with EN1092-2 heating and cooling headers.
  • Totally enclosed fan cooled IEC motor rated for S1 duty cycles in ambient environments up to 40°C.
  • Service-friendly back-pull-out layout enables rotating element servicing without removing pipework.
  • Balanced impeller geometry and shaft construction reduce operational vibration throughout duty range.
  • Volute casing design incorporates integral base feet for direct mounting to concrete plinths.
  • Internal wear rings retain hydraulic clearance tolerances throughout long service cycles.
SPECIFICATIONS
Max Flow245 L/Min
Max Head4 m
Power0.37 kW / 415v
Rated Current0.99 Amps
Suitable ForCooling Tower Hydronic Systems
Body MaterialCast Iron
Liquid Temperature-25°C to 120°C
Inlet Size65 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Bulk liquid blending vessels in food packaging facilities deploy the Grundfos NB 40-160/134 for steady ingredient wash circulation. Sanitary fluid transfer propels wash liquids through clean-in-place rinse circuits between production runs.

  • Wash Circulation
  • Rinse Circuits
  • Food Facilities
  • Packaging Plants

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
What operating temperature limits and line pressure ratings are supported?

Temperature boundaries on the Grundfos NB 40-160/134 permit pumped media from -25°C to 120°C under working pressure limits up to 16 bar.

How much water delivery and hydraulic lift can this unit achieve?

Operating capacity on the NB 40-160/134 reaches up to 245 L/Min in liquid flow and 4.697 m in dynamic head across duty cycles.

What suction and discharge flange dimensions connect to mechanical plant pipework?

Standard PN16 flanged connections on the NB-40-160-134 include an axial 65 mm suction intake and a radial 40 mm discharge port.

Is it possible to inspect internal components without disturbing facility pipe connections?

Routine plant servicing is simplified on the NB 40 160 134 by its back-pull-out layout, allowing drive extraction without dismantling pipework.

Which electrical supply standards govern this heavy pump motor?

Operating on a 415 V three-phase supply, the NB/40/160/134 utilizes a 0.37 kW motor drawing 0.99 Amps with IP55 weatherproof protection.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed