Grundfos NB 40-315/318 Cast Iron 37 kW End Suction Centrifugal Pump with Closed Impeller
SKU: 93209287

Grundfos NB 40-315/318 Cast Iron 37 kW End Suction Centrifugal Pump with Closed Impeller

$16,107.25 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Grundfos
24 Months
Peace of Mind
Max Flow
868 L/Min
Max Head
100.1 m
Power
37 kW / 415v
Ideal Use
High-Capacity Plant Room Pumping

Product Overview

Constructed for fixed foundation mounting in mechanical rooms, the NB 40-315/318 single-stage end-suction pump connects via DN 65 suction and DN 40 discharge ports. A 37 kW electric motor provides mechanical power for continuous water circulation across building service headers.

Fluid output parameters show a rated throughput of approx. 868 L/Min and a maximum head limit of approx. 100.1 m. Electrocoating treatment on the cast iron casing limits rust in hydronic loops. The internal rotor holds a stainless steel impeller with bronze wear rings. Unit physical weight is 330 kg.

Operating on a 415 V three-phase power supply, the NB 40-315/318 electric motor yields 37 kW output power with a current draw of 68.1 Amps. Media temperature capabilities span from -25°C to 120°C under continuous line pressures up to 16 bar. Flanged ports feature DN 65 suction and DN 40 discharge sizing.

Winding insulation on the NB 40-315/318 motor complies with Class F standards within an IP55 dust and spray resistant motor housing equipped with PTC thermistors. Service procedures benefit from back-pull-out construction, permitting internal rotor disassembly without disconnecting main system pipework headers.

Features

  • All stainless steel shaft construction provides improved corrosion resistance compared to carbon steel alternatives in wetted service areas.
  • Mechanical shaft seal can be replaced without removing the impeller, system piping, pump volute casing or drive motor from the installation.
  • Housing, impeller and wear ring use dissimilar material pairings to prevent galling and ensure no sticking elements during extended standby periods.
  • High-efficiency motor selection is configured to match the specific power supply characteristics, pumping environment and liquid properties of each installation.
  • Back pull-out design allows complete rotating assembly removal including motor, coupling and impeller without disturbing pump housing or connected pipework.
  • EN733 and ISO2858 dimensional compliance ensures interchangeability with other standard end-suction pumps across commercial and industrial installations.
  • ATEX Zone 1, 2, 21 or 22 certification available for operation in potentially explosive atmospheres (except E-model variants).

IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.

SPECIFICATIONS
Max Flow868 L/Min
Max Head100.1 m
Power37 kW / 415v
Rated Current68.1 Amps
Suitable ForHigh-Capacity Plant Room Pumping
Body MaterialCast Iron
Liquid Temperature-25°C to 120°C
Inlet Size65 mm
Outlet Size40 mm
Warranty24 Months
Documents
Product Brochure Download
Specification Datasheet Download
Operating Manual Download
Data Booklet Download
Service Instructions Download

Transmission pumping stations in major district networks rely on The Grundfos NB 40-315/318 for vertical fluid propulsion. Robust electric power delivers steady pressure through long-distance district mains, maintaining thermal distribution across distant sectors.

  • Transmission Pumping Stations
  • District Heating Mains
  • Long-Distance Mains
  • Central Utilities

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Product Brochure
Download
Specification Datasheet
Download
Operating Manual
Download
Data Booklet
Download
Service Instructions
Download
How much fluid can this pump evacuate during peak demand?

Discharge throughput on the Grundfos NB 40-315/318 reaches a maximum flow rate of approximately 868 L/Min under standard operating conditions.

What materials make this pump durable against corrosion and wear?

Wetted components on the NB 40-315/318 are crafted from high-grade EN-GJL-250 to maintain physical integrity and resist abrasive wear.

How much electricity and current does this pump draw under load?

Electrical power for the NB-40-315-318 requires a 415 V three-phase connection, driving an efficient 37 kW motor that draws 68.1 Amps.

How is the pump casing constructed to resist mechanical and fluid wear?

Structural defense on the NB 40 315 318 is provided by a rugged high-grade alloy casing designed to withstand heavy mechanical stress.

What total dynamic head can this pump overcome in vertical pipework?

Dynamic lift generated by the NB/40/315/318 reaches a maximum elevation head of approximately approx. 100.1 m across discharge lines.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us