Highlighting extended continuous circulation capacities, this pump is natively designed for handling wastewater, process water, unscreened raw sewage, municipal, domestic and industrial applications. The S2.110.200.1150.4.70M.C.416.G.N.D.513GPA unit is strictly suitable for submerged physical installation setups utilizing the active 96641489 auto coupling interface connection base to establish deep continuous fluid transfer capabilities. The cooling jacket provides superior thermal management in submerged and dry installations.
Constructed from solid Cast iron EN 1561 EN-GJL-250, the physical outer housing surrounds central dynamic components. The 2-channel impeller, measuring exactly 417 mm in overall diameter, effectively processes suspended physical solids up to 110 mm in size. The internal core motor casing is manufactured from Cast iron EN 1561 EN-GJL-250. The mechanical unit weighs 1230 kg and operates strictly in Newtonian liquids up to 40°C.
The 115 kW electrical motor works on a three-phase 415v continuous power supply, operating with a designated steady continuous current of 203 Amps. The heavy industrial unit achieves a maximum head of 66 meters and a maximum flow volume of 20160 L/Min running directly through a DN 200 mm discharge outlet. The continuous operating power input P1 is specified directly at 122 kW, running alongside an electrical starting current rated exactly at 1380 Amps.
System thermal safety is strictly provided by Class F internal motor insulation combined with a rated IP68 physical enclosure parameter. The extensive hardware fully supports continuous vertical physical installation depths reaching up to 20 meters. Primary SIC mechanical seals and secondary SIC-CARBON shaft seals precisely provide constant internal fluid containment. The operational architecture incorporates a 4-pole motor matched with a Y/D starting mechanism. The cooling jacket enables flexible installation options.
Features
- Features lifting height class M standard dimension specification for operation
- Integrates internal physical moisture sensors explicitly for continuous fluid system evaluation
- Includes core hardware thermistors designed for active thermal response observations
- Utilizes S1BN8-F specification active power cable measuring precisely 15 meters
- Operates actively with a continuous mechanical baseline speed of 1475 revolutions per minute
- Accommodates a standard maximum of 15 electrical motor starts per operational hour
- Cooling jacket enables submerged or dry installation without motor cooling
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 20160 L/Min |
| Max Head | 66 m |
| Power | 115 kW / 415v |
| Rated Current | 203 Amps |
| Suitable For | Municipal Sewage |
| Body Material | Cast Iron |
| Liquid Temperature | Maximum 40°C |
| Outlet Size | 200 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What peak dynamic elevation does this pump develop?
Fluid elevation through vertical risers reaches up to 4.70M with the Grundfos S2.110.200.1150.4.70M.C.416 under standard duty points.
What total dynamic head can this pump overcome in vertical pipework?
Vertical elevation capability on the S2.110.200.1150.4.70M.C.416 reaches a maximum dynamic head of approximately 4.70M under rated conditions.
What is the maximum water flow rate and head pressure of this pump?
Rated for dependable performance, the S2-110-200-1150-4-70M-C-416 provides up to 20160 L/Min in flow and up to 70M in head, depending on operating conditions.
How high can this pump push fluid through discharge risers?
Pumping performance for the S2 110 200 1150 4 70M C 416 provides up to 70M of vertical dynamic lift, depending on system friction and line sizing.
What are the power requirements and running amperage for this pump?
Under full load conditions, the motor in the S2/110/200/1150/4/70M/C/416 delivers 115 kW on a 415 V three-phase line drawing 203 A.