Roll over image to zoom
SKU: 96087638
Grundfos TP 65-240/4 Cast Iron 4kW Three Phase Inline Centrifugal Pump with Bronze Impeller
Australia-Wide
(08) 9240 2992
Official Grundfos
Peace of Mind
Product Overview
Handling operating liquid temperatures from -25°C to 120°C, the TP 65-240/4 inline centrifugal pump is rated for maximum working pressures up to 16 bar. The system incorporates a maintenance-free BQQE mechanical shaft seal to contain circulating media across heating and cooling circuits.
During active pumping duty, the unit delivers 774 L/Min rated flow alongside 24 m maximum head output. The cast iron casing body receives electrocoating to protect internal surfaces. Liquid containment relies on a BQQE shaft seal and a bronze impeller. Physical net weight is 86.5 kg.
A 415 V three-phase electrical supply delivers power to the 4 kW motor, drawing 7.9 Amps rated current. Operational liquid limits handle fluid temperatures spanning -25°C to 120°C under working pressures to 16 bar. Opposite DN 65 flanged connections simplify pipe integration.
Internal motor windings are protected by Class F insulation, PTC thermistors, and an IP55 dust-tight enclosure rating. Top-pull-out service construction simplifies inspection by allowing drive removal without unbolting the pump volute from system headers.
Features
- High-head variant achieving 774 L/Min rated flow and 24 m maximum head output.
- 4 kW three-phase motor rated at 7.9 Amps for demanding hydronic circulation.
- EN-GJL-250 cast iron volute casing with cataphoresis electrocoating finish.
- DN 65 flanged connection ports for medium-bore piping network integration.
- Bronze impeller and BQQE mechanical shaft seal for maintenance-free clean water duty.
- IP55 motor enclosure with Class F insulation and internal PTC thermistor monitoring.
- Top-pull-out design allowing impeller and drive extraction without system pipework removal.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 774 L/Min |
| Max Head | 24 m |
| Power | 4 kW / 415v |
| Rated Current | 7.9 Amps |
| Suitable For | District Heating Circulation |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 65 mm |
| Outlet Size | 65 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What kind of power supply does this pump require to run?
It operates on 415 V three-phase power, with the Grundfos TP 65-240/4 utilizing a durable 4 kW motor rated at 7.9 Amps.
What water temperature range and installation depth are supported?
Thermal ratings for the TP 65-240/4 accommodate working liquid temperatures -25°C to 120°C under standard operating pressure.
What maximum vertical water column can this pump maintain?
Pumping performance for the TP-65-240-4 provides up to 24 m of vertical dynamic lift, depending on system friction and line sizing.
What discharge flow rate does this pump maintain during peak operation?
Moving liquid through the system, the TP 65 240 4 maintains an operational throughput of up to 774 L/Min during peak demand.
Is the pump body built to withstand harsh and corrosive liquids?
Built with a resilient EN-GJL-250 body, the TP/65/240/4 maintains material durability against fluid abrasion and wear.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us