With a rated flow capacity of 1032 L/Min and a maximum head limit of 21 m, the TP 80-210/2 inline centrifugal pump meets fluid transfer requirements in commercial buildings. A 4 kW motor provides the necessary mechanical drive power for continuous water movement.
Constructed with an EN-GJL-250 cast iron casing, the housing body features cataphoresis electrocoating surface treatment for internal corrosion protection. The internal hydraulic assembly contains a precision bronze impeller fitted with bronze wear rings and a maintenance-free mechanical shaft seal. Net product weight measures 78.3 kg for fixed mounting placement in mechanical plant rooms.
The motor operates on a 415 V three-phase supply rated at 7.9 Amps nominal operating current. Operating liquid temperatures span from -25°C to 120°C under maximum working pressures up to 16 bar. In-line opposite port geometry with DN 80 flanged connections enables mounting directly into straight pipework lines or onto foundation bases.
Motor protection features an IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistors. Top-pull-out structural design enables removal of the motor head and impeller assembly without dismantling the pump housing from connected system pipework lines during scheduled servicing routines.
Features
- In-line structural design with opposite suction and discharge ports for direct pipework line mounting.
- EN-GJL-250 cast iron pump casing with protective cataphoresis electrocoating surface treatment.
- Internal hydraulic rotor assembly incorporating a precision manufactured bronze impeller.
- Rated hydraulic output capacity achieving 21 m maximum head and 1032 L/Min flow rate.
- Standardized DN 80 flanged connection ports for commercial HVAC and heating installation.
- IP55 enclosure rating with Class F thermal insulation and integrated PTC thermistor motor protection.
- Top-pull-out mechanical layout allowing service access without removing volute casing from pipework lines.
IMPORTANT: Bulk freight charges apply. Please contact us for a freight quote before ordering.
SPECIFICATIONS
| Max Flow | 1032 L/Min |
| Max Head | 21 m |
| Power | 4 kW / 415v |
| Rated Current | 7.9 Amps |
| Suitable For | Heat recovery loops |
| Body Material | Cast Iron |
| Liquid Temperature | '-25°C to 120°C |
| Inlet Size | 80 mm |
| Outlet Size | 80 mm |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What fluid temperature limits and immersion depths are rated for this unit?
Operating comfortably across temperatures -25°C to 120°C, the Grundfos TP 80-210/2 supports diverse fluid circuits.
What peak dynamic elevation does this pump develop?
Under rated operating head, the TP 80-210/2 can lift water to a maximum dynamic head of approximately 21 m through vertical risers.
How much water volume can this unit move through the pipework?
Peak fluid displacement on the TP-80-210-2 delivers up to 1032 L/Min through a 80 mm connection connection under rated operating conditions.
How is the pump casing constructed to resist mechanical and fluid wear?
High-grade Cast Iron components in the TP 80 210 2 protect internal passages against corrosive fluid contact.
Does this pump run on standard household power or three-phase power?
It operates on 415v three-phase power, with the TP/80/210/2 utilizing a durable 4 kW motor rated at 7.9 Amps.