Product Overview
Handling intensive fluid transfer across industrial sites relies on the consistent performance of the Lowara 10HM08S30T assembly. This horizontal multistage configuration provides a stable solution for closed-loop process cooling, medium-scale water supply systems, and aggressive circulation tasks where pressure retention is critical. Suction and delivery connections are integrated at 40mm and 32mm respectively, ensuring direct compatibility with standard pipework.
Operational threshold limits are defined by a Max Head 89.4 m alongside a Max Flow 233 L/Min. The unit operates via a 3 kW / 415v motor, drawing 6.32 Amps during typical load conditions. This power density allows the pump to maintain system stability even when facing high-backpressure environments within municipal or manufacturing utility layouts.
Fluid dynamics are governed by a closed impeller arrangement specifically engineered for efficiency within the e-HM series architecture. The multi-stage design progressively increases pressure across the stages, utilizing precision-molded components to minimize internal slip and turbulence. This arrangement ensures that the delivery volume remains predictable even as total system resistance fluctuates during high-cycle demand periods.
Constructed with an AISI 304 stainless steel casing, the pump unit provides resilient protection against chemical degradation and mechanical wear. The TEFC air-cooled IE3 motor is rated at IP55 for external ingress protection, with the overall assembly capable of handling liquid temperatures ranging from -10°C to +120°C. Mounting is facilitated by a robust base plate that minimizes vibration transfer through the plumbing network.
Features:
- Integrated IE3 efficiency class motor for reduced electrical draw
- AISI 304 stainless steel wetted components for chemical compatibility
- Suitable for continuous duty in closed-loop circulation systems
- TEFC motor cooling system for sustained thermal management
- IP55 ingress protection rating against environmental dust and moisture
- Modular architecture facilitating simplified service and component replacement
SPECIFICATIONS
| Max Flow | 233 L/Min |
| Max Head | 89.4 m |
| Power | 3 kW / 415v |
| Rated Current | 6.32 Amps |
| Suitable For | Industrial Process and Cooling Systems |
| Body Material | AISI 304 Stainless Steel |
| Liquid Temperature | '-10°C to +120°C |
| Inlet Size | 40 mm |
| Outlet Size | 32 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
When discharging into plumbing lines, what peak flow rate and pipe connection sizing apply?
Delivering steady water volume, the 10HM08S30T produces a peak delivery flow of approximately 233 L/Min through Rp 1-1/2" (40 mm) suction and Rp 1-1/4" (32 mm) discharge.
What metallurgy and mechanical seal components safeguard this booster against particulate corrosion?
The metallurgy profile of the 10HM-08S-30T utilizes AISI 304 stainless steel pump casing, diffusers, and closed impellers, reinforced with mechanical face seals for corrosion resilience.
Across facility electrical lines, what supply voltage and motor power rating in kilowatts apply?
Connecting into service power of 380–415 V, 50 Hz, three-phase, the 10HM 08S 30T utilizes a 3 kW (4.0 HP) motor pulling 6.32 A.
How much internal pressure in bar and what fluid operating temperature range does this booster accommodate?
Robust casing strength enables the 10HM_08S_30T to sustain a maximum working pressure capability of 16 bar (PN 16) with fluid temperature limits from -10°C to +120°C.
Across multi-floor piping, what dynamic lift head applies to this commercial booster?
Lifting water across elevation gradients, the 10HM08S30T achieves a peak dynamic head of approximately 89.4 m.