Max Flow
73.3 L/Min
Max Head
14.6 m
Power
0.3 kW / 415v
Ideal Use
Cooling Systems

Product Overview

The Lowara 3HM02S03T provides efficient and reliable pumping performance. Suction-side fluid handling in small-scale industrial cooling loops relies on the precise, close-coupled orientation of this compact unit. It manages clean, non-aggressive fluids within diverse mechanical assemblies, ensuring steady circulation for systems requiring consistent flow dynamics. The configuration is specifically engineered for installations where space efficiency is as critical as long-term reliability in varying process environments.

Operational parameters are defined by a Max Head 14.6 m and a Max Flow 73.3 L/Min. This performance is generated by a 0.3 kW motor drawing 1.08 Amps, providing the necessary energy to maintain flow stability through 25 mm suction and delivery ports. The unit is calibrated to function effectively within these limits, sustaining hydraulic efficiency under standard operating conditions.

Hydraulic integrity is managed by a multistage arrangement composed of AISI 304 stainless steel components. Fluid enters and travels through the internal channels, directed by precise stage geometry that minimizes turbulence. This design promotes a smooth transition of energy into kinetic force, allowing the assembly to meet demanding circulation requirements with minimal mechanical deviation throughout the service cycle.

Housing the internals is a robust AISI 304 stainless steel body, offering corrosion resistance across its operational temperature range of -10°C to +120°C. The motor is protected by an IP55 rating, while the electric pump assembly itself adheres to IPX5 standards. Mounting is facilitated by a standard foot-base design, which integrates with the unit's 6 kg frame to ensure stability when bolted to structural framing or process skids.

Features:

  • TEFC 2-pole squirrel-cage motor configuration for consistent operation
  • Class 155 insulation to manage internal thermal loads
  • WRAS and ACS certification for compatibility with drinking water loops
  • Vibration-dampening feet designed for horizontal mounting configurations
  • TIG-welded casing construction for long-term structural integrity
  • Silicon carbide mechanical seal components for fluid containment
SPECIFICATIONS
Max Flow73.3 L/Min
Max Head14.6 m
Power0.3 kW / 415v
Rated Current1.08 Amps
Suitable ForCooling Systems
Body MaterialAISI 304 Stainless Steel
Liquid Temperature'-10°C to +120°C
Inlet Size25 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

Small cooling loops and clean-water circulation systems benefit from dependable movement through compact equipment arrangements. The Lowara 3HM02S03T suits process circulation and building-service applications where steady liquid delivery is required within restricted installation areas.

  • Cooling Loops
  • Process Circulation
  • Clean Water Supply
  • Building Services

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
What peak delivery flow rate does this close-coupled multistage pump provide across plumbing?

Discharge delivery flow peaks at a volume of approximately 73.3 L/Min on the 3HM02S03T, connecting via threaded Rp 1" (25 mm) suction and Rp 1" (25 mm) discharge.

How does the stainless construction protect this multistage booster from aggressive mineral attack?

All-metal stainless construction ensures the 3HM-02S-03T defends against chemical attack and fluid corrosion using AISI 304 stainless steel throughout.

What kilowatt rating and full-load electrical current draw apply to this three-phase supply pump?

Operating a motor power rating of 0.30 kW (0.4 HP), the 3HM 02S 03T connects to a 380–415 V, 50 Hz, three-phase power feed with an electrical running current of 1.08 A.

How does an in-line check valve prevent reverse flow in this horizontal commercial water pump?

Protection against backflow on the 3HM_02S_03T requires installing an external non-return check valve, with the pump mounted on a horizontal base with drainage.

What peak dynamic head and upward lift capability does this pressure pump maintain?

Vertical fluid lift reaches a maximum dynamic head of approximately 14.9 m through the staged impellers of the 3HM02S03T.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed