Lowara 3HM11S11T Stainless Steel Compact Multistage Centrifugal Pump for Process Water with Closed Impeller
SKU: 3HM11S11T

Lowara 3HM11S11T Stainless Steel Compact Multistage Centrifugal Pump for Process Water with Closed Impeller

$1,660.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
73.3 L/Min
Max Head
82 m
Power
1.1 kW / 415v
Ideal Use
Process Water Handling

Product Overview

The Lowara 3HM11S11T provides efficient and reliable pumping performance. Suction-side fluid handling in high-pressure industrial environments requires the mechanical precision found in this horizontal multistage assembly. By utilizing a compact architecture, the unit manages steady liquid transport for process water applications where space efficiency remains critical. The integration of high-grade materials allows for consistent operation across demanding temperature cycles, ensuring the hydraulics remain stable throughout continuous duty cycles in professional infrastructure.

Operational performance thresholds are defined by a Max Head 82 m alongside a Max Flow 73.3 L/Min. Power input is provided by a 1.1 kW motor designed for 415v supply, ensuring balanced circulation for systems requiring precise flow control. The combination of multi-stage hydraulic design and optimized motor output delivers sustained performance levels for complex fluid loops, maintaining pressure integrity even during peak demand intervals.

Fluid dynamics are governed by a series of stainless steel components engineered to minimize turbulence and maximise hydraulic efficiency. The multistage arrangement enables the pump to reach higher pressures than standard single-stage designs while maintaining a compact footprint. Internal clearances are held to precise tolerances, ensuring that kinetic energy conversion is maximized within the AISI 304 housing structure during continuous operation.

Constructed with a fully AISI 304 stainless steel casing, the unit is protected by an IP55 motor rating. The TEFC, 2-pole squirrel-cage motor ensures thermal management during active cycles, while the 25mm suction and delivery ports provide standard integration into existing supply manifolds. Engineered for resilience, the internal seals are selected for broad chemical compatibility, making this an effective solution for specialized circulation tasks.

Features:

  • TEFC 2-pole asynchronous squirrel-cage motor configuration
  • IP55 motor protection for environmental resilience
  • WRAS and ACS certification for drinking water contact
  • TIG-welded external sleeve for structural reinforcement
  • ISO 9906:2012 Grade 3B hydraulic compliance standards
  • Class 155 (F) insulation for thermal endurance
SPECIFICATIONS
Max Flow73.3 L/Min
Max Head82 m
Power1.1 kW / 415v
Rated Current2.21 Amps
Suitable ForProcess Water Handling
Body MaterialAISI 304 Stainless Steel
Liquid Temperature'-10°C to +120°C
Inlet Size25 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

High-pressure process-water circuits require dependable circulation when space-efficient equipment must support continuous liquid transfer. The Lowara 3HM11S11T fits these applications across cooling, water supply and specialised circulation systems.

  • Process Water
  • Cooling Systems
  • Water Supply
  • Liquid Circulation

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
What maximum vertical elevation head does this commercial multistage unit achieve?

Vertical supply pressure reaches a maximum dynamic head of approximately 83.3 m on the 3HM11S11T.

What peak delivery flow rate can this horizontal multistage unit provide through its outlet?

Water delivery capacity through Rp 1" (25 mm) suction and Rp 1" (25 mm) discharge reaches a maximum flow volume of approximately 73.3 L/Min on the 3HM-11S-11T.

How does the stainless casing construction protect this booster from mineral attack and corrosion?

Resisting mineral corrosion and chemical attack, the 3HM 11S 11T employs AISI 304 stainless steel casing alloys and precision closed stainless impellers.

What motor power rating in kilowatt and electrical current draw apply to this circulation booster?

Electrical feed on the 3HM_11S_11T requires a 380–415 V, 50 Hz, three-phase connection, delivering a motor power rating of 1.1 kW (1.5 HP) at an electrical current of 2.21 A.

What horizontal installation positioning and floor drainage clearance apply to this pressure booster?

Anchoring guidelines for the 3HM11S11T call for a level horizontal foundation base with drainage, alongside an external check valve to stop reverse flow.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed