Product Overview
The Lowara 5HM02S05M is engineered for consistent liquid movement in industrial and building service environments. This horizontal multistage centrifugal pump is configured to manage clean fluids, providing a stable hydraulic output that is essential for complex cooling circuits and municipal water circulation. Its architecture is purpose-built to handle continuous operation with minimal friction, ensuring that liquid transfer remains predictable during peak system requirements.
Designed for demanding hydraulic duties, this model achieves a Max Head 14.3 m and a Max Flow 142 L/Min. The unit operates with a 0.5 kW motor at 240v, balancing energy consumption with flow requirements. Internal dimensions and connections are structured with a 32 mm suction and a 25 mm delivery port, accommodating standard industrial plumbing configurations while maintaining the integrity of the hydraulic path under rated pressure loads.
This pump utilizes a multistage arrangement that sequences pressure build-up through a series of stages to reach efficient flow characteristics. The fluid dynamics are optimized by a high-grade AISI 304 stainless steel construction, which minimizes turbulence and ensures the structural integrity of the flow channel. The assembly is designed to provide steady, vibration-dampened performance, which contributes to the longevity of the mechanical components during frequent startup cycles.
The construction features a TEFC motor arrangement integrated into a compact, close-coupled design that simplifies installation in space-constrained mechanical rooms. The pump body is fabricated for durability and corrosion resistance, complemented by an IPX5 protection rating for the assembled unit. The mechanical components and motor housing are engineered to support long-term operation within liquid temperatures ranging from -10°C to +60°C, providing a flexible solution for varying environmental conditions.
Features:
- TEFC motor enclosure with IP55 ingress protection
- Squirrel-cage asynchronous motor configuration
- WRAS and ACS certified for potable liquid handling
- Operating environment temperatures from -15°C to +45°C
- Includes integrated automatic reset overload thermal protection
- Precision-engineered AISI 304 stainless steel hydraulic assembly
SPECIFICATIONS
| Max Flow | 142 L/Min |
| Max Head | 14.3 m |
| Power | 0.5 kW / 240v |
| Rated Current | 2.51 Amps |
| Suitable For | Cooling Systems |
| Body Material | AISI 304 Stainless Steel |
| Liquid Temperature | '-10°C to +60°C |
| Inlet Size | 32 mm |
| Outlet Size | 25 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Where is horizontal foundation mounting recommended for this booster and how is backflow prevented?
Securing the 5HM02S05M in a horizontal orientation on a level foundation base with drainage ensures proper operation, while an external check valve protects the system against reverse flow.
What dynamic head and vertical lift elevation can this multistage pump generate?
Lifting clean water upward through elevation rises, the 5HM-02S-05M attains a maximum dynamic head performance of approximately 14.9 m.
What maximum water flow rate and suction discharge pipe threads apply to this booster?
Discharging through its outlet port, the 5HM 02S 05M delivers a peak water flow rate of approximately 142 L/Min utilizing Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge.
What stainless alloy metallurgy and closed impellers protect this booster from fluid corrosion?
Metallurgical materials on the 5HM_02S_05M incorporate an AISI 304 stainless steel pump casing and closed stainless impellers, delivering superior durability against abrasive particulate erosion and corrosion.
What electrical kilowatt rating and single-phase supply voltage feed this multistage pump?
Electrical supply requirements for the 5HM02S05M comprise a 220–240 V, 50 Hz, single-phase feed, energizing the 0.50 kW (0.7 HP) motor power at an electrical current of 2.51 A.