Lowara 5HM04P07M Stainless Steel Precise Multistage Centrifugal Pump for Boosting with Technopolymer Impeller
SKU: 5HM04P07M

Lowara 5HM04P07M Stainless Steel Precise Multistage Centrifugal Pump for Boosting with Technopolymer Impeller

$1,281.17 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
120 L/Min
Max Head
41.5 m
Power
0.75 kW / 240v
Ideal Use
Residential and Commercial Pressure Boosting

Product Overview

Engineered for versatility, the Lowara 5HM04P07M horizontal multistage centrifugal pump supports clean water supply and pressure boosting across residential and medium-sized commercial sectors. This unit is specifically configured for irrigation systems, water treatment processes, and climate control installations where consistent, quiet performance is required. Its compact architecture facilitates integration into tight utility spaces, providing a solution for facilities that demand dependable liquid movement without the footprint of larger industrial pumps.

The hydraulic assembly delivers reliable output with a maximum capacity of Max Head 41.5 m and Max Flow 120 L/Min. Powered by a 0.75 kW motor at 240v, the system balances energy efficiency with flow output. Engineered with a durable 32 mm suction and 25 mm delivery connection, the pump manages clean liquids effectively while maintaining structural integrity. The use of technopolymer impellers ensures smooth fluid dynamics, minimizing vibration throughout the operational range to preserve the longevity of the motor.

Construction relies on a high-grade AISI 304 stainless steel body, offering resistance to corrosion in various aqueous environments. The TEFC squirrel-cage motor configuration provides thermal stability and protection, while the balanced impeller design reduces axial thrust during peak demand. This series features a single-piece fabricated body with a precision O-ring seal, specifically designed to mitigate leakage risks and ensure long-term hydraulic efficiency for continuous-duty applications.

Installation is simplified by standard metric cable glands and a robust motor adapter, allowing for rapid integration into existing plumbing configurations. The pump includes integrated automatic reset thermal protection for safe operation during fluctuating usage cycles. Designed for clean water handling, this equipment should be positioned in well-ventilated areas to optimize ambient cooling. The IPX5 enclosure provides protection against water jets, making it suitable for varied indoor or sheltered outdoor utility environments.

Features:

  • Certified for drinking water contact under WRAS and ACS standards
  • Balanced rotating components reduce mechanical stress on bearings
  • Simplified single-piece housing design minimizes gasket leak points
  • High-efficiency motor performance reduces energy consumption per litre
  • Metric cable entry points streamline electrical site connections
  • Asynchronous TEFC motor architecture for consistent thermal management
  • AISI 304 stainless steel fluid-contact surfaces for corrosion resistance
SPECIFICATIONS
Max Flow120 L/Min
Max Head41.5 m
Power0.75 kW / 240v
Rated Current4.58 Amps
Suitable ForResidential and Commercial Pressure Boosting
Body MaterialAISI 304 Stainless Steel
Liquid TemperatureMaximum 60°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

Clean-water treatment and pressure-management duties can be handled by the Lowara 5HM04P07M across cooling and filtration systems. Its compact multistage arrangement suits utility rooms and building services where space-efficient circulation is needed.

  • Water Treatment
  • Pressure Boosting
  • Cooling Systems
  • Water Filtration

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
Where should this pressure boosting multistage pump be installed on a horizontal foundation base?

Horizontal multistage surface installation on a rigid concrete base is specified for the 5HM04P07M, featuring an integrated setup with proper drainage.

What total dynamic elevation head is produced by this pressure boosting multistage pump?

Operating with multiple hydraulic stages, the 5HM-04P-07M attains a peak dynamic elevation head of approximately 47.6 m under full load.

What maximum delivery flow rate is produced by this pressure boosting multistage unit?

Pressure boosting distribution circuits receive a maximum delivery flow of approximately 120 L/Min from the 5HM 04P 07M through its Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge connections.

What metallurgy and stage materials are engineered into this pressure booster to prevent chemical attack?

Hydraulic longevity in pressure boosting circuits relies on alloy metallurgy materials in the 5HM_04P_07M, featuring AISI 304 stainless steel pump casing, Technopolymer impellers, and ceramic/carbon/EPDM mechanical seal to prevent fluid corrosion across temperatures from -10°C to +90°C.

What single-phase supply voltage and electrical power input operate this pressure boosting unit?

Driving the hydraulic assembly of the 5HM04P07M mandates a 0.75 kW motor input on 220–240 V, 50 Hz, single-phase at 4.79 A, supported by IP55 dust and water spray protection, Class F insulation.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us