Lowara 5HM04S05M Stainless Steel IE3 Multistage Centrifugal Pump for System Boosting with Closed Impeller
SKU: 5HM04S05M

Lowara 5HM04S05M Stainless Steel IE3 Multistage Centrifugal Pump for System Boosting with Closed Impeller

$985.00 GST Included
FREE shipping on orders over $100 Australia-wide*
Fast Dispatch
Australia-Wide
Expert Advice
(08) 9240 2992
Genuine
Official Lowara
12 Months
Peace of Mind
Max Flow
142 L/Min
Max Head
27.2 m
Power
0.5 kW / 240v
Ideal Use
Cooling Systems

Product Overview

Engineered for versatility in building services and light industrial environments, this horizontal multistage centrifugal pump is designed to handle clean liquids across varied operational requirements. The 5HM04S05M configuration effectively addresses needs for secondary system boosting, circulation tasks, and process water handling, ensuring consistent hydraulic performance even in space-constrained installations. By integrating the pump body directly with the motor flange, the unit maintains a compact, one-piece footprint while minimizing potential leak points in the hydraulic circuit.

The system achieves a Max Head 27.2 m and a Max Flow 142 L/Min, driven by a 0.5 kW / 240v motor. The hydraulic design utilizes premium AISI 304 stainless steel, prioritizing structural integrity and chemical resistance when processing clean media. Its multistage configuration allows for stable pressure generation suitable for irrigation systems, pressure boosting in multi-storey residential buildings, and closed-loop temperature control setups where consistent fluid movement is essential for operational stability.

Hydraulic efficiency is central to the design, utilizing advanced impeller geometry to optimize flow paths through each of the internal stages. This staging arrangement facilitates high-pressure output without excessive electrical demand, promoting energy-efficient fluid transfer. The pump utilizes a robust shaft assembly that works in unison with the stainless steel internal components to prevent cavitation and reduce vibration, even during sustained operation under maximum load conditions.

Installation is simplified through a close-coupled arrangement that utilizes an IPX5 protection rating, safeguarding internal components from moisture ingress and external debris. Plumbing is accommodated via a 32 mm suction and 25 mm delivery port configuration, providing compatibility with standard piping systems. The TEFC motor design ensures cool operation and consistent duty cycles, making this unit a suitable choice for environments requiring long-term, low-maintenance clean liquid transport.

Features:

  • Integrated squirrel-cage TEFC motor with IE3 efficiency classification
  • WRAS and ACS certified for safe potable water distribution
  • Single O-ring casing sealing architecture for enhanced leak resistance
  • AISI 304 stainless steel hydraulic construction throughout
  • Enclosed fan-cooled design for consistent thermal dissipation
  • Designed for compliance with strict EN 60335-2-41 safety standards
SPECIFICATIONS
Max Flow142 L/Min
Max Head27.2 m
Power0.5 kW / 240v
Rated Current3.18 Amps
Suitable ForCooling Systems
Body MaterialAISI 304 Stainless Steel
Liquid Temperature'-10°C to +60°C
Inlet Size32 mm
Outlet Size25 mm
Warranty12 Months
Documents
Specification Datasheet Download
Product Brochure Download
Installation Manual Download

Secondary water systems, irrigation layouts and temperature-control circuits can rely on the Lowara 5HM04S05M where clean liquid needs to move consistently between connected points. Its application range also includes multi-storey water supply and service circulation.

  • Secondary Water Supply
  • Garden Irrigation
  • Temperature Control
  • Multi-storey Supply

Warranty & Returns

All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.

  • Products must be installed correctly and in accordance with the manufacturer’s instructions.
  • Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
  • Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
  • The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
  • Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
  • Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
  • Customers are responsible for return freight costs for change-of-mind returns.
  • Restocking fees may apply to special-order, bulky or non-stocked products.
  • Used, installed or specially ordered products may not be eligible for change-of-mind returns.
  • If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.

Your rights under Australian Consumer Law are not affected.

Specification Datasheet
Download
Product Brochure
Download
Installation Manual
Download
What water flow volume and connection pipe dimensions are engineered into this unit?

Supplying steady fluid flow across piping circuits, the 5HM04S05M provides a maximum delivery flow volume of approximately 142 L/Min with Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge.

What metallurgy and mechanical seal materials provide corrosion resistance in this unit?

Resisting fluid corrosion and mineral attack, the 5HM-04S-05M utilizes an AISI 304 stainless steel pump body, matching AISI 304 stainless closed impellers, and chemical attack resistant mechanical seal materials.

What electrical motor power in kilowatt and full-load current draw apply to this circulation pump?

Electrical power feed for the 5HM 04S 05M requires a 220–240 V, 50 Hz, single-phase connection, delivering a motor power rating of 0.50 kW (0.7 HP) with an electrical running current of 3.18 A.

Where should this multistage circulation pump be installed on a level horizontal base for drainage?

To prevent reverse flow and maintain line pressure, the 5HM_04S_05M must be paired with an external non-return check valve while anchored securely on a horizontal mounting base with proper drainage.

What maximum dynamic head and fluid lift capability apply to this circulation unit?

Elevating water through vertical supply lines, the 5HM04S05M achieves a peak dynamic head rating of approximately 29.2 m at full elevation push.

Need help choosing the right pump?

Our team of pump experts are here to help you find the perfect solution for your application.

  • Free expert advice
  • Pump sizing & system recommendations
  • Fast response — call or email us

Recently viewed