Roll over image to zoom
SKU: 5HM04S05T
Lowara 5HM04S05T Stainless Steel Insulated Multistage Centrifugal Pump for Supply Chains with Closed Impeller
Australia-Wide
(08) 9240 2992
Official Lowara
Peace of Mind
Product Overview
The Lowara 5HM04S05T is a precision-engineered pump. Suction-side fluid movement in high-demand technical environments necessitates the performance characteristics provided by this horizontal multistage configuration. Specifically engineered for reliability within municipal supply loops and agricultural irrigation sites, the assembly handles varying liquid demand with consistent mechanical stability. The close-coupled design minimises footprint while allowing for efficient integration into existing horizontal plumbing layouts where space is at a premium and throughput speed remains a critical operational factor.
Operational threshold limits are defined by a Max Head 27.2 m alongside a Max Flow 142 L/Min. Driving these fluid dynamics is a 0.5 kW / 415v motor, which adheres to IE3 efficiency standards to reduce energy consumption during continuous operation. The hydraulic path remains uniform, ensuring that the pressure generated is maintained across the entire duty cycle, making the Lowara 5HM04S05T unit a precise choice for process-critical water delivery tasks.
Fluid dynamics are governed by a multi-stage arrangement featuring high-grade stainless steel components that minimise friction loss. By utilising a closed-impeller architecture, the pump achieves a balance between pressure development and volume displacement, allowing for rapid lift and smooth flow transition. This internal configuration is specifically calibrated to handle clear liquids without the turbulence often found in simpler single-stage pumping setups.
Housing consists of AISI 304 stainless steel, selected for its balance between structural strength and chemical resistance in neutral to mildly aggressive fluid conditions. The motor is protected to IP 55 standards, safeguarding the internal windings against dust and moisture ingress, while the TEFC design provides sufficient thermal regulation during extended usage periods. Mounting is facilitated by a robust foot-bracket system that dampens vibration and ensures alignment remains constant during high-speed rotation cycles.
Features:
- TEFC 2-pole asynchronous motor configuration
- Silicon carbide and carbon mechanical seal interface
- EPDM elastomer gaskets for high-temp fluid stability
- Compliant with ISO 9906:2012 Grade 3B hydraulic standards
- AISI 304 stainless steel pump casing and support housing
- Class F insulation for elevated motor thermal protection
SPECIFICATIONS
| Max Flow | 142 L/Min |
| Max Head | 27.2 m |
| Power | 0.5 kW / 415v |
| Rated Current | 1.51 Amps |
| Suitable For | Process Water Handling |
| Body Material | AISI 304 Stainless Steel |
| Liquid Temperature | '-10°C to +120°C |
| Inlet Size | 32 mm |
| Outlet Size | 25 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What peak vertical elevation head is produced by this cooling multistage pump?
Elevating water across plant piping networks, the 5HM04S05T produces a maximum dynamic head of approximately 29.3 m.
What peak fluid delivery volume can this multistage cooling pump discharge through its outlet?
Peak delivery volume on the 5HM-04S-05T achieves a water flow capacity of approximately 142 L/Min utilizing Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge.
How does the all-stainless construction defend this cooling pump against chemical attack?
All-metal AISI 304 stainless steel metallurgy protects the 5HM 04S 05T against aggressive fluid corrosion across all hydraulic passages.
What electrical motor power in kilowatt and full-load current draw apply to this circulation pump?
Electrical supply integration for the 5HM_04S_05T requires a 380–415 V, 50 Hz, three-phase connection, powering the 0.50 kW (0.7 HP) motor at an electrical current of 1.51 A.
What horizontal mounting orientation and non-return check valve setup apply to this cooling pump?
Eliminating backflow in horizontal plumbing lines requires installing an external non-return check valve downstream of the 5HM04S05T on a drained base.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us