Product Overview
Engineered for versatility in building services and industrial liquid management, the Lowara 5HM11S15M serves as a reliable horizontal multistage centrifugal solution. This pump is specifically configured to manage clean water transfer where flow stability and pressure consistency are essential. Its architectural design allows for seamless integration into diverse hydraulic networks, offering a direct response to the requirements of modern irrigation systems and residential supply lines where effective movement of clean fluids is mandatory.
The pump exhibits significant hydraulic capability, reaching a Max Head 78.2 m and a Max Flow 142 L/Min. Powering this unit is an IE3 efficient motor, utilizing a 1.5 kW draw at 240v. The mechanical assembly utilizes a 32 mm inlet and a 25 mm outlet to accommodate standard plumbing configurations. Thermal performance is managed within an operating envelope suitable for liquids ranging from -10°C to +60°C, ensuring that the assembly maintains its operational integrity across varied ambient environmental conditions.
Fluid dynamics are optimized through the use of AISI 304 stainless steel impellers, which minimize cavitation potential while maximizing energetic efficiency. The multistage arrangement effectively stacks hydraulic pressure, providing a steady output even under fluctuating demand. This series prioritizes laminar flow characteristics, reducing internal friction losses and providing consistent delivery across the entire performance curve, supporting long-term reliability in continuous duty cycles.
Designed with a TIG-welded external sleeve and a robust bracket for structural rigidity, the unit employs a dual O-ring seal system to minimize maintenance intervention points. The TEFC motor is shielded under an IPX5 rating, providing protection against fluid ingress, while the insulation class 155 (F) handles thermal fluctuations during startup and high-load operation. The connection ports use standard Rp threading for straightforward field piping, and the overall construction leverages high-grade stainless steel to ensure longevity in fluid contact areas.
Features:
- WRAS and ACS certification for safe drinking water circulation
- TEFC motor enclosure with IP55 rating for environmental shielding
- Standardized Rp threaded connections for simplified pipe integration
- AISI 304 stainless steel liquid-contact components for corrosion resistance
- Thermal management optimized for continuous operation cycles
- Integrated 2-pole squirrel cage rotor geometry for precise speed stability
SPECIFICATIONS
| Max Flow | 142 L/Min |
| Max Head | 78.2 m |
| Power | 1.5 kW / 240v |
| Rated Current | 8.42 Amps |
| Suitable For | Industrial cooling systems and process water supply |
| Body Material | AISI 304 Stainless Steel |
| Liquid Temperature | '-10°C to +60°C |
| Inlet Size | 32 mm |
| Outlet Size | 25 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What kilowatt rating and electrical supply voltage run this single-phase circulation motor?
Powered by a 220–240 V, 50 Hz, single-phase electrical feed, the 5HM11S15M delivers a motor power rating of 1.5 kW (2.0 HP) at an electrical current draw of 8.42 A.
How does an external check valve prevent reverse flow across this horizontal circulation booster?
Backflow prevention across horizontal pipe runs requires installing an external non-return check valve immediately downstream of the 5HM-11S-15M, which must rest on a horizontal base with drainage.
What maximum vertical head and fluid lift elevation does this cooling pump provide?
Vertical lift pressure is developed by the 5HM 11S 15M, which maintains a peak dynamic head of approximately 82.0 m across its stages.
What maximum delivery flow rate does this multistage cooling pump discharge across piping?
Plumbing connection lines interface with the 5HM_11S_15M via Rp 1-1/4" (32 mm) suction and Rp 1" (25 mm) discharge, discharging a maximum delivery flow volume of approximately 142 L/Min.
Which construction materials safeguard the hydraulic stages of this pump against particulate wear?
Corrosion defense across the 5HM11S15M relies on high-grade AISI 304 stainless steel casing alloys and closed stainless impellers with EPDM elastomers to protect against chemical attack.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us