Roll over image to zoom
SKU: NSCS40-125/40
Lowara NSCS40 125/40 Stainless Steel Single Stage Centrifugal Pump for Washing Lines with Closed Impeller
Australia-Wide
(08) 9240 2992
Official Lowara
Peace of Mind
Product Overview
Integrates efficiently into demanding industrial washing lines, the Lowara NSCS40-125/40 provides heavy-duty liquid handling for continuous cleaning applications. The robust architectural framework ensures steady fluid movement in rigorous commercial environments.
Pushing a formidable maximum flow of approximately 930 L/Min, this unit achieves a maximum head of approximately 26.5 m. It operates on a 4.0 kW / 415v three-phase motor, utilizing a large 65 mm suction port alongside a 40 mm discharge outlet.
The internal casing geometry is specifically optimized to prevent pressure drop-offs during high-velocity transfer. By relying on a dynamically balanced centrifugal mechanism, it directly minimizes flow separation and reduces mechanical strain on attached piping.
Built with a resilient Cast Iron external volute and a Fabricated Stainless Steel (AISI 316) impeller, it comfortably manages liquid temperatures up to +120 °C. The stub shaft adapter ensures secure motor alignment, protected by a continuous-duty IP55 enclosure.
FEATURES
- Heavy-duty stub shaft adapter alignment
- Cast Iron outer structural pumping volute
- Fabricated AISI 316 Stainless Steel impeller
- Standardized three-phase continuous duty motor
- IP55 environmental moisture protection
- Rapid access back pull-out construction
- Thermal liquid handling peaking at +120 °C
SPECIFICATIONS
| Max Flow | 930 L/Min |
| Max Head | 26.5 m |
| Power | 4 kW / 415v |
| Rated Current | 7.57 Amps |
| Suitable For | HVAC and Industrial Process Water |
| Body Material | AISI 316 Stainless Steel |
| Liquid Temperature | '-25°C to +120°C |
| Inlet Size | 65 mm |
| Outlet Size | 40 mm |
| Warranty | 12 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
To elevate liquid upward, what maximum vertical head does this flanged end-suction centrifugal pump reach?
Lifting across building service lines, the NSCS40-125/40 attains a peak dynamic elevation head of approximately 26.5 m propelling fluid upward.
Through connected discharge piping, what maximum liquid delivery volume is produced by this flanged end-suction centrifugal pump?
Outputting across facility piping networks, the NSCS40-125-40 sustains a maximum delivery flow capacity of approximately 930 L/Min plumbed with DN 65 suction and DN 40 discharge flanged ports.
In aggressive fluid duty, what alloy metallurgy and mechanical seals prevent corrosion in this flanged end-suction centrifugal pump?
Machined with corrosion-resistant alloy materials, the NSCS40 125 40 features metallurgy of cast iron casing with stainless steel closed impellers complemented by precision mechanical seals to eliminate corrosion leaks.
Under facility power distribution, what electrical supply voltage and motor current draw support this flanged end-suction centrifugal pump?
Operated by facility power panels, the NSCS40_125_40 is driven by an electric motor rated at 4 kW (5.5 HP) powered by 380–415 V, 50 Hz, three-phase drawing 7.62 / 4.40 A.
What operating pressure rating in bar and permissible fluid temperature range govern this flanged end-suction centrifugal pump?
Sustaining under demanding fluid temperatures, the NSCS40-125/40 withstands a maximum working pressure limit of 16 bar (PN 16) with fluid temperatures ranging from -25°C to +120°C.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us