Agricultural distribution infrastructure and municipal complexes utilize the ZN895-02/2B-3R multistage submersible unit for aquifer extraction. This model features a Duplex Stainless Steel motor configuration and belongs to the ZN895 range, offering robust lifting for aquifers. It allows for vertical installation in borehole wells or horizontal deployment provided a minimum inclination ensures motor immersion.
Constructed from cast 316 Stainless Steel, the delivery head and suction casing provide structural integrity for borehole service life. The two-stage hydraulics utilize reduced diameter impellers designed to process liquids containing suspended sand up to 100 g/m³. The unit weighs 90.2 kg and operates in liquids reaching a maximum temperature of 25°C.
The 11 kW motor utilizes a 415v supply with a rated current of 24.2 Amps for deep-well duty. It achieves a maximum total head of 38.4 m and a maximum flow rate of 1966.7 L/Min through a semi-axial hydraulic geometry. This configuration provides the pressure maintenance infrastructure needed for municipal distribution systems and intensive water distribution loops.
Safety containment features Class F motor insulation and an IP68 rating for submerged service in borehole environments. The assembly supports immersion depths reaching 350 meters and utilizes double mechanical shaft seals for fluid containment. Internal technopolymer POM-C wear rings and EPDM bearing bushes support the duplex stainless steel shaft assembly and maintain precise clearances.
FEATURES
- Mechanical connection of the 8-inch motor follows NEMA standards for compatibility with industrial systems.
- A duplex stainless steel taperlock system secures the semi-axial impellers to the shaft for torque transfer.
- Stainless steel cable covers provide mechanical protection for the power leads along the pump casing.
- Internal technopolymer POM-C wear rings maintain hydraulic clearances and reduce internal friction.
- EPDM 70 bearing bushes support the pump shaft assembly and handle the mechanical loads during rotation.
- A stainless steel suction strainer is fitted to exclude large solid particles from entering the hydraulic stages.
- The integrated non-return valve features a stainless steel spring to prevent liquid backflow and water hammer.
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
How much maintenance does the Lowara ZN895-02/2B-3R need?
Virtually none. The sealed bearings and shaft seals are lubricated for life, giving you years of trouble-free daily pumping.
How deep can the Lowara ZN895-02/2B-3R push water from underground?
With a maximum head of 38.4 m, it easily lifts water from deep bore shafts and pushes it across long pipe runs without losing pressure.
Can the Lowara ZN895 02 2B 3R handle dirty or gritty bore water?
The pump is designed for the documented sand/particle conditions; do not exceed the manufacturer's stated limits. The impellers are built from heavy-duty materials designed to resist abrasion and sediment wear.
Can I run the Lowara ZN895-02-2B-3R off a farm generator or solar inverter?
Yes, as long as your generator matches its 11 kW / 415v requirement. It's built for continuous duty on 415V three-phase or standard rural power setups.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us