Roll over image to zoom
SKU: EML600NNAH10000
SEKO Tekba EML 600 Degassing PVDF EPDM Solenoid Dosing Pump
Australia-Wide
(08) 9240 2992
Official SEKO
Peace of Mind
Product Overview
Beverage bottling operations depend on disciplined sanitizer addition across clean-in-place rinse circuits to purge off-gassing vapor bubbles automatically. Dedicated auto-degassing bypass plumbing prevents vapor binding when dosing concentrated peracetic acid or chlorine solutions during sanitization shifts. Onsite operators calibrate stroke frequency via straightforward analogue controls without interrupting production bottle filling lines.
Electromagnetic positive displacement delivers stepped chemical injection across calibrated pressure tiers: 2.3 L/h (0.04 L/Min) at 20 bar, 2.7 L/h (0.05 L/Min) at 18 bar, 3.8 L/h (0.06 L/Min) at 14 bar, and up to 6.3 L/h (0.11 L/Min) at 8 bar (reflecting the 10% auto-degassing bypass derating per the SEKO 2026 AUS Price List vs. standard head datasheet ratings of 2.5 to 7.0 L/h), with a stroke capacity of 0.35–0.97 cc/stroke. The wetted assembly integrates an auto-degassing PVDF pump head that automatically vents entrapped vapor bubbles, coupled with double ceramic check valve balls, a solid PTFE diaphragm, and EPDM seals, with a dry net weight of 3.9 kg (SEKO 2026 W&I Catalogue, p. 15). A complete PVDF installation kit is supplied, including a PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
Operating from a stabilized 100–240 VAC (50/60 Hz) switch-mode power supply with an energy draw of 14.0–19.0 W, the drive operates up to 120 strokes per minute using 4/6 mm plumbing connections. Constant-flow regulation is configured via the rear-panel digital keyboard and display for stroke frequency setup across operating rates, alongside an external circular connector for a low-chemical level probe.
Built with an IP65 fiberglass-reinforced polypropylene casing, the housing withstands wet plant washdowns and corrosive chemical fumes. Sealed external circular IP65 plugs enable all electrical and signal wiring to be terminated without exposing internal circuitry. Base-mounting slots facilitate fast installation on dosing skids or chemical reservoirs. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- Calibrated chemical metering supplying up to 6.3 L/h (0.11 L/Min) against line backpressures to 20 bar (200 m head)
- Self-venting PVDF wetted assembly with double ceramic check valve balls preventing gas locking during off-gassing chemical cycles
- Alkali-resistant EPDM wetted O-rings providing seal stability when dosing high-pH chemical fluids
- Solid pure PTFE diaphragm delivering total chemical isolation with no composite layers to delaminate
- Digital microprocessor interface on rear panel allowing direct frequency setup from 0 to 100% without halting operations
- Energy-conserving 100–240 VAC multi-power supply consuming 14.0–19.0 W with stabilized solenoid coil pulsing
- Factory-supplied PVDF accessory kit featuring weighted foot valve, injection quill, 4 m suction/bleed tubing, and 2 m discharge tubing for 4/6 mm ports
- Protective IP65 enclosure guarding internal electronics from corrosive plant atmospheres and low-pressure washdown spray
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 0.11 L/Min |
| Max Head | 200 m |
| Power | 0.019 kW / 240v |
| Suitable For | Pressurized Bleach Injection |
| Body Material | Degassing PVDF |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (4/6 mm) |
| Outlet Size | Hose Connection (4/6 mm) |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What electrical supply voltage and operational wattage draw are required by this unit?
Operational energy demand across SEKO Tekba EML 600 Degassing PVDF EPDM Solenoid Dosing Pump utilizes a stabilized 100–240 VAC at 50/60 Hz switch-mode connection drawing 14.0–19.0 W at stroke rates up to 120 strokes per minute.
What chemical contact components and accessory fittings comprise this dosing unit?
Fluid path materials across EML600NNAH10000 feature an auto-degassing PVDF pump head that automatically vents entrapped vapor bubbles, double ceramic check valve balls, a solid PTFE diaphragm, and EPDM seals, and includes a complete PVDF installation kit with PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
What chemical delivery adjustment controls and signal inputs does this unit offer?
Dosing flow regulation on EML-600-NNAH-10000 incorporates constant-flow regulation configured via a rear-panel digital keyboard and display for stroke frequency setup across operating rates, plus an external circular connector for a low-chemical level probe.
Which manufacturer warranty parameters and diaphragm coverage support this pump?
Factory warranty protection for EML 600 NNAH 10000 provides comprehensive manufacturer coverage backed by a 5-year solid PTFE diaphragm guarantee, subject to sheltered mounting up to 40°C and chemical fluid compatibility.
What fluid transfer throughput and delivery pressure are developed by this unit?
Calibrated chemical metering on Tekba EML 600 (EML600NNAH10000) generates positive displacement output across operating tiers: 2.3 L/h or 0.04 L/Min at 20 bar, 2.7 L/h or 0.05 L/Min at 18 bar, 3.8 L/h or 0.06 L/Min at 14 bar, and up to 6.3 L/h or 0.11 L/Min at 8 bar, reflecting the 10 percent auto-degassing bypass derating per the SEKO 2026 AUS Price List vs standard head datasheet ratings of 2.5 to 7.0 L/h, with a stroke capacity of 0.35–0.97 cc/stroke.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us