Product Overview
Wastewater clarification tanks utilize dedicated coagulant delivery to flocculate suspended solids effectively under elevated system injection backpressure. The inert fluoropolymer liquid end withstands aggressive chemical attack from concentrated mineral salts and coagulating agents. Treatment plant personnel calibrate stroke rates directly using front digital controls to achieve effective liquid floc formation.
Solenoid-actuated positive displacement supplies calibrated chemical dosing across defined pressure tiers: 2.5 L/h (0.04 L/Min) at 20 bar, 3.0 L/h (0.05 L/Min) at 18 bar, 4.2 L/h (0.07 L/Min) at 14 bar, and up to 7.0 L/h (0.12 L/Min) at 8 bar, with a stroke capacity of 0.35–0.97 cc/stroke. The wetted liquid end incorporates a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, with a dry net weight of 3.9 kg (SEKO 2026 W&I Catalogue, p. 15). A complete PVDF installation kit is supplied, including a PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
An integrated switch-mode power supply accepts 100–240 VAC (50/60 Hz) line power drawing 14.0–19.0 W, pulsing the solenoid at frequencies up to 120 strokes per minute through 4/6 mm fluid connections. Constant-flow regulation is configured via the rear-panel digital keyboard and display for stroke frequency setup across operating rates, alongside an external circular connector for a low-chemical level probe.
The IP65 fiberglass-reinforced polypropylene housing protects internal components against airborne chemical vapors and low-pressure water washdown. Factory-sealed circular IP65 connectors allow all signal cables to wire directly into the exterior without casing disassembly. Standard mounting feet bolt directly onto dosing skids. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- High-backpressure chemical dosing capacity delivering up to 7.0 L/h across four calibrated pressure stages
- High-purity PVDF wetted assembly with double ceramic non-return valves providing positive directional flow
- Resilient FKM-B elastomeric sealing providing fluid isolation during biocide injection
- Pure solid PTFE diaphragm providing fatigue resistance during operational pulsing
- Electronic constant-flow regulation via rear digital keypad with dedicated circular connection for chemical tank level sensor
- Wide-range 100–240 VAC (50/60 Hz) electrical input drawing 14.0–19.0 W maintaining consistent stroke force across voltage fluctuations
- Comprehensive PVDF installation package with suction strainer, injection non-return valve, and chemical tubing for 4/6 mm plumbing
- Industrial IP65 polypropylene housing featuring external circular quick-connect ports to wire power and signals without opening the unit
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 0.12 L/Min |
| Max Head | 200 m |
| Power | 0.019 kW / 240v |
| Suitable For | Pressurized Sulfuric Acid |
| Body Material | PVDF |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (4/6 mm) |
| Outlet Size | Hose Connection (4/6 mm) |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which wetted liquid end materials and installation fittings are included with this pump?
Fluid path materials across SEKO Tekba EML 600 PVDF FKM-B Solenoid Dosing Pump feature a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, and includes a complete PVDF installation kit with PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
Which dosing regulation mechanisms and monitoring features govern this chemical pump?
Dosing flow regulation on EML600NNHH00000 incorporates constant-flow regulation configured via a rear-panel digital keyboard and display for stroke frequency setup across operating rates, plus an external circular connector for a low-chemical level probe.
What equipment warranty terms and component protections protect this chemical pump?
Factory warranty protection for EML-600-NNHH-00000 provides comprehensive manufacturer coverage backed by a 5-year solid PTFE diaphragm guarantee, subject to sheltered mounting up to 40°C and chemical fluid compatibility.
Which chemical injection capacity and line pressure envelope govern this pump?
Calibrated chemical metering on EML 600 NNHH 00000 generates positive displacement output across operating tiers: 2.5 L/h or 0.04 L/Min at 20 bar, 3.0 L/h or 0.05 L/Min at 18 bar, 4.2 L/h or 0.07 L/Min at 14 bar, and up to 7.0 L/h or 0.12 L/Min at 8 bar, with a stroke capacity of 0.35–0.97 cc/stroke.
What electrical operating voltage and power consumption apply to this pump?
Electric power propulsion for Tekba EML 600 (EML600NNHH00000) operates on a stabilized 100–240 VAC at 50/60 Hz switch-mode supply drawing 14.0–19.0 W while cycling at frequencies up to 120 strokes per minute.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us