Roll over image to zoom
SKU: EML603NNI010000
SEKO Tekba EML 603 SS316L EPDM Solenoid Dosing Pump
Australia-Wide
(08) 9240 2992
Official SEKO
Peace of Mind
Product Overview
High temperature clean-in-place circuits depend on hot caustic soda metering to strip stubborn dairy caramelization from evaporator plates. The metallic stainless head withstands aggressive thermal shock and caustic cleaning chemistry without material breakdown. Process operators adjust chemical feed through front manual controls to maintain hygienic evaporator surfaces between milk concentration cycles.
Electromagnetic positive displacement delivers stepped chemical injection across calibrated pressure tiers: 4.0 L/h (0.07 L/Min) at 12 bar, 5.0 L/h (0.08 L/Min) at 10 bar, 6.0 L/h (0.1 L/Min) at 8 bar, and up to 8.0 L/h (0.13 L/Min) at 2 bar, with a stroke capacity of 0.42–0.83 cc/stroke. The liquid end is precision-machined from AISI 316L stainless steel with double AISI 316L stainless steel check valve balls, a solid PTFE diaphragm, and EPDM seals, with a dry net weight of 3.4 kg (SEKO 2026 W&I Catalogue, p. 15). Supplied as a bare pump assembly without plastic installation kit, ready for direct integration into rigid stainless steel or high-pressure chemical dosing skids.
Operating from a stabilized 100–240 VAC (50/60 Hz) switch-mode power supply with an energy draw of 17.0–22.0 W, the drive operates up to 160 strokes per minute using 4/6 mm plumbing connections. Constant-flow regulation is configured via the rear-panel digital keyboard and display for stroke frequency setup across operating rates, alongside an external circular connector for a low-chemical level probe.
Built with an IP65 fiberglass-reinforced polypropylene casing, the housing withstands wet plant washdowns and corrosive chemical fumes. Sealed external circular IP65 plugs enable all electrical and signal wiring to be terminated without exposing internal circuitry. Base-mounting slots facilitate fast installation on dosing skids or chemical reservoirs. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- Calibrated chemical displacement providing up to 8.0 L/h across tiered pressures up to 12 bar (120 m head)
- Solid 316L stainless steel wetted construction with dual stainless non-return valves resisting solvent wear and thermal stress
- Alkali-resistant EPDM wetted O-rings providing seal stability when dosing high-pH chemical fluids
- Solid pure PTFE diaphragm delivering total chemical isolation with no composite layers to delaminate
- Digital microprocessor interface on rear panel allowing direct frequency setup from 0 to 100% without halting operations
- Energy-conserving 100–240 VAC multi-power supply consuming 17.0–22.0 W with stabilized solenoid coil pulsing
- Skid-ready industrial pump configuration designed for rigid metallic piping systems without plastic accessories
- Protective IP65 enclosure guarding internal electronics from corrosive plant atmospheres and low-pressure washdown spray
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 0.13 L/Min |
| Max Head | 120 m |
| Power | 0.022 kW / 240v |
| Suitable For | Feedwater Alkaline Conditioning |
| Body Material | SS316L |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (4/6 mm) |
| Outlet Size | Hose Connection (4/6 mm) |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What wetted assembly materials and plumbing kit fittings are provided with this unit?
Fluid path materials across SEKO Tekba EML 603 SS316L EPDM Solenoid Dosing Pump feature an AISI 316L stainless steel pump head, double AISI 316L stainless steel check valve balls, a solid PTFE diaphragm, and EPDM seals, and provides 4/6 mm connections designed for direct installation into stainless steel piping.
What dosing adjustment features and communication interfaces are integrated into this unit?
Dosing flow regulation on EML603NNI010000 incorporates constant-flow regulation configured via a rear-panel digital keyboard and display for stroke frequency setup across operating rates, plus an external circular connector for a low-chemical level probe.
Which manufacturer warranty provisions and component stipulations govern this pump?
Factory warranty protection for EML-603-NNI0-10000 provides comprehensive manufacturer coverage backed by a 5-year solid PTFE diaphragm guarantee, subject to sheltered mounting up to 40°C and chemical fluid compatibility.
What volumetric dosing delivery and operating backpressure does this metering unit provide?
Calibrated chemical metering on EML 603 NNI0 10000 generates positive displacement output across operating tiers: 4.0 L/h or 0.07 L/Min at 12 bar, 5.0 L/h or 0.08 L/Min at 10 bar, 6.0 L/h or 0.1 L/Min at 8 bar, and up to 8.0 L/h or 0.13 L/Min at 2 bar, with a stroke capacity of 0.42–0.83 cc/stroke.
Which electrical supply limits and operating wattage draw apply to this unit?
Electric power propulsion for Tekba EML 603 (EML603NNI010000) operates on a stabilized 100–240 VAC at 50/60 Hz switch-mode supply drawing 17.0–22.0 W while cycling at frequencies up to 160 strokes per minute.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us