Chemical storage bund treatment systems utilize digital bus communication to trigger neutralizing reagent feed when automated sump conductivity sensors detect chemical leakage. The inert fluoropolymer pump head provides broad chemical resistance across unexpected acid and alkaline chemical spills. Central plant safety systems transmit automated emergency dosing setpoints over serial bus cables to neutralize hazardous containment sumps safely.
Calibrated chemical metering provides stepped hydraulic output across operating pressure tiers: 20.0 L/h (0.33 L/Min) at 5 bar, 32.0 L/h (0.53 L/Min) at 4 bar, 62.0 L/h (1.03 L/Min) at 2 bar, and up to 110.0 L/h (1.83 L/Min) at 0.1 bar, with a stroke capacity of 1.11–6.11 cc/stroke. The wetted liquid end incorporates a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and EPDM seals, with a dry net weight of 4.4 kg (SEKO 2026 W&I Catalogue, p. 13). A standard PVDF installation kit is supplied, including a PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube.
Operating from a stabilized 100–240 VAC (50/60 Hz) switch-mode power supply with an energy draw of 29.0–37.0 W, the drive operates up to 300 strokes per minute using 8/10 mm plumbing connections. Supervisory network integration is powered by an RS485 Modbus RTU interface for PLC communication, supplemented by a 4-20 mA analogue input, pulse frequency input, batch dosing modes (ppm, 1:N, N:1, 1:1), timed feed, remote start/stop, mechanical stroke length knob, and a front backlit display.
The IP65 fiberglass-reinforced polypropylene housing protects internal components against airborne chemical vapors and low-pressure water washdown. Factory-sealed circular IP65 connectors allow all signal cables to wire directly into the exterior without casing disassembly. Standard mounting feet bolt directly onto dosing skids. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- Stepped hydraulic capacity delivering 20.0 L/h at 5 bar (50 m head) up to 110.0 L/h at 0.1 bar
- Stabilized 100–240 VAC (50/60 Hz) multi-voltage power supply drawing 29.0–37.0 W with up to 300 strokes per minute
- Wetted liquid end constructed with PVDF pump head, double ceramic check balls, PTFE diaphragm, and EPDM seals
- Solid PTFE diaphragm designed for chemical isolation and backed by official SEKO 5-year diaphragm guarantee
- Mechanical stroke length regulation knob for precise micrometer volumetric displacement tuning
- Integrated RS485 Modbus RTU interface for direct PLC supervision, 4-20 mA analogue input, pulse frequency control, and front backlit display
- Complete PVDF installation kit included (PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, 2 m PVDF delivery tube) for 8/10 mm connections
- Fiberglass-reinforced polypropylene IP65 enclosure with external circular connectors for closed-casing wiring
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 1.83 L/Min |
| Max Head | 50 m |
| Power | 0.037 kW / 240v |
| Suitable For | Alkaline CIP Cleaner Injection |
| Body Material | PVDF |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (8/10 mm) |
| Outlet Size | Hose Connection (8/10 mm) |
| Warranty | 24 Months |
Documents
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which dosing control features and operational adjustment methods belong to this pump?
Flow rate calibration for SEKO Tekba-R EMG 803 PVDF EPDM Modbus Solenoid Dosing Pump features an RS485 Modbus RTU interface for PLC supervision, alongside a 4-20 mA analogue input, pulse frequency input, batch dosing modes including proportional ppm and multiplier ratios, timed feed, remote start/stop, mechanical stroke length knob, and front backlit display.
What manufacturer warranty coverage and diaphragm policies apply to this chemical pump?
Official SEKO manufacturer warranty terms protect EMG803MNHH100M0, providing full equipment coverage against manufacturing defects—including a 5-year guarantee on the solid PTFE diaphragm—when installed in sheltered environments up to 40°C ambient temperature with chemically compatible fluids.
Which chemical injection throughput and system line pressure govern this pump?
Hydraulic delivery across EMG-803-MNHH-100M0 provides stepped positive displacement across operating tiers: 20.0 L/h or 0.33 L/Min at 5 bar, 32.0 L/h or 0.53 L/Min at 4 bar, 62.0 L/h or 1.03 L/Min at 2 bar, and up to 110.0 L/h or 1.83 L/Min at 0.1 bar, with a stroke capacity of 1.11–6.11 cc/stroke.
What electrical power parameters and running wattage draw apply to this chemical pump?
Running on a stabilized 100–240 VAC at 50/60 Hz switch-mode power supply, EMG 803 MNHH 100M0 consumes 29.0–37.0 W while pulsing the electromagnetic drive at up to 300 strokes per minute.
What wetted component materials and installation kit accompany this chemical pump?
Wetted liquid end construction on Tekba-R EMG 803 (EMG803MNHH100M0) combines a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and EPDM seals, and includes a complete PVDF installation kit with PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 8/10 mm connections.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us