Roll over image to zoom
SKU: EML603MNHH00000
SEKO Tekba-R EML 603 PVDF FKM-B Solenoid Dosing Pump
Australia-Wide
(08) 9240 2992
Official SEKO
Peace of Mind
Product Overview
Municipal sewage digesters utilize ferric salt delivery to precipitate dissolved phosphates and strip foul hydrogen sulfide odorous compounds. The heavy fluoropolymer liquid body withstands harsh ferric chloride attack while delivering steady chemical volumes into sludge streams. Plant operators adjust dosing output directly through analogue control dials to keep wastewater nutrient levels within licensed discharge parameters.
Electromagnetic positive displacement delivers stepped chemical injection across calibrated pressure tiers: 4.0 L/h (0.07 L/Min) at 12 bar, 5.0 L/h (0.08 L/Min) at 10 bar, 6.0 L/h (0.10 L/Min) at 8 bar, and up to 8.0 L/h (0.13 L/Min) at 2 bar, with a stroke capacity of 0.42–0.83 cc/stroke. The wetted liquid end incorporates a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, with a dry net weight of 3.4 kg (SEKO 2026 W&I Catalogue, p. 13). A standard PVDF installation kit is supplied, including a PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube.
Driven by a stabilized 100–240 VAC (50/60 Hz) switch-mode power supply drawing 17.0–22.0 W, the electromagnetic coil cycles at up to 160 strokes per minute. Liquid ports accommodate 4/6 mm tubing connections. Dual constant-flow regulation combines a rear-panel digital keyboard and display for stroke frequency setup with a mechanical micrometer knob for physical stroke length adjustment, alongside an external circular connector for a low-chemical level probe.
A fiberglass-reinforced polypropylene enclosure provides IP65 environmental protection against washdown spray and corrosive plant atmospheres. External circular IP65 connectors allow all power, signal, and control wiring to be completed without opening the pump casing. Integral mounting feet anchor directly to chemical tanks or skid baseplates. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- Stepped hydraulic capacity delivering 4.0 L/h at 12 bar (120 m head) up to 8.0 L/h at 2 bar
- Stabilized 100–240 VAC (50/60 Hz) multi-voltage power supply drawing 17.0–22.0 W with up to 160 strokes per minute
- Wetted liquid end constructed with PVDF pump head, double ceramic check balls, PTFE diaphragm, and FKM-B seals
- Solid PTFE diaphragm designed for chemical isolation and backed by official SEKO 5-year diaphragm guarantee
- Mechanical stroke length regulation knob for precise micrometer volumetric displacement tuning
- Rear-panel digital keyboard and display for stroke frequency configuration with level probe input
- Complete PVDF installation kit included (PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, 2 m PVDF delivery tube) for 4/6 mm connections
- Fiberglass-reinforced polypropylene IP65 enclosure with external circular connectors for closed-casing wiring
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 0.13 L/Min |
| Max Head | 120 m |
| Power | 0.022 kW / 240v |
| Suitable For | Acid pH Neutralization Systems |
| Body Material | PVDF |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (4/6 mm) |
| Outlet Size | Hose Connection (4/6 mm) |
| Warranty | 24 Months |
Documents
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
Which fluid path metallurgy and installation accessories accompany this pump?
Wetted liquid end construction on SEKO Tekba-R EML 603 PVDF FKM-B Solenoid Dosing Pump combines a chemical-resistant PVDF pump head with manual priming valve, double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, and includes a complete PVDF installation kit with PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
Which flow calibration methods and operational control interfaces belong to this pump?
Chemical feed adjustment across EML603MNHH00000 provides dual constant-flow regulation combining a rear-panel digital keyboard and display for frequency setup with a mechanical micrometer knob for physical stroke length adjustment, plus an external circular connector for a low-chemical level probe.
What factory equipment warranty and operational protection apply to this unit?
Equipment protection on EML-603-MNHH-00000 is backed by the official SEKO manufacturer warranty, which includes a 5-year guarantee on the solid PTFE diaphragm under standard sheltered plant installation conditions.
Which chemical dosing rate and discharge pressure parameters characterize this pump?
At maximum hydraulic throughput, the EML 603 MNHH 00000 delivers stepped chemical dosing across calibrated pressure tiers: 4.0 L/h or 0.07 L/Min at 12 bar, 5.0 L/h or 0.08 L/Min at 10 bar, 6.0 L/h or 0.10 L/Min at 8 bar, and up to 8.0 L/h or 0.13 L/Min at 2 bar, with a stroke capacity of 0.42–0.83 cc/stroke.
What electrical power characteristics and operational energy draw support this pump?
Operational energy demand across Tekba-R EML 603 (EML603MNHH00000) utilizes a stabilized 100–240 VAC at 50/60 Hz switch-mode connection drawing 17.0–22.0 W at stroke rates up to 160 strokes per minute.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us










