Roll over image to zoom
SKU: EML800MNAH00000
SEKO Tekba-R EML 800 Degassing PVDF FKM-B Solenoid Dosing Pump
Australia-Wide
(08) 9240 2992
Official SEKO
Peace of Mind
Product Overview
Poultry chilling operations depend on measured antimicrobial injection to disinfect bird wash water and maintain food processing hygiene standards. The self-venting liquid head eliminates gaseous air pockets caused by foaming sanitizing agents, sustaining fluid intake across fluctuating line pressures. Washdown technicians adjust chemical injection volumes quickly using clear faceplate knobs to fulfill rigorous food sanitation protocols.
Electromagnetic positive displacement delivers stepped chemical injection across calibrated pressure tiers: 6.3 L/h (0.11 L/Min) at 16 bar, 9.0 L/h (0.15 L/Min) at 10 bar, 13.5 L/h (0.23 L/Min) at 5 bar, and up to 16.2 L/h (0.27 L/Min) at 1 bar (reflecting the 10% auto-degassing bypass derating per the SEKO 2026 AUS Price List vs. standard head datasheet ratings of 7.0 to 18.0 L/h), with a stroke capacity of 0.39–1.00 cc/stroke. The wetted assembly integrates an auto-degassing PVDF pump head that automatically vents entrapped vapor bubbles, coupled with double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, with a dry net weight of 4.4 kg (SEKO 2026 W&I Catalogue, p. 13). A standard PVDF installation kit is supplied, including a PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube.
Operating from a stabilized 100–240 VAC (50/60 Hz) switch-mode power supply with an energy draw of 22.0–33.0 W, the drive operates up to 300 strokes per minute using 4/6 mm plumbing connections. Dual constant-flow regulation combines a rear-panel digital keyboard and display for stroke frequency setup with a mechanical micrometer knob for physical stroke length adjustment, alongside an external circular connector for a low-chemical level probe.
The IP65 fiberglass-reinforced polypropylene housing protects internal components against airborne chemical vapors and low-pressure water washdown. Factory-sealed circular IP65 connectors allow all signal cables to wire directly into the exterior without casing disassembly. Standard mounting feet bolt directly onto dosing skids. All units are backed by local Australian inventory and technical spare parts availability.
FEATURES
- Stepped hydraulic capacity delivering 6.3 L/h at 16 bar (160 m head) up to 16.2 L/h at 1 bar
- Stabilized 100–240 VAC (50/60 Hz) multi-voltage power supply drawing 22.0–33.0 W with up to 300 strokes per minute
- Wetted liquid end constructed with Degassing PVDF pump head, double ceramic check balls, PTFE diaphragm, and FKM-B seals
- Solid PTFE diaphragm designed for chemical isolation and backed by official SEKO 5-year diaphragm guarantee
- Mechanical stroke length regulation knob for precise micrometer volumetric displacement tuning
- Rear-panel digital keyboard and display for stroke frequency configuration with level probe input
- Complete PVDF installation kit included (PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, 2 m PVDF delivery tube) for 4/6 mm connections
- Fiberglass-reinforced polypropylene IP65 enclosure with external circular connectors for closed-casing wiring
- Warranty: Backed by official SEKO manufacturer warranty (including 5-year solid PTFE diaphragm guarantee) against manufacturing defects
SPECIFICATIONS
| Max Flow | 0.27 L/Min |
| Max Head | 160 m |
| Power | 0.033 kW / 240v |
| Suitable For | CIP Sanitation Chemical Injection |
| Body Material | Degassing PVDF |
| Liquid Temperature | Maximum 40°C |
| Inlet Size | Hose Connection (4/6 mm) |
| Outlet Size | Hose Connection (4/6 mm) |
| Warranty | 24 Months |
Warranty & Returns
All products supplied by Foundation Pumps are covered by a minimum 12-month warranty unless otherwise stated. Some brands may offer longer manufacturer warranties. Warranty covers manufacturing defects, faulty materials and workmanship under normal use.
- Products must be installed correctly and in accordance with the manufacturer’s instructions.
- Warranty does not cover incorrect installation, misuse, dry running, normal wear and tear, unauthorised repairs or damage caused by external factors.
- Proof of purchase, photos, videos and installation details may be requested when assessing a warranty claim.
- The customer is responsible for returning the product to Foundation Pumps or the nominated service centre unless otherwise agreed.
- Removal, reinstallation, labour and associated site costs are generally the customer’s responsibility unless required under Australian Consumer Law.
- Change-of-mind returns may be accepted within 30 days provided the product is unused, uninstalled and returned in its original packaging.
- Customers are responsible for return freight costs for change-of-mind returns.
- Restocking fees may apply to special-order, bulky or non-stocked products.
- Used, installed or specially ordered products may not be eligible for change-of-mind returns.
- If a product arrives damaged or faulty, please contact Foundation Pumps as soon as possible so we can assist with the appropriate repair, replacement or refund.
Your rights under Australian Consumer Law are not affected.
What fluid transfer throughput and delivery pressure are developed by this unit?
Calibrated chemical metering on SEKO Tekba-R EML 800 Degassing PVDF FKM-B Solenoid Dosing Pump generates positive displacement output across operating tiers: 6.3 L/h or 0.11 L/Min at 16 bar, 9.0 L/h or 0.15 L/Min at 10 bar, 13.5 L/h or 0.23 L/Min at 5 bar, and up to 16.2 L/h or 0.27 L/Min at 1 bar, reflecting the 10 percent auto-degassing bypass derating per the SEKO 2026 AUS Price List vs standard head datasheet ratings of 7.0 to 18.0 L/h, with a stroke capacity of 0.39–1.00 cc/stroke.
Which line voltage supply and electrical wattage demand are needed for this unit?
Electric power propulsion for EML800MNAH00000 operates on a stabilized 100–240 VAC at 50/60 Hz switch-mode supply drawing 22.0–33.0 W while cycling at frequencies up to 300 strokes per minute.
Which wetted component metallurgy and installation hardware are included for this pump?
Internal chemical contact components for EML-800-MNAH-00000 incorporate an auto-degassing PVDF pump head that automatically vents entrapped vapor bubbles, double ceramic check valve balls, a solid PTFE diaphragm, and FKM-B seals, and includes a complete PVDF installation kit with PVDF foot filter, PVDF injection valve, 4 m PVC suction/purge tube, and 2 m PVDF delivery tube for 4/6 mm connections.
Which dosing control modes and external communication options are built into this pump?
Flow rate calibration for EML 800 MNAH 00000 features dual constant-flow regulation combining a rear-panel digital keyboard and display for frequency setup with a mechanical micrometer knob for physical stroke length adjustment, plus an external circular connector for a low-chemical level probe.
What manufacturer warranty coverage and component protections apply across this unit?
Official SEKO manufacturer warranty terms protect Tekba-R EML 800 (EML800MNAH00000), providing full equipment coverage against manufacturing defects—including a 5-year guarantee on the solid PTFE diaphragm—when installed in sheltered environments up to 40°C ambient temperature with chemically compatible fluids.
Need help choosing the right pump?
Our team of pump experts are here to help you find the perfect solution for your application.
- Free expert advice
- Pump sizing & system recommendations
- Fast response — call or email us